In February 1981, a measles outbreak occurred in a pediatric practice in DeKalb County, GA. The source case, a 12-year-old boy vaccinated against measles at 11 1/2 months of age, was in the office for one hour on the second day of rash, primarily in a single examining room. On examination, he was noted to be coughing vigorously.
View Article and Find Full Text PDFA three-year epidemic of legionnaires' disease in a hospital was dramatically curtailed following hyperchlorination of the potable water supply. The hypothesis that potable water was the source for the outbreak was further supported by isolation of Legionella pneumophila (the agent of legionnaires' disease) from the hospital water supply, observation that a sudden upsurge had occurred in the number of cases following a peculiar manipulation of the hospital water system, and documentation of a 30-fold increase in concentration of organisms in the water when this manipulation was artificially recreated. Thus, potable water may be an important source of epidemic legionnaires' disease and continuous hyperchlorination a method of control.
View Article and Find Full Text PDFAm J Infect Control
February 1985
Some aspects of ventilation and air conditioning have been explained for infection control personnel who are not engineers. With more understanding of ventilation, infection control personnel may be able to communicate better with engineering personnel on this subject.
View Article and Find Full Text PDF