Background: The aim of this study was to compare the outcome of implantation of a XEN45 Gel Stent with the outcome of implantation of a Preserflo MicroShunt in a matched-pair analysis in eyes being naïve to filtering surgery.
Methods: In this comparative, retrospective study, 50 eyes that had undergone XEN45 Gel Stent implantation were compared with 50 eyes after Preserflo implantation. Follow-up was at least 6 months, and surgical success was measured by criteria A (IOP < 21 mmHg, IOP reduction >20%, no repeat surgery); criteria B (IOP < 18 mmHg, IOP reduction >20%, no repeat surgery); and criteria C (IOP ≤15 mmHg, IOP reduction ≥40%, no repeat surgery).
Purpose: To determine differing outcomes among either phakic or pseudophakic patients who received standalone XEN45 Gel Stent (Allergan, an AbbVie Company, CA, USA) implantation and patients who underwent combined surgery with phacoemulsification.
Methods: This retrospective single-center study involved 180 eyes of 180 participants who underwent XEN45 Gel Stent implantation, of which 60 eyes received combined surgery with phacoemulsification (combined group). Standalone stent implantation was performed on 60 phakic (phakic group) and on 60 pseudophakic eyes (pseudophakic group).
Background: To investigate in combined iStent inject implantation with phacoemulsification carried out bilaterally, whether intraocular pressure (IOP)-lowering effectiveness in the first eye has a predictive potential for the outcome of the second eye in primary open-angle glaucoma (POAG).
Methods: This retrospective study included 72 eyes from 36 participants, who underwent trabecular bypass implantation in combination with cataract surgery at two study centres (Düsseldorf, Cologne). Surgery was classified as either 'success' or 'failure' based on three scores: IOP at follow-up <21 mmHg (Score A) or IOP < 18 mmHg (Score B), with an IOP reduction >20% respectively, without re-surgery and IOP ≤ 15 mmHg with an IOP reduction ≥40%, without re-surgery (Score C).
Background/purpose: To determine anatomical success and best-corrected visual acuity after secondary surgery with heavy silicone oil tamponade in patients with persistent full-thickness macular holes.
Methods: In this retrospective study, 63 eyes with persistent full-thickness macular holes after primary pars plana vitrectomy and internal limiting membrane peeling underwent secondary surgery with heavy silicone oil tamponade. Macular spectral domain optical coherence tomography and best-corrected visual acuity measurements were performed during the follow-up.
: Visual prostheses, epiretinal stimulating arrays, are a promising therapy in treating retinal dystrophies and degenerations. In the wake of a new generation of devices, an innovative method for epiretinal fixation of stimulator arrays is required. We present the development of tailor-made bioadhesive peptides (peptesives) for fixating epiretinal stimulating arrays omitting the use of traumatic retinal tacks.
View Article and Find Full Text PDF