Publications by authors named "G I Tous"

A method using a combination of asymmetric flow field-flow fractionation (AFFFF) and multiangle light scattering (MALS) techniques has been shown to improve the estimation of virus particle counts and the amount of aggregated virus in laboratory samples. The method is based on the spherical particle counting approach given by Wyatt and Weida in 2004, with additional modifications. The new method was tested by analyzing polystyrene beads and adenovirus samples, both having a well-characterized particle size and concentration.

View Article and Find Full Text PDF

Adequate biophysical characterization of influenza virions is important for vaccine development. The influenza virus vaccines are produced from the allantoic fluid of developing chicken embryos. The process of viral replication produces a heterogeneous mixture of infectious and non-infectious viral particles with varying states of aggregation.

View Article and Find Full Text PDF

We have identified a single tryptophan (Trp) residue responsible for loss of binding and biological activity upon ultraviolet (UV) light irradiation in MEDI-493, a humanized monoclonal antibody (MAb) against respiratory syncytial virus (RSV). This finding provides a better understanding of structure-function relationship in a 150-kDa protein. Irradiation of MEDI-493 with UV light resulted in spectral changes typical of Trp photoproducts and in a progressive loss of MEDI-493 binding and biological activity as measured by ELISA, Biacore, and cell-based assays.

View Article and Find Full Text PDF

In this paper, the steps required to validate a liquid chromatography peptide mapping method with mass spectrometric detection (LC-MS) for use as an identity test and characterization tool are presented. All aspects of peptide mapping are evaluated and optimized, including protein sample preparation (protein reduction, alkylation and enzymatic digestion), high performance liquid chromatography (HPLC) separation of the resulting peptides, and the use of a mass spectrometric detection. In addition, the validation of a single quadruple MS detector is described and the implementation of on-line electrospray ionization MS (ESI-MS) as an adjunct detector to support the investigation of peak differences is presented.

View Article and Find Full Text PDF

A novel, nonreducible thioether bridge between the light and heavy chains of different IgG1 monoclonal antibodies has been characterized. An additional band with an apparent molecular weight of 92 kDa was detected when monoclonal antibodies were analyzed by reducing capillary gel electrophoresis (rCGE) and reducing SDS-PAGE. To further investigate this observation, an early-eluting peak in the size exclusion chromatogram of a reduced and alkylated monoclonal antibody was collected and characterized by liquid chromatography, mass spectrometry, and gel electrophoresis.

View Article and Find Full Text PDF