Publications by authors named "G Meliado"

This large multicenter study of 37 magnetic resonance imaging scanners aimed at characterizing, for the first time, spatial profiles of inaccuracy (namely, Δ-profiles) in apparent diffusion coefficient (ADC) values with varying acquisition plan orientation and diffusion weighting gradient direction, using a statistical approach exploiting unsupervised clustering analysis. A diffusion-weighted imaging (DWI) protocol (b-value: 0-200-400-600-800-1000 s mm) with different combinations of acquisition plan orientation (axial/sagittal/coronal) and diffusion weighting gradient direction (anterior-posterior/left-right/feet-head) was acquired on a standard water phantom. For each acquisition setup, Δ-profiles along the 3 main orthogonal directions were characterized by fitting data with a second order polynomial function ().

View Article and Find Full Text PDF

Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain.

View Article and Find Full Text PDF

Purpose: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation.

Methods: Water phantom acquisitions were carried out on 39 scanners.

View Article and Find Full Text PDF

Objectives: To test whether 3 T multiparametric magnetic resonance imaging (mMRI) provides information related to molecular subtypes of breast cancer.

Methods: Women with mammographic or US findings of breast lesions (BI-RADS 4-5) underwent 3 T mMRI (DCE, DWI and MR spectroscopy). The histological type of breast cancer was assessed.

View Article and Find Full Text PDF

Purpose: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI).

Materials And Methods: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study.

View Article and Find Full Text PDF