Background: Mixed venous oxygen saturation (SvO 2 ) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO 2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO 2 ), against gold standard CO-oximetry.
Methods: Capno-SvO 2 was compared to SvO 2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges.
Aim: Periprocedural and postinterventional care of patients undergoing closure of patent foramen ovale (PFO) varies significantly across care providers. Same-day discharge (SDD) after transcatheter interventions is an evolving concept. This study aimed to assess the same-day discharge rate and incidence of complications in patients undergoing PFO closure with intracardiac echocardiography (ICE) using the Gore®Cardioform Septal Occluder (GSO) device.
View Article and Find Full Text PDFBackground: ECG abnormalities have been linked to adverse changes in right ventricular (RV) morphology and poor clinical outcomes in repaired Tetralogy of Fallot (rTOF). Our aim was to describe how ECG changes progress in early and intermediate follow-up and whether types of surgical strategy at the time of primary repair affected these changes.
Methods: We studied patients with rTOF born 2000-2018 operated at our institution.
Enzyme-constrained genome-scale models (ecGEMs) have potential to predict phenotypes in a variety of conditions, such as growth rates or carbon sources. This study investigated if ecGEMs can guide metabolic engineering efforts to swap anaerobic redox-neutral ATP-providing pathways in yeast from alcoholic fermentation to equimolar co-production of 2,3-butanediol and glycerol. With proven pathways and low product toxicity, the ecGEM solution space aligned well with observed phenotypes.
View Article and Find Full Text PDFAim: To describe our initial experience with the indications and results of the 5/7 Occlutech® duct Occluder (ODO, Occlutech International AB, Helsingborg, Sweden). A small incremental increase in occluder sizes is of utmost importance for successful outcomes, especially in smaller patients in whom protrusion of the distal disk towards the aorta should be minimised.
Methods: Retrospective study of all patients undergoing PDA closure with the 5/7 ODO in three institutions since 2018.