Hippocampal-sparing radiotherapy (HSR) is a promising approach to alleviate cognitive side effects following cranial radiotherapy. Microstructural brain changes after irradiation have been demonstrated using Diffusion Tensor Imaging (DTI). However, evidence is conflicting for certain parameters and anatomic structures.
View Article and Find Full Text PDFPurpose: A markerless workflow for the treatment of breast cancer patients has been introduced and evaluated retrospectively. It includes surface-guided radiation therapy (SGRT)-only positioning for patients with small cone beam CT (CBCT) position corrections during the first five fractions. Prerequisites and the frequency of its clinical application were evaluated, as well as potential benefits in terms of treatment time and dose savings, the frequency of CBCT scans, and the accuracy of the positioning.
View Article and Find Full Text PDFJ Appl Clin Med Phys
October 2021
Purpose: The goal of this study was to investigate how the choice of the region of interest (ROI) affects the registration results of surface imaging for daily positioning of breast cancer patients.
Methods: The AlignRT system (VisionRT, London) and the XVI Cone beam CT (CBCT; Elekta, Stockholm) installed on two Versa HD linacs (Elekta) were used in this study, which included 28 patients (160 fractions). In the clinical workflow, patients were prepositioned with AlignRT and then shifted in 6 degrees of freedom (DOF) according to the CBCT.
During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient's anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements.
View Article and Find Full Text PDFModern radiotherapy of female breast cancers often employs high dose rate brachytherapy, where a radioactive source is moved inside catheters, implanted in the female breast, according to a prescribed treatment plan. Source localization relative to the patient's anatomy is determined with solenoid sensors whose spatial positions are measured with an electromagnetic tracking system. Precise sensor dwell position determination is of utmost importance to assure irradiation of the cancerous tissue according to the treatment plan.
View Article and Find Full Text PDF