Unlabelled: The accuracy of an automated quantitative analysis of same-day rest/stress 99mTc sestamibi SPECT images for detection and localization of coronary artery disease (CAD) was assessed in a multicenter trial consisting of 161 patients from 7 different clinical sites utilizing various camera computer systems.
Methods: Of the 161 patients, 102 had angiographically documented coronary artery disease, 22 had normal coronary arteriograms, and 37 had a low (< 5%) likelihood of coronary artery disease based on their age, sex, symptoms and the results of their exercise electrocardiograms. The patients were studied using previously optimized image acquisition and processing protocols.
Unlabelled: Separate or simultaneous rest 201Tl/stress 99mTc-sestamibi dual-isotope SPECT are potentially efficient myocardial perfusion imaging protocols which combine the use of a high-resolution 99mTc tracer for stress perfusion assessment and 201Tl, the current single-photon agent of choice, for viability assessment.
Methods: To investigate the feasibility of dual-isotope myocardial perfusion SPECT protocols using rest 201Tl and stress sestamibi, 201Tl crosstalk into the 99mTc acquisition window (Group 1, n = 26 patients) and 99mTc crosstalk into 201Tl windows (Group 2, n = 25) were studied. For Group 1, treadmill exercise with sestamibi injection and poststress SPECT ("virgin" sestamibi images) were performed, followed by rest 201Tl injection and SPECT acquisition using dual-isotope windows (contaminated or "dual" images).
Gender-matched stress normal limits and criteria for abnormality for rest-stress 99mTc-sestamibi same-day myocardial perfusion imaging were developed and validated in 160 patients who were imaged using previously developed optimized acquisition, processing and quantitative protocols. The gender-matched mean and standard deviation of the normal response were calculated using 35 male and 25 female patients with a < 5% likelihood of coronary artery disease. Receiver-operating curve analysis using expert visual interpretation as the "gold standard" was used to determine the optimal criteria for abnormality detection, in terms of standard deviations from the mean and minimum defect size for each of the four major zones of the polar map, in a pilot population consisting of an additional 35 male and 25 female patients with a variety of perfusion defects.
View Article and Find Full Text PDFThe relation between the quantitative myocardial perfusion defect severity of exercise thallium-201 single-photon emission computed tomography (SPECT) and the quantitative degree of coronary stenosis was examined in 18 patients with 1-vessel disease (> or = 50% diameter stenosis), and abnormal thallium-201 SPECT. A total of 26 vessels were analyzed. Thallium-201 SPECT quantitative defect severity score was derived by summing the number of pixels in a coronary territory in which counts fell below the normal mean and multiplied by the number of SDs by which they fell below the normal mean.
View Article and Find Full Text PDFProne 201Tl myocardial perfusion SPECT has been shown to improve left ventricular inferior wall counts compared to supine imaging, thus minimizing diaphragmatic attenuation. Prone SPECT quantitative normal limits were developed and prospectively applied to 36 patients who had coronary angiography. The prone imaging table used had a cut-out under cardiac area which increased the average myocardial counts by 10.
View Article and Find Full Text PDF