Musculoskelet Surg
October 2018
Purpose: Glenoid fractures occur as a result of direct impact of the humeral head against the glenoid rim following high-energy trauma. They frequently involve one-third of the glenoid surface with an oblique fracture rim from 2 to 6-7 o'clock, and they must not be confused with bony Bankart lesions. In medium-age patients, they are frequently associated with acute cuff tear while in older patients with chronic cuff tear: These conditions increase the instability of the shoulder if not treated.
View Article and Find Full Text PDFBackground: The humerus shaft is one of the sites with the largest probability of developing pseudoarthrosis after fracture. We present the results of nine patients with atrophic pseudoarthrosis of humeral shaft treated with angular stability plate associated with allograft and platelet-rich plasma (PRP), after a first treatment with intramedullary nail to correct the fracture.
Material And Methods: From January 2012 to December 2014, nine patients were treated for atrophic pseudoarthrosis (PSA) of humeral shaft treated previously using intramedullary nail; seven humeral diaphysis fractures were located in the middle-proximal third and two in the middle third.
Post-traumatic shoulder instability is a frequent condition in active population, representing one of most disabling pathologies, due to altered balance involving joints. No data are so far available on early ultrastructural osteo-chondral damages, associated with the onset of invalidating pathologies, like osteoarthritis-OA. Biopsies of glenoid articular cartilage and sub-chondral bone were taken from 10 adult patients underwent arthroscopic stabilization.
View Article and Find Full Text PDFObjective: To compare clinical outcomes and complication rates in the medium-to-long-term follow-up of Hertel 7 humeral head fractures treated with two different locking plates.
Materials And Methods: A total of 52 patients with type 7 humeral head fracture (in accordance with Hertel classification) were enrolled retrospectively: 24 patients [4 male, 20 female; mean age (standard deviation [SD]): 68.9 (5.
Musculoskelet Surg
September 2015
Background: Locking plate fixation is a reliable treatment for many displaced proximal humeral fractures. Carbon fiber-reinforced-poly-ether-ether-ketone (CFR-PEEK) plates have recently been introduced as an alternative to traditional metallic plates.
Methods: In a multicenter study involving the Orthopedic Services of 6 Italian hospitals, 182 patients with a proximal humeral fracture were treated with a Diphos H (Lima Corporate, San Daniele del Friuli, Italy) CFR-PEEK plate, 160 of whom were followed clinically and radiographically for 2 years or more.