Publications by authors named "Gabriele Miccoli"

Background: This study evaluated the gingival crevicular fluid (GCF) and Peri- implant crevicular fluid (PICF) concentrations of interleukin-1 beta (IL-1β), interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α) and active metalloproteinase-8 (a-MMP-8) in sites with healthy conditions vs. sites affected by periodontitis (PER) and peri-implantitis (PIM).

Methods: Periodontally healthy (PH) sites with PER, sites with peri-implant health (PIH), and sites with PIM were investigated intra-individually, according to the inclusion criteria of each group.

View Article and Find Full Text PDF

The aim of this retrospective study was to investigate the relationship between the amount of early bone remodeling, the marginal bone loss (MBL) progression, and the peri-implant sulcular fluid concentration of active metalloproteinase-8 (a-MMP-8) and the incidence of peri-implantitis (P) over 5 years of implant function. It has been documented that dental implants with a high degree of early marginal bone loss (MBL) are likely to achieve additional increased MBL during function. Moreover, it has been speculated that early increased MBL might be a predictive factor for the subsequent onset of peri-implant inflammatory diseases.

View Article and Find Full Text PDF

Background: The thorough knowledge of the anatomy of mandibular premolars is an essential factor for a correct approach to endodontic treatment, concerning both non-surgical and surgical treatment.

Objectives: Since there is no data on the Italian population in this context, the aim of this study was to evaluate, from a surgical perspective, the anatomy of mandibular premolars among the Italian population through a cone-beam computed tomography (CBCT) analysis, considering the morphology of their root canals according to Vertucci's classification and the prospect of their apices with regard to the vestibular bone plate and the proximity to the inferior alveolar nerve and the mental foramen as well as to evaluate the most appropriate distance from the apex in the radicular resection (3 mm or 5 mm).

Material And Methods: At total of 492 CBCT acquisitions (from 246 males and 246 females) were included retrospectively, evaluating 720 mandibular premolars.

View Article and Find Full Text PDF

Aim: To compare the clinical and radiographic conditions and the expression of pro-inflammatory cytokines in peri-implant crevicular fluid (PICF) at two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of loading.

Materials And Methods: In total, 20 single TP/BL implants and 20 contralateral OP/TL implants, both with a laser-microgrooved collar surface, in 20 systemically and periodontally healthy subjects (12 males and 8 females, between the age of 36 and 64 [mean age of 49.7 ± 12.

View Article and Find Full Text PDF

The main drawback of several studies is the limited analysis performed for the comparison of nickel-titanium (NiTi) rotary systems. Most often, research articles in this area are focalized on the static characteristics such as static cyclic fatigue, torsional loads, and flexibility, not considering their reciprocal interaction and all dynamic factors. Recent evidence in the literature defines the reciprocal interaction between these parameters as a fundamental element in the study of their mechanical characteristics.

View Article and Find Full Text PDF

Aim: The aim of the present study was to compare the direct and indirect cytotoxicity of a porcine dried acellular dermal matrix (PDADM) versus a porcine hydrated acellular dermal matrix (PHADM) in vitro. Both are used for periodontal and peri-implant soft tissue regeneration. Materials and methods: Two standard direct cytotoxicity tests—namely, the Trypan exclusion method (TEM) and the reagent WST-1 test (4-3-[4-iodophenyl]-2-[4-nitrophenyl]-2H-[5-tetrazolio]-1,3-benzol-desulphonated)—were performed using human primary mesenchymal stem cells (HPMSCs) seeded directly onto a PDADM and PHADM after seven days.

View Article and Find Full Text PDF

Since there are no reviews of the literature on this theme, the aim of this narrative review is to summarize the metallurgical tests used in endodontics, pointing out their functional use and their pros and cons and giving readers a user-friendly guide to serve as an orientation aid in the plethora of metallurgical tests. With this purpose, a literature search for articles published between January 2001 and December 2021 was conducted, using the electronic database PubMed to collect all published articles regarding the metallurgical tests used in endodontics for the evaluation of NiTi rotary instruments. The search was conducted using the following keywords: "metallurgy", "differential scanning calorimetry" (DSC), "X-ray diffraction" (XRD), "atomic force microscopy" (AFM), "energy-dispersive X-ray spectroscopy" (EDS), "focused ion beam analysis" (FIB) and "Auger electron spectroscopy" (AES) combined with the term "endodontics" or "NiTi rotary instruments".

