Publications by authors named "G Entine"

Objectives: Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments.

View Article and Find Full Text PDF

Purpose: To determine if wrapping instruments in conjunction with full-cycle steam sterilization affects the incidence of postoperative infection in patients undergoing ophthalmic surgery in a dedicated eye center.

Design: Retrospective, consecutive-case, comparative study.

Methods: Two consecutive groups, each of approximately 19 000 ophthalmic surgical patients, were reviewed for postoperative infection.

View Article and Find Full Text PDF

Polychromatic flow cytometry enables detailed identification of cell phenotype using multiple fluorescent parameters. The photomultiplier tubes (PMTs) used to detect fluorescence in current instruments limit the sensitivity in the long wavelength spectral range. We demonstrate the flow cytometric applications of silicon avalanche photodiodes (APDs), which have improved red sensitivity and a working fluorescence detection range beyond 1,000 nm.

View Article and Find Full Text PDF

We explore dual-ended read out of LSO arrays with two position sensitive avalanche photodiodes (PSAPDs) as a high resolution, high efficiency depth-encoding detector for PET applications. Flood histograms, energy resolution and depth of interaction (DOI) resolution were measured for unpolished LSO arrays with individual crystal sizes of 1.0, 1.

View Article and Find Full Text PDF
Article Synopsis
  • The paper discusses the development of a high-resolution positron emission tomography (PET) detector module utilizing a lutetium oxyorthosilicate scintillator array and position-sensitive avalanche photodiodes (PSAPDs) for improved performance.
  • The study presents key performance metrics, including Depth of Interaction (DOI) resolution of 3-4 mm FWHM, energy resolution averaging 14% FWHM, and coincidence timing resolution of 4.5 ns FWHM.
  • These results align with design objectives, indicating the module's suitability for applications in small animal and breast imaging.
View Article and Find Full Text PDF