In this paper, the surface acoustic wave velocity results acquired from the inspection of specially manufactured and characterised alumina ceramic materials are presented. Ultrasonic velocity data of alumina-based ceramics in the range 60-100% theoretical density was generated utilising non-contacting laser-ultrasonic measurements based on laser generation and detection of surface acoustic waves with the objective of creating a routine technique for industrial advanced alumina inspection. With linear fitting the surface acoustic wave velocity data serves as a calibration graph for using laser ultrasonics for routine monitoring of alumina.
View Article and Find Full Text PDF