Background: Development of a non-hormonal long-acting reversible contraceptive for men could have a significant impact on reducing unintended pregnancies. Vasalgel™ is a high molecular weight polymer consisting of styrene-alt-maleic acid (SMA) dissolved in dimethyl sulfoxide being developed as a reversible male contraceptive device. It forms a hydrogel when implanted into the vasa deferentia, which prevents the passage of sperm.
View Article and Find Full Text PDFBackground: Vasectomy is currently the only long-acting contraceptive option available for men, despite increasing demand and potentially significant positive impacts on human health of additional male contraceptive options. Vasalgel ™ is a high molecular weight hydrogel polymer being developed as a non-hormonal long-acting reversible male contraceptive. Vasalgel consists of styrene-alt-maleic acid dissolved in dimethyl sulfoxide, which is distinct from styrene-alt-maleic anhydride materials previously studied.
View Article and Find Full Text PDFOn May 14, 1996, the U.S. Food and Drug Administration (FDA) issued a new regulation eliminating the establishment licensure requirement for certain 'specified' biologics and expanded the definition of 'manufacturer' for biologic products in general.
View Article and Find Full Text PDFA major problem faced by biomedical software developers and users is the complexity of the regulatory regimes confronting them. Of particular concern is whether, and to what extent, they are regulated by the Food and Drug Administration (FDA) and the consequences of such regulation. Producers, distributors, and users of biomedical software often are unaware that FDA regulates many of these products as medical devices.
View Article and Find Full Text PDFThe authors report a case of acute thioridazine (Melleril) poisoning with manifestations of polymorphous ventricular rhythm disturbances in the form of torsades de pointes, with an impaired conscious level. The opportunity is taken to review the electrocardiographic changes and cardiac complications linked to the quinidine-like effect of Melleril.
View Article and Find Full Text PDFA case study is presented in which the bronchial steal syndrome is demonstrated by stress thallium-201 myocardial perfusion imaging. The various aspects of the syndrome are discussed. We conclude that bronchial steal syndrome may provoke severe myocardial ischaemia even in the absence of coronary artery stenosis.
View Article and Find Full Text PDFArch Mal Coeur Vaiss
September 1988
A new case of late fracture of an outlet strut in a convexo-concave Björk-Shiley valve is reported. The fracture occurred 6 years after aortic implantation of the valve and was responsible for aorto-iliac embolization by the prosthetic disc and death of the patient from cardiogenic shock. This not uncommon complication of the Björk-Shiley valve prosthesis is usually ascribed to the relative fragility of its outlet strut welded to the metallic ring and subjected to strong pressures.
View Article and Find Full Text PDF