Publications by authors named "Gabriele Bolle"

Purpose: The accelerometer-based system is a portable surgical navigation system for TKA that does not require the use of a large computer console for registration and alignment feedback as required in computer-assisted surgery (CAS). The purpose of this prospective study was to determine the accuracy of the accelerometer-based system in the tibial component positioning and also to evaluate clinical outcomes.

Methods: Between December 2011 and July 2012, a total of 53 consecutive patients with primary gonarthrosis were prospectively enrolled for unilateral TKA using a handheld surgical navigation system to perform the tibial resection.

View Article and Find Full Text PDF

Purpose: The aim of this study is to evaluate the accuracy of a patient-specific instrumentation (PSI) as assessed by the intraoperative use of knee navigation software during the surgical procedure.

Methods: Fifteen patients with primary gonarthrosis were selected for unilateral total knee arthroplasty. The first three patients were excluded from this study, as they were considered to be a warm up to set-up the procedure.

View Article and Find Full Text PDF

Purpose: The aim of this study is to evaluate the accuracy of VISIONAIRE (Smith & Nephew Inc., Memphis, TN, USA) Patient Matched cutting tibial jigs in comparison with extramedullary (EM) tibial instrumentation by analysing data as detected by intra-operative use of VectorVision knee navigation software from BrainLAB (Redwood City, CA, USA).

Methods: Twelve patients were selected for unilateral total knee replacement (TKR).

View Article and Find Full Text PDF