Introduction: This paper is a report of an ICSH review of policies and practices for internal quality control (IQC) policy for haematology cell counters among regulatory bodies, cell counter manufacturers and diagnostic laboratories. It includes a discussion of the study findings and links to separate ICSH guidance for such policies and practices. The application of internal quality control (IQC) methods is an essential pre-requisite for all clinical laboratory testing including the blood count (Full Blood Count, FBC, or Complete Blood Count, CBC).
View Article and Find Full Text PDFThis paper is a description of the ICSH guidance for internal quality control (IQC) policy for blood cell counters. It follows from and links to a separate ICSH review for such policies and practices. The ICSH has gathered information regarding the current state of practice through review of published guidance from regulatory bodies, a questionnaire to six major cell counter manufacturers and a survey issued to 191 diagnostic laboratories in four countries (China, the Republic of Ireland, Spain, and the United Kingdom) on their IQC practice and approach to the use of commercial IQC materials.
View Article and Find Full Text PDFBackground: Harmonization in laboratory medicine is essential for consistent and accurate clinical decision-making. There is significant and unwarranted variation in reference intervals (RIs) used by laboratories for assays with established analytical traceability. The Canadian Society of Clinical Chemists (CSCC) Working Group on Reference Interval Harmonization (hRI-WG) aims to establish harmonized RIs (hRIs) for laboratory tests and support implementation.
View Article and Find Full Text PDFObjective: The BD Vacutainer® Barricor™ plasma blood collection tube uses a mechanical separator during centrifugation to separate plasma from the cellular elements of blood. Compared to use of plasma separator tubes (PST™) with gel, Barricor™ produces a cleaner sample with less residual cellular content. We sought to determine if Barricor™ reduces pre-analytical error compared to PST™.
View Article and Find Full Text PDFBackground: Serial differences between intrapatient consecutive measurements can be transformed into Taylor series of variation vs time with the intersection at time = 0 (y0) equal to the total variation (analytical + biological + preanalytical). With small preanalytical variation, y0, expressed as a percentage of the mean, is equal to the variable component of the reference change value (RCV) calculation: (CVA2 + CVI2)1/2.
Methods: We determined the between-day RCV of patient data for 17 analytes and compared them to healthy participants' RCVs.