Publications by authors named "G T Gullberg"

We present a new method to measure sub-microcurie activities of photon-emitting radionuclides in organs and lesions of small animals in vivo. Our technique, named the collimator-less likelihood fit, combines a very high sensitivity collimatorless detector with a Monte Carlo-based likelihood fit in order to estimate the activities in previously segmented regions of interest along with their uncertainties. This is done directly from the photon projections in our collimatorless detector and from the region of interest segmentation provided by an x-ray computed tomography scan.

View Article and Find Full Text PDF

In our previous work on image reconstruction for single-layer collimatorless scintigraphy, we developed the min-min weighted robust least squares (WRLS) optimization algorithm to address the challenge of reconstructing images when both the system matrix and the projection data are uncertain. Whereas the WRLS algorithm has been successful in two-dimensional (2D) reconstruction, expanding it to three-dimensional (3D) reconstruction is difficult since the WRLS optimization problem is neither smooth nor strongly-convex. To overcome these difficulties and achieve robust image reconstruction in the presence of system uncertainties and projection noise, we propose a generalized iterative method based on the maximum likelihood expectation maximization (MLEM) algorithm, hereinafter referred to as the Masked-MLEM algorithm.

View Article and Find Full Text PDF

Background: Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available.

Purpose: With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator.

View Article and Find Full Text PDF

In vivo imaging of Ac is a major challenge in the development of targeted alpha therapy radiopharmaceuticals due to the extremely low injected doses. In this paper, we present the design of a multi-modality gamma camera that integrates both proximity and Compton imaging in order to achieve the demanding sensitivities required to image Ac with good image quality. We consider a dual-head camera, each of the heads consisting of two planar cadmium zinc telluride detectors acting as scatterer and absorber for Compton imaging, and with the scatterer practically in contact with the subject to allow for proximity imaging.

View Article and Find Full Text PDF

Attenuation correction (AC) is important for accurate interpretation of SPECT myocardial perfusion imaging (MPI). However, it is challenging to perform AC in dedicated cardiac systems not equipped with a transmission imaging capability. Previously, we demonstrated the feasibility of generating attenuation-corrected SPECT images using a deep learning technique (SPECT) directly from non-corrected images (SPECT).

View Article and Find Full Text PDF