Aim: The objective of this study was to assess marginal bone level around single implants inserted in fresh extraction sockets in the anterior maxillary region and instantly restored with computer-aided design/computer-aided manufacturing customized temporary crowns cemented on the final abutment.
Materials And Methods: A total of 20 patients (15 females and 5 males, with a mean age of 30 years), where 20 were placed in fresh extraction sockets. After raising a full-thickness flap, atraumatic extraction was performed the implant site was prepared and fixtures were stabilized on the palatal bone wall.
J Long Term Eff Med Implants
August 2022
Is to measure the peripheral and internal gap at the implant-abutment interface of an implant system connected to its original or compatible non-original abutments. Twenty implants were assembled with four different types of abutments having the same conical internal interface. All abutments were considered compatible with Tx Astra Tech Implant SystemTM.
View Article and Find Full Text PDFPurpose: The effect of masticatory loads on the retention of overdenture attachments is poorly documented. The aim of this in vitro study is to assess the effect of simulated mastication on the retentive properties and dimensions of Locator inserts.
Materials And Methods: 30 specimens simulating nonanatomic edentulous flat ridges with two implant replicas each were fabricated.
Purpose: Limited information is currently available relative to the effect of masticatory loads on the retentive properties of Locator attachments. The aims of this in vitro study were to assess and compare the effect of simulated mastication on the retention of white, pink, and blue Locator inserts for overdentures retained by 2 implants.
Materials And Methods: Thirty specimens simulating a nonanatomic edentulous flat ridge with two implants and an overdenture were divided into 3 groups according to the color of the fitted insert: transparent clear group (n = 10), pink group (n = 10), and blue group (n = 10).
Leakage has been addressed as a major contributing factor to inflammatory reactions at the implant-abutment connection, leading to problems such as oral malodor, inflammation, and marginal bone loss. The aim of this study was to investigate in vitro the leakage at implant-abutment interface of OsseoSpeed™ implants connected to original and compatible abutments. A total of 28 OsseoSpeed implants were divided into four groups (n = 7).
View Article and Find Full Text PDF