Angiotensin converting enzyme (ACE) is not only a critical component in the renin-angiotensin system (RAS), but also suggested as an important mediator for immune response and activity, such as immune cell mobilization, metabolism, biogenesis of immunoregulatory molecules, etc. The chronic duration of cardiovascular diseases (CVD) has been increasingly considered to be triggered by uncontrolled pathologic immune reactions from myeloid cells and lymphocytes. Considering the potential anti-inflammatory effect of the traditional antihypertensive ACE inhibitor (ACEi), we attempt to elucidate whether ACE and its catalytically relevant substances as well as signaling pathways play a role in the immunity-related pathogenesis of common CVD, such as arterial hypertension, atherosclerosis and arrythmias.
View Article and Find Full Text PDFInt Immunopharmacol
September 2023
Cardiac remodeling is the final stage of almost all cardiovascular diseases, leading to heart failure and arrhythmias. However, the pathogenesis of cardiac remodeling is not fully understood, and specific treatment schemes are currently unavailable. Curcumol is a bioactive sesquiterpenoid that has anti-inflammatory, anti-apoptotic, and anti-fibrotic properties.
View Article and Find Full Text PDFThe behavior of vascular smooth muscle cells (VSMCs) contributes to the formation of neointima. We previously found that EHMT2 suppressed autophagy activation in VSMCs. BRD4770, an inhibitor of EHMT2/G9a, plays a critical role in several kinds of cancers.
View Article and Find Full Text PDFPrevention of neointima formation is the key to improving long-term outcomes after stenting or coronary artery bypass grafting. RNA N -methyladenosine (m A) methylation has been reported to be involved in the development of various cardiovascular diseases, but whether it has a regulatory effect on neointima formation is unknown. Herein, we revealed that methyltransferase-like 3 (METTL3), the major methyltransferase of m A methylation, was downregulated during vascular smooth muscle cell (VSMC) proliferation and neointima formation.
View Article and Find Full Text PDFBACKGROUND Angiopoietinlike protein 5 (ANGPTL5) is an adipocytokine and has an important role in metabolic processes including lipid metabolism, obesity, and type 2 diabetes mellitus. On the basis of these roles, the present study aimed to investigate the level and role of plasma ANGPTL5 in metabolic syndrome (MS) patients. MATERIAL AND METHODS A total of 139 participants was enrolled in this study; 69 of them were diagnosed with MS.
View Article and Find Full Text PDFBackground: Ischemic cardiomyopathy (ICM) resulting from coronary artery disease is a major cause of heart failure. The identification and quantification of differentially expressed proteins in patients with ICM may potentially lead to more effective diagnostic workup and treatment.
Aims: Liquid chromatography coupled to tandem mass spectrometry analysis was applied to identify differentially expressed proteins in individuals with ICM.
Objective Using coronary angiography and intravascular ultrasound methods to evaluate the performance of the novel fully bioabsorbable scaffold (NFBS) composed of poly-L-lactic acid/amorphous calcium phosphate (PLLA/ACP) at six-month follow-up by comparing with PLLA scaffolds Methods Twelve PLLA/ACP scaffolds and 12 PLLA scaffolds were implanted into the coronary arteries of 12 miniature pigs. Quantitative coronary angiography (QCA) was used to measure the reference vessel diameter (RVD), mean lumen diameter (MLD) and late lumen loss (LLL). According to IVUS images, we calculated the strut malapposition rate (SMR) at post implantation, strut overlap rate (SOR), reference vessel area (RVA), mean stent area (MSA), mean lumen area (MLA) and luminal patency rate (LPR) at six-month follow-up.
