Publications by authors named "Gabriela Eugenia Iacobescu"

This paper presents the fabrication and characterization of plane capacitors utilizing magnetodielectric materials composed of magnetizable microfibers dispersed within a silicone oil matrix. The microfibers, with a mean diameter of about 0.94 μm, comprise hematite (α-FeO), maghemite (γ-FeO), and magnetite (FeO).

View Article and Find Full Text PDF

Reducing the impact of some biological fluids on bioimplants involves the control of surface characteristics by modeling the interface architecture and assembling ecofriendly thin films to retard corrosion. Therefore, a mixture of hydrolyzed keratin peptides (HKER) was investigated as a corrosion inhibitor for 304L stainless steel (SS) in physiological serum (PS), using electrochemical measurements associated with optical microscopy and atomic force microscopy (AFM). The tests, performed for various concentrations of the inhibitor at different temperatures, showed that the inhibition efficiency () decreased with a rise in temperature and proportionally increased with the HKER concentration, reaching its maximum level, around 88%, at 25 °C, with a concentration of 40 g L HKER in physiological serum.

View Article and Find Full Text PDF

Over the past few decades, tactile sensors have become an emerging field of research with direct applications in the area of biomedical engineering. New types of tactile sensors, called magneto-tactile sensors, have recently been developed. The aim of our work was to create a low-cost composite whose electrical conductivity depends on mechanical compressions that can be finely tuned using a magnetic field for magneto-tactile sensor fabrication.

View Article and Find Full Text PDF

In this paper, we report the preparation of two new composite materials based on cotton fibers and magnetic liquid consisting of magnetite nanoparticles and light mineral oil. Using the composites and two simple textolite plates plated with copper foil assembled with self-adhesive tape, electrical devices are manufactured. By using an original experimental setup, we measured the electrical capacitance and the loss tangent in a medium-frequency electric field superimposed on a magnetic field.

View Article and Find Full Text PDF

In the present work, we report that the manufacturing of new environmentally friendly and low-cost materials with electrical conductivity can be roughly and finely tuned by an external magnetic field for technical and biomedical applications. With this aim in mind, we prepared three types of membranes based on cotton fabric impregnated with bee honey, carbonyl iron microparticles (CI), and silver microparticles (SmP). In order to study the influence of the metal particles and the magnetic field on the electrical conductivity of membranes, electrical devices were made.

View Article and Find Full Text PDF

In this paper, we present the procedure for fabricating a new magneto-tactile sensor (MTS) based on a low-cost commercial polyurethane sponge, including the experimental test configuration, the experimental process, and a description of the mechanisms that lead to obtaining the MTS and its characteristics. It is shown that by using a polyurethane sponge, microparticles of carbonyl iron, ethanol, and copper foil with electroconductive adhesive, we can obtain a high-performance and low-cost MTS. With the experimental assembly described in this paper, the variation in time of the electrical capacity of the MTS was measured in the presence of a deforming force field, a magnetic field, and a magnetic field superimposed over a deformation field.

View Article and Find Full Text PDF

In this study, magnetizable polyurethane sponges (MSs) were obtained from commercial absorbent polyurethane sponges (PSs) doped with carbonyl iron microparticles (CIPs). Based on MSs, we manufactured cylindrical capacitors (CCs). The CCs were subjected to both a magnetic field and an alternating electric field, with a frequency of f=1 kHz.

View Article and Find Full Text PDF

In this paper, we study the electrical properties of new hybrid magnetorheological suspensions (hMRSs) and propose a theoretical model to explain the dependence of the electric capacitance on the iron volumetric fraction, ΦFe, of the dopants and on the external magnetic field. The hMRSs, with dimensions of 30 mm×30 mm×2 mm, were manufactured based on impregnating cotton fabric, during heating, with three solutions of iron microparticles in silicone oil. Flat capacitors based on these hMRSs were then produced.

View Article and Find Full Text PDF

Poly (vinyl butyral-co-vinyl alcohol-co-vinyl acetate) named further PVBA was investigated as a protective coating for copper corrosion in 0.9% NaCl solution using electrochemical measurements such as, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization associated with atomic force microscopy (AFM). The PVBA coating on the copper surface (Cu-PVBA) was modeled in methanol containing PVBA.

View Article and Find Full Text PDF