View Article and Find Full Text PDF

Cone-beam computed tomography (CBCT) represents today the most widespread and most used 3D examination in dentistry. It is precise because of its usefulness in orthodontics and orthognathic surgery with large field of view (FOVs); in oral surgery and implantology for the 3D evaluation of bone volumes and proximity to noble structures; and in endodontics for the understanding of the often difficult root canal system anatomy with reduced FOV and greater resolution that this imaging technique, also considering the wide diffusion and availability in dental offices, in addition to the short examination execution times, allows its wide use..

View Article and Find Full Text PDF

(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future.

View Article and Find Full Text PDF

Objectives: To compare gingival tissue healing at surgically manipulated periodontal sites and at sites receiving implants and healing abutments with machined (MS) vs laser-microtextured (LMS) surface placed with one-stage protocol.

Material And Methods: Twenty-four non-smoking patients each received two implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one implant with a MS collar and one immediate healing abutment with a MS, and one implant with a LMS collar and one immediate healing abutment with a LMS were used.

View Article and Find Full Text PDF

Aim And Objective: The aim and objective of this study was to evaluate and compare the cutting efficacy of two different nickel titanium rotary instruments by a novel methodology: the operative torque (torque and time needed to progress toward the apex).

Materials And Methods: Ten fresh extracted upper first premolars with two canals were instrumented with a KaVo (Biberach, Germany) and a KaVo 1:1 handpiece at 300 rpm with maximum torque set at 2 N. One canal was instrumented with ProGlider NiTi rotary instruments (Dentsply Sirona Endodontics, Ballaigues, Switzerland), with tip size of 16.

View Article and Find Full Text PDF

Aim And Objective: The aim of this case report was to describe regenerative endodontic procedures (REPs) of the previously treated mature teeth with long-term results.

Background: Regenerative endodontic procedures are aimed to treat apical periodontitis and regenerate the pulp-dentin complex in necrotic teeth. However, there is no consensus in using REPs in the previously treated mature teeth.

View Article and Find Full Text PDF

Background: Repeated removal and replacement of healing abutments result in frequent injuries to the soft tissues.

Purpose: The purpose of this study was to evaluate the effect of disconnection/reconnection of laser microgrooved vs. machined healing and prosthetic abutments on clinical periodontal parameters, marginal bone levels, and proinflammatory cytokine levels around dental implants.

View Article and Find Full Text PDF

The aim of the present study was to retrospectively evaluate the longevity of teeth and implants during a long-term period in a cohort of periodontally compromised patients, treated and maintained in a private specialist periodontal practice, and to analyze the associated risk factors. Fifty-eight patients (30 men, 28 women) who had received active periodontal therapy (APT) and regular periodontal maintenance (PM) ≥ 10 years were included and evaluated. The following were evaluated: (1) statistically significant differences of clinical parameters assessed at six tooth or implant sites (plaque scores, bleeding score, periodontal probing depth, bleeding on probing, and gingival recession) and radiographic parameters (mesial and distal bone crest loss) between patients with and without tooth/implant loss during PM; and (2) associations between the number of teeth and implants lost and potential risk factors.

View Article and Find Full Text PDF

Objectives: To retrospectively evaluate the conditions of the peri-implant tissues in treated patients with chronic periodontitis (CP) and in patients without chronic periodontitis (noCP).

Materials And Methods: A chart review was used to evaluate 267 implants, 134 placed in 42 CP treated patients and 133 placed in 46 noCP patients. The primary outcome was to evaluate the condition of the peri-implant tissues (health, peri-mucositis, and peri-implantitis).