View Article and Find Full Text PDFTo study the effect of novel bioresorbable scaffold composed of poly-L-lactic acid (PLLA) and amorphous calcium phosphate (ACP) nanoparticles on inflammation and calcification of surrounding tissues after implantation. Ninety six PLLA/ACP scaffolds and 96 PLLA scaffolds were randomly implanted in the back muscle tissue of 48 SD rats. At the 1st, 2nd, 4th, and 12th weeks after implantation, the calcium, phosphorus, and alkaline phosphatase levels in the blood serum and the contents of calcium and alkaline phosphatase in the tissue surrounding the scaffolds were measured.
View Article and Find Full Text PDFSympathetic nerve and vagus nerve remodeling play an important part in cardiac function post-myocardial infarction (MI). Increasing evidence indicates that neuregulin-1 (NRG-1) improves cardiac function following heart failure. Since its impact on cardiac function and neural remodeling post-MI is poorly understood, we aimed to investigate the role of NRG-1 in autonomic nervous system remodeling post-MI.
View Article and Find Full Text PDFOur previous studies have confirmed the superior biocompatibility of the poly-L-lactic acid/amorphous calcium phosphate (PLLA/ACP) scaffolds (PowerScaffold) compared to PLLA scaffolds and their similar 6-month radial strength compared with TAXUS stents. In order to conduct further dynamic observations on the performance of the PowerScaffold after 12-month implantation compared with the TAXUS stents. Twenty PowerScaffold and 20 TAXUS were implanted in porcine coronary arteries.
View Article and Find Full Text PDFRationale: We reported previously, in porcine coronary arteries, that the novel biodegradable PowerStent Absorb paclitaxel-eluting stent had improved and sustained structural strength and functional performance at one month post-implantation.
Objective: To report the stent performance at 6-month follow-up.
Methods And Results: Six PowerStent Absorb and six TAXUS stents were randomly implanted in the left anterior descending and right coronary arteries of six Tibet miniature pigs.
Paclitaxel-coated balloons (PCBs) have become attractive alternative treatment options for patients with in-stent restenosis (ISR); however, the safety and efficacy of PCBs in comparison with those of conventional therapies are less well defined. The aim of this meta-analysis was to systematically review the efficacy and safety of PCBs for patients with ISR using comparisons with control groups. Electronic databases, such as MEDLINE, Embase and the Cochrane Central Register of Controlled Trials, were searched, and eligible studies that compared PCBs with uncoated balloons (UCBs) or drug-eluting stents (DESs) in patients with ISR were considered.
View Article and Find Full Text PDFCardiac fibroblast (CF) proliferation and transformation into myofibroblasts play important roles in cardiac fibrosis during pathological myocardial remodeling. In this study, we demonstrate that hepatocyte growth factor (HGF), an antifibrotic factor in the process of pulmonary, renal and liver fibrosis, is a negative regulator of cardiac fibroblast transformation in response to transforming growth factor‑β1 (TGF‑β1). HGF expression levels were significantly reduced in the CFs following treatment with 5 ng/ml TGF‑β1 for 48 h.
View Article and Find Full Text PDFBioabsorbable drug-eluting stents (BDES) offer multiple advantages over a permanent bare metal stent (BMS) for coronary artery disease (CAD). However, current BDES remains two major issues: inferior radial strength and biocompatibility. PowerStent Absorb BDES, fabricated by co-formulating amorphous calcium phosphate (ACP) nanoparticles with poly-L-lactic acid (PLLA/ACP, 98/2, w/w) and 2% Paclitaxel (PAX, w/w) was designed to address these issues.
View Article and Find Full Text PDFBiodegradable polymers used as vascular stent coatings and stent platforms encounter a major challenge: biocompatibility in vivo, which plays an important role in in-stent restenosis (ISR). Co-formulating amorphous calcium phosphate (ACP) into poly(lactic-co-glycolic acid) (PLGA) or poly-L-lactic acid (PLLA) was investigated to address the issue. For stent coating applications, metal stents were coated with polyethylene-co-vinyl acetate/poly-n-butyl methacrylate (PEVA/PBMA), PLGA or PLGA/ACP composites, and implanted into rat aortas for one and three months.
View Article and Find Full Text PDF