Transcatheter heart valve embolization is a serious and rare complication of transcatheter aortic valve replacement. Having a strategy for promptly managing transcatheter heart valve embolization is crucial to avoid emergency conversion from transcatheter aortic valve replacement to open-heart surgery. Many cases of transcatheter heart valve embolization occurring with balloon-expandable prostheses such as the SAPIEN 3 (Edwards LifeSciences Corporation) valve and self-expandable prostheses such as the ACURATE neo (Boston Scientific Corporation) valve have been reported in the literature.
View Article and Find Full Text PDFThrough these clinical cases, we present a new protocol of action, updated with the latest evidence on percutaneous pulmonary thrombectomy using dedicated catheters, for high-risk PE in pregnant women or during the early postpartum period.
View Article and Find Full Text PDFBackground: High-risk Pulmonary Embolism (PE) mortality remains very high. Systemic thrombolysis is effective but carries significant complications and contraindications related to the hemorrhagic risk. Percutaneous thrombectomy using aspiration catheters may be an alternative in patients with a high bleeding risk.
View Article and Find Full Text PDFThe usefulness of drug-eluting balloons (DEBs) has not been fully elucidated in calcified coronary lesions (CCLs). This meta-analysis aimed to evaluate the efficacy of DEBs compared to a drug-eluting stent (DES) in this setting. PubMed, EMBASE and Cochrane were searched through December 2023.
View Article and Find Full Text PDFJ Invasive Cardiol
October 2024
Background: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients.
Aims: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness.
Dynamic road-mapping (DRM) (Dynamic Coronary Roadmap; Philips) offers a real-time, dynamic overlay of the coronary tree on fluoroscopy.
View Article and Find Full Text PDFMechanical thrombectomy using a thromboaspiration catheter can be an effective alternative in the treatment of subacute pulmonary embolism.
View Article and Find Full Text PDFObjectives: The aim of this study was to analyze the efficacy and safety of percutaneous balloon pericardiotomy (PBP) in oncological patients who present with a malignant pericardial effusion (MPE).
Background: The use of PBP as a treatment for MPE is not standardized due to the limited evidence. Furthermore, the performance of a second PBP for a recurrence after a first procedure is controversial.
Microvasc Res
November 2023
In the 20th century, research focused on cholesterol and lipoproteins as the key mechanism in establishing atherosclerotic cardiovascular disease (ASCVD). Given that some studies demonstrated subclinical atherosclerosis in subjects without conventional cardiovascular risk factors, the elevated low-density lipoprotein (LDL) levels alone cannot account for the entire burden of atherosclerosis. Hence, large-scale clinical trials demonstrated the operation of immune and inflammatory pathways in ASCVD.
View Article and Find Full Text PDFCardiac computed tomography (CT) scan was performed in a 69-year-old male with atrial fibrillation radiofrequency ablation who was admitted for transcatheter angioplasty of left inferior pulmonary vein (LIPV) stenosis due to recurrent hemoptysis. CT showed complete ostial occlusion in the area of the LIPV. Occlusion of the pulmonary vein ostium is a rare complication.
View Article and Find Full Text PDFThere has been suggestion that vitamin D may play a role in protection against severe infection with COVID-19, defined as the need of intensive care unit admission. In this article a potential mechanism involving angiotensin-converting enzyme 2 (ACE2) is proposed.
View Article and Find Full Text PDFAn 86-year-old patient with non-valvular atrial fibrillation was referred to our institution to undergo a left atrial appendage (LAA) closure for recurrent gastrointestinal bleeding on direct oral anticoagulants. The transesophageal echocardiogram (TEE) performed the previous day evaluated the morphology and dimensions of the LAA and ruled out any thrombus. During the procedure, a pigtail catheter was inserted into the LAA, observing an unusual image we describe as a culde- sac, without an anomalous connection with any drainage in other vessel or cavity.
View Article and Find Full Text PDFTo the best of our knowledge, this case represents the first patient with Mitraclip, Amplatzer, and TricValve devices with a profound clinical improvement and long-term follow-up. In addition, this case illustrates how the treatment of high-risk patients with polyvalvular disease has changed in the last few years.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
February 2023
Coronary fistulas are not common in patients undergo coronary angiography. It is described, even less frequently, that coronary fistulas may be associated with giant aneurysms along their course. These cases classically are treated surgically.
View Article and Find Full Text PDF