Background: Idiopathic pulmonary fibrosis (IPF) is a progressive, deadly lung disease with several factors, including respiratory tract infections (RTI), for disease worsening. There's no comprehensive data on RTI incidence in IPF patients across different therapies, including antifibrotic (nintedanib or pirfenidone), investigative or placebo treatments.
Methods: A systematic search of databases Medline, EMBASE, Cochrane Central, Web of Science and Scopus was conducted on September 30th 2024 (PROSPERO registration number: CRD42023484213).
J Clin Med
November 2024
Aims: Suboptimal device programming is frequent in non-responders to cardiac resynchronization therapy (CRT). However, the role of device optimization and the most appropriate technique are still unknown. The aim of our study was to analyse the effect of different CRT optimization techniques within a network meta-analysis.
View Article and Find Full Text PDFAims: Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm.
Methods And Results: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145).
Background: Kidney dysfunction (KD) is a main limiting factor of applying guideline-directed medical therapy (GDMT) and reaching the recommended target doses (TD) in heart failure (HF) with reduced ejection fraction (HFrEF).
Hypothesis: We aimed to assess the success of optimization, long-term applicability, and adherence of neurohormonal antagonist triple therapy (TT:RASi [ACEi/ARB/ARNI] + βB + MRA) according to the KD after a HF hospitalization and to investigate its impact on prognosis.
Methods: The data of 247 real-world, consecutive patients were analyzed who were hospitalized in 2019-2021 for HFrEF and then were followed-up for 1 year.
(1) Background: Besides the use of guideline-directed medical therapy (GDMT), multidisciplinary heart failure (HF) outpatient care (HFOC) is of strategic importance in HFrEF. (2) Methods: Data from 257 hospitalised HFrEF patients between 2019 and 2021 were retrospectively analysed. Application and target doses of GDMT were compared between HFOC and non-HFOC patients at discharge and at 1 year.
View Article and Find Full Text PDFAims: This study aimed to investigate the impact of cardiac resynchronization therapy with a defibrillator (CRT-D) on mortality, comparing it with CRT with a pacemaker (CRT-P). Additionally, the study sought to identify subgroups, evaluate the time trend in treatment effects, and analyze patient characteristics, considering the changing indications over the past decades.
Methods And Results: PubMed, CENTRAL, and Embase up to October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on mortality.
Introduction: Renal dysfunction is a main limiting factor of applying and up-titrating guideline-directed medical therapy (GDMT) among patients with heart failure with reduced ejection fraction (HFrEF).
Objective: Our retrospective monocentric observational study aimed to analyse the application ratio of combined neurohormonal antagonist therapy (RASi: ACEI/ARB/ARNI + βB + MRA) and 12-month all-cause mortality differences in terms of renal dysfunction among HFrEF patients hospitalized for heart failure.
Method: We retrospectively analysed the cohort of consecutive HFrEF patients, hospitalized at the Heart Failure Unit of our tertiary cardiological centre in 2019-2021.
Background And Aims: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain.
Methods: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio.
CIED, cardiac implantable electronic devices; CRT, cardiac resynchronization therapy; CRT-D, cardiac resynchronization therapy defibrillator; EA, electroanatomical; ICD, implantable cardioverter defibrillator; LBB, left bundle branch; LBBAP, left bundle branch area pacing; LV, left ventricular; LVEF, left ventricular ejection fraction; NT-proBNP, N-terminal pro-B-type natriuretic peptide; MRI, cardiac magnetic resonance imaging; S-ICD, subcutaneous defibrillator.
View Article and Find Full Text PDFIntroduction: Hospitalization due to heart failure (HF) progression is associated with poor prognosis. This highlights the role of the implementation of guideline-directed medical therapy (GDMT) in improving the morbidity and mortality of patients with heart failure with reduced ejection fraction (HFrEF). There are limited data about the intrahospital applicability of GDMT in real-world circumstances.
View Article and Find Full Text PDFAims: The BUDAPEST-CRT Upgrade study is the first prospective, randomized, multicentre clinical trial investigating the outcomes after cardiac resynchronization therapy (CRT) upgrade in heart failure (HF) patients with intermittent or permanent right ventricular (RV) pacing with wide paced QRS. This report describes the baseline clinical characteristics of the enrolled patients and compares them to cohorts from previous milestone CRT studies.
Methods And Results: This international multicentre randomized controlled trial investigates 360 patients having a pacemaker (PM) or implantable cardioverter defibrillator (ICD) device for at least 6 months prior to enrolment, reduced left ventricular ejection fraction (LVEF ≤35%), HF symptoms (New York Heart Association [NYHA] functional class II-IVa), wide paced QRS (>150 ms), and ≥20% of RV pacing burden without having a native left bundle branch block.
Aims: This study aims to characterize the range of implantable device-based sensor values including heart sounds, markers of ventilation, thoracic impedance, activity, and heart rate for patients with heart failure (HF) when patients were deemed to be in clinically stable periods against the time course of acute decompensation and recovery from HF events.
Methods And Results: The MultiSENSE trial followed 900 patients implanted with a COGNIS CRT-D for up to 1 year. Chronic, ambulatory diagnostic sensor data were collected and evaluated during clinically stable periods (CSP: unchanged NYHA classification, no adverse events, and weight change ≤2.
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed.
View Article and Find Full Text PDFBackground: Recently published studies suggested that digoxin may increase mortality in heart failure with reduced ejection fraction (HFrEF). However, in the vast majority of former trials serum digoxin concentration (SDC) was not measured and therapy was not SDC-guided.
Aim: To assess the impact of SDC-guided digoxin therapy on mortality in HFrEF patients.
Introduction: The novel two-lead cardiac resynchronization therapy (CRT)-DX system utilizes a floating atrial dipole on the implantable cardioverter-defibrillator lead, and when implanted with a left ventricular (LV) lead, offers a two-lead CRT system with AV synchrony. This study compared complication rates and CRT response among subjects implanted with a two-lead CRT-DX system to those subjects implanted with a standard three-lead CRT-D system.
Methods And Results: A total of 240 subjects from the Sentus QP-Extended CRT Evaluation with Quadripolar Left Ventricular Leads postapproval study were selected to identify 120 matched pairs based on similar demographic characteristics using a Greedy algorithm.
Aims: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial.
Methods And Results: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group).
Background: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory.
Objective: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center.
Methods: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016.
Purpose: Pneumothorax (PTX) following cardiac implantable electronic device procedures is traditionally treated with chest tube drainage (CTD). We hypothesized that, in a subset of patients, the less invasive needle aspiration (NA) may also be effective. We compared the strategy of primary NA with that of primary CTD in a single-center observational study.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
June 2019
Background: The use of quadripolar (QP) left ventricular leads for cardiac resynchronization therapy (CRT) is intended to improve outcomes compared with conventional bipolar leads (BP). Hence, the number of implanted quadripolar CRT systems is increasing despite limited long-term data.
Purpose: The aim of this study is to evaluate clinical response and long-term outcomes of CRT recipients who were implanted with quadripolar versus bipolar left ventricular leads.
Objectives: This study sought to report periprocedural outcomes and intermediate-term follow-up of hemodialysis patients undergoing Micra implantation.
Background: Leadless pacemakers may be preferred in patients with limited vascular access and high-infection risk, such as patients on hemodialysis.
Methods: Patients on hemodialysis at the time of Micra implantation attempt (n = 201 of 2,819; 7%) from the Micra Transcatheter Pacing Study investigational device exemption trial, Micra Transcatheter Pacing System Continued Access Study Protocol, and Micra Transcatheter Pacing System Post-Approval Registry were included in the analysis.