View Article and Find Full Text PDF

Torsional stresses are one of the most frequent causes of intracanal separation of nickel-titanium endodontic instruments, which represents a great concern of endodontists. For this reason, torsional resistance of rotary instruments has been deeply investigated by determining all parameters that can influenced it, that can be summarized in: (1) Tooth-related factors, (2) Strategy-related factors and (3) Instrument-related factors. This study was conducted to examine the influence of shaft length on torsional resistance of a nickel-titanium rotary instrument and if it should be considered as an Instrument-related factor.

View Article and Find Full Text PDF

Introduction: Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance.

Methods: Sixty S-One 20.

View Article and Find Full Text PDF

Aim: The aim of the present study was to take a survey on Italian practitioners concerning the perceived risks of aerosol contamination in COVID-19 times and their attitude toward modifications of treatment protocols to reduce this risk.

Materials And Methods: Power analysis calculated a minimum sample size of 150 participants at 99% confidence level with a 5% margin of error. To homogenize responses elicited by different preventive measures by various national governments, only Italian dentists were included in the survey: overall 500 responses were collected.

View Article and Find Full Text PDF

COVID-19 pandemic has strongly and rapidly affected routine lifestyle and consequently, dental business, practice, and education. During the pandemic period, most Governments worldwide made specific regulations or recommendations to close practices, to avoid non-urgent dental therapies and treat only dental emergencies. Some recent surveys showed how dentists perceived the COVID-19 risk and how they reacted: by modifying their way of working, by reducing aerosol producing procedures, by improving staff and patient's safety with the increased use of personal protective equipment, environmental disinfection and limited access to dental offices, increasing use of remote consulting and triage.

View Article and Find Full Text PDF

Aim: The aim of the present study is twofold: to evaluate cyclic fatigue resistance differences of two different nickel-titanium rotary instruments, brand new and after an instrumentation of single root extracted teeth.

Materials And Methods: Twenty new S One 20.06 were randomly divided into two groups.

View Article and Find Full Text PDF

Aim: The present study was conducted to assess the perceived risk of COVID-19 transmission in dental professionals (DPs), that include dentists and dental auxiliary staffs, and whether rapid tests should be a recommended tool to constrain the transmission of the COVID-19, and who should be bearing their cost (governments, dentists, or patients) through an online survey.

Materials And Methods: A sample size of = 700 was recruited in the study. The study included DPs from all over the world.

View Article and Find Full Text PDF

The purpose of this study is to describe the Minimally Invasive Intraoral Approach (MIIA) performed on selected cases of abscesses and neck phlegmons of odontogenic origin when the infection has not spread beyond the inferior mandibular margin. This technique allows us to avoid cervicotomy by a direct approach to the abscess, draining it through the oral cavity. If the limits have already been crossed, then cervicotomy is necessary.

View Article and Find Full Text PDF

Aim: The aim of the present study was to investigate the role of the flat design compared with a non-flat designed instrument on the centering ability in a simulated root canal system.

Materials And Methods: Two file systems were chosen: the F-One (Fanta Dental, Shanghai, China) and a prototype with the same design but without the flat-side design. A total of 50 simulated L-shaped root canals in resin blocks were shaped with a new instrument each.

View Article and Find Full Text PDF

Endodontic treatments tend to have very high successful rates in spite of the fact that they are quite an invasive, difficult procedure, especially in complex anatomies. Some complications can arise during or after a root canal procedure due to poor understanding of the anatomy and iatrogenic errors mainly during instrumentation. While some of these problems can be anticipated, many can never really be predicted.

View Article and Find Full Text PDF

In the last decades, the use of nickel-titanium (Ni-Ti) rotary instruments has become the most effective and popular method among endodontists for shaping root canals, even if there are still concerns regarding the increased risks of intracanal breakage or weakening of the instruments. So manufacturers started to modify the cross-sectional geometrical aspects of the files in order to improve their resistance to torsional and cyclic fatigue. Design is a major feature in determining instruments' properties including cutting efficiency, removal of debris, stresses generated during instrumentation, and the relative resistance to these stresses; however, a perfect design is not existing and any change in design is likely to provide some advantages but also some disadvantages.

View Article and Find Full Text PDF