Environ Health Perspect
October 1994
Exposure to 2,4-difluoroaniline (DFA) was monitored by GC-MS of DFA adducts bound to hemoglobin (Hb). In two studies, involving 20 and 16 workers potentially exposed to low concentrations of DFA, median concentrations of 10 (range 1-83) and 20 (range 4-322) pmole/g Hb were found, respectively. For better interpretation of these results, the in vivo binding of DFA to Hb was investigated.
View Article and Find Full Text PDFIn two studies, involving 75 and 72 workers, potential exposure to 3-chloro-4-fluoroaniline (CFA) was biologically monitored by determination of its main urinary metabolite 2-amino-4-chloro-5-fluorophenol sulfate (CFA-S). As this method only allows the detection of recent exposure, analysis of CFA adducts bound to hemoglobin (Hb) was investigated as a method that allows biological monitoring of exposure to CFA over longer periods. The median CFA-S concentration in 67 samples from the first study was 0.
View Article and Find Full Text PDFRecently, the determination of S-phenylmercapturic acid (S-PMA) in urine has been proposed as a suitable biomarker for the monitoring of low level exposures to benzene. In the study reported here, the test has been validated in 12 separate studies in chemical manufacturing plants, oil refineries, and natural gas production plants. Parameters studied were the urinary excretion characteristics of S-PMA, the specificity and the sensitivity of the assay, and the relations between exposures to airborne benzene and urinary S-PMA concentrations and between urinary phenol and S-PMA concentrations.
View Article and Find Full Text PDFEnviron Health Perspect
March 1993
In a study on workers in a chemical plant where ethylene oxide (EtO) is manufactured and partly used for ethylene glycol production, exposure to EtO was monitored during annual periodic health assessments in January 1988, December 1988, and March 1990 by the determination of the level of 2-hydroxyethylvaline (HOEtVal) in hemoglobin. The HOEtVal levels in workers corresponded with the potential EtO exposures. The highest level was found in December 1988, in blood samples collected 1-2 months after a shut-down, maintenance, and start-up program.
View Article and Find Full Text PDFHemoglobin adducts are useful for the identification and quantification of electrophilic agents in vivo. A modified Edman degradation method has been extensively used for monitoring exposure to ethylene oxide through gas chromatographic-mass spectrometric measurements of hydroxyethyl adducts to the N-terminal valines in hemoglobin. In a ring test, four laboratories using different versions of the method analyzed eight human globin samples with low adduct levels from ethylene oxide.
View Article and Find Full Text PDF