Publications by authors named "Gabriel Guterres Marmitt"

In recent years, synthetic Computed Tomography (CT) images generated from Magnetic Resonance (MR) or Cone Beam Computed Tomography (CBCT) acquisitions have been shown to be comparable to real CT images in terms of dose computation for radiotherapy simulation. However, until now, there has been no independent strategy to assess the quality of each synthetic image in the absence of ground truth. In this work, we propose a Deep Learning (DL)-based framework to predict the accuracy of synthetic CT in terms of Mean Absolute Error (MAE) without the need for a ground truth (GT).

View Article and Find Full Text PDF

Background And Purpose: Model-based selection of proton therapy patients relies on a predefined reduction in normal tissue complication probability (NTCP) with respect to photon therapy. The decision is necessarily made based on the treatment plan, but NTCP can be affected when the delivered treatment deviates from the plan due to delivery inaccuracies. Especially for proton therapy of lung cancer, this can be important because of tissue density changes and, with pencil beam scanning, the interplay effect between the proton beam and breathing motion.

View Article and Find Full Text PDF

Background: Proton radiography (PR) uses highly energetic proton beams to create images where energy loss is the main contrast mechanism. Water-equivalent path length (WEPL) measurements using flat panel PR (FP-PR) have potential for in vivo range verification. However, an accurate WEPL measurement via FP-PR requires irradiation with multiple energy layers, imposing high imaging doses.

View Article and Find Full Text PDF

Background: Time-resolved 4D cone beam-computed tomography (4D-CBCT) allows a daily assessment of patient anatomy and respiratory motion. However, 4D-CBCTs suffer from imaging artifacts that affect the CT number accuracy and prevent accurate proton dose calculations. Deep learning can be used to correct CT numbers and generate synthetic CTs (sCTs) that can enable CBCT-based proton dose calculations.

View Article and Find Full Text PDF

Purpose: Adaptive proton therapy (APT) of lung cancer patients requires frequent volumetric imaging of diagnostic quality. Cone-beam CT (CBCT) can provide these daily images, but x-ray scattering limits CBCT-image quality and hampers dose calculation accuracy. The purpose of this study was to generate CBCT-based synthetic CTs using a deep convolutional neural network (DCNN) and investigate image quality and clinical suitability for proton dose calculations in lung cancer patients.

View Article and Find Full Text PDF

Objective: Proton range uncertainties can compromise the effectiveness of proton therapy treatments. Water equivalent path length (WEPL) assessment by flat panel detector proton radiography (FP-PR) can provide means of range uncertainty detection. Since WEPL accuracy intrinsically relies on the FP-PR calibration parameters, the purpose of this study is to establish an optimal calibration procedure that ensures high accuracy of WEPL measurements.

View Article and Find Full Text PDF

Cone-beam computed tomography (CBCT)- and magnetic resonance (MR)-images allow a daily observation of patient anatomy but are not directly suited for accurate proton dose calculations. This can be overcome by creating synthetic CTs (sCT) using deep convolutional neural networks. In this study, we compared sCTs based on CBCTs and MRs for head and neck (H&N) cancer patients in terms of image quality and proton dose calculation accuracy.

View Article and Find Full Text PDF

This study evaluates the suitability of convolutional neural networks (CNNs) to automatically process proton radiography (PR)-based images. CNNs are used to classify PR images impaired by several sources of error affecting the proton range, more precisely setup and calibration curve errors. PR simulations were performed in 40 head and neck cancer patients, at three different anatomical locations (fields A, B and C, centered for head and neck, neck and base of skull coverage).

View Article and Find Full Text PDF

Purpose: Patient specific quality assurance (PSQA) is required to verify the treatment delivery and the dose calculation by the treatment planning system (TPS). The objective of this work is to demonstrate the feasibility to substitute resource consuming measurement based PSQA (PSQA) by independent dose recalculations (PSQA), and that PSQA results may be interpreted in a clinically relevant manner using normal tissue complication probability (NTCP) and tumor control probability (TCP) models.

Methods And Materials: A platform for the automatic execution of the two following PSQA workflows was implemented: (i) using the TPS generated plan and (ii) using treatment delivery log files (log-plan).

View Article and Find Full Text PDF

In-room imaging is a prerequisite for adaptive proton therapy. The use of onboard cone-beam computed tomography (CBCT) imaging, which is routinely acquired for patient position verification, can enable daily dose reconstructions and plan adaptation decisions. Image quality deficiencies though, hamper dose calculation accuracy and make corrections of CBCTs a necessity.

View Article and Find Full Text PDF

The relative biological effectiveness (RBE) of protons is highly variable and difficult to quantify. However, RBE is related to the local ionization density, which can be related to the physical measurable dose weighted linear energy transfer (LET). The aim of this study was to validate the LET calculations for proton therapy beams implemented in a commercially available treatment planning system (TPS) using microdosimetry measurements and independent LET calculations (Open-MCsquare (MCS)).

View Article and Find Full Text PDF

Non-planar Fin Field Effect Transistors (FinFET) are already present in modern devices. The evolution from the well-established 2D planar technology to the design of 3D nanostructures rose new fabrication processes, but a technique capable of full characterization, particularly their dopant distribution, in a representative (high statistics) way is still lacking. Here we propose a methodology based on Medium Energy Ion Scattering (MEIS) to address this query, allowing structural and compositional quantification of advanced 3D FinFET devices with nanometer spatial resolution.

View Article and Find Full Text PDF