Simultaneous measurement of X-ray ptychography and fluorescence microscopy allows high-resolution and high-sensitivity observations of the microstructure and trace-element distribution of a sample. In this paper, we propose a method for improving scanning fluorescence X-ray microscopy (SFXM) images, in which the SFXM image is deconvolved via virtual single-pixel imaging using different probe images for each scanning point obtained by X-ray ptychographic reconstruction. Numerical simulations confirmed that this method can increase the spatial resolution while suppressing artifacts caused by probe imprecision, e.
View Article and Find Full Text PDFPtychographic coherent diffraction imaging (CDI) allows the visualization of both the structure and chemical state of materials on the nanoscale, and has been developed for use in the soft and hard X-ray regions. In this study, a ptychographic CDI system with pinhole or Fresnel zone-plate optics for use in the tender X-ray region (2-5 keV) was developed on beamline BL27SU at SPring-8, in which high-precision pinholes optimized for the tender energy range were used to obtain diffraction intensity patterns with a low background, and a temperature stabilization system was developed to reduce the drift of the sample position. A ptychography measurement of a 200 nm thick tantalum test chart was performed at an incident X-ray energy of 2.
View Article and Find Full Text PDFA series of natural circular dichroism (CD) and absorption spectra for films of α-aliphatic amino acids--such as alanine, aminobutyric acid, norvaline, norleucine, valine, leucine, and isoleucine--in the vacuum ultraviolet (VUV) region were observed with the absolute values of optical constants at the undulator-based CD beamline TERAS BL5. Preliminary predictions of some CD spectra were also performed, based on quantum-chemical calculations using the crystal structure. Although the absorption spectra show similar features to each other, significant differences between the CD spectra were found, especially in the 7-8 eV region.
View Article and Find Full Text PDFNatural circular dichroism (CD) spectra in the extreme ultraviolet (EUV) region down to a wavelength of 80 nm have been observed for the first time, using an alanine thin film deposited on sodium salicylate coated glass as a sample. Calibrated EUV-CD spectra of L-alanine exhibited a large negative peak at around 120 nm and a positive CD signal below 90 nm, which were roughly predicted by theoretical calculations. A CD measurement system with an Onuki-type polarizing undulator was used to obtain the EUV-CD spectra.
View Article and Find Full Text PDFAn accurate calibration method in which an ac-modulated polarizing undulator is used for polarization modulation spectroscopy such as circular dichroism (CD) and linear dichroism (LD) has been proposed and successfully applied to vacuum ultraviolet (vuv) CD and LD spectra measured at beamline BL-5B in the electron storage ring, TERAS, at AIST. This calibration method employs an undulator-modulation spectroscopic method with a multireflection polarimeter, and it uses electronic and optical elements identical to those used for the CD and LD measurements. This method regards the polarimeter as a standard sample for the CD and LD measurements in the vuv region in which a standard sample has not yet been established.
View Article and Find Full Text PDFWe have designed a compact optical cell for studying the absorption and circular dichroism (CD) of a solution sample in the vacuum ultraviolet (VUV) region using a temperature control unit. The cell size was 34 mm in diameter and 14 mm in length. Such compactness was obtained by coating the VUV scintillator onto the outside of the back window.
View Article and Find Full Text PDFPolarization modulation spectroscopy using an Onuki-type undulator is a useful technique for circular dichroism study in the vacuum-ultraviolet region. We have been developing the vacuum-ultraviolet circular dichroism (vuv-CD) spectroscopy in TERAS BL5 beamline at AIST. This paper describes recent improvements in our instrumentation and methods of analysis to achieve precise and absolute measurements.
View Article and Find Full Text PDFWe have developed an improved circular dichroism (CD) and linear dichroism (LD) simultaneous measurement system for the vacuum ultraviolet (VUV) region by polarization modulation techniques using a four-period Onuki-type crossed undulator as a polarized light source. The system has been constructed at the VUV beamline BL-5 in the electron storage ring TERAS, at AIST. Our improvements, in particular the adoption of an optical chopper as the detection method of incident light, have resulted in a flat baseline and a consequent simplification of the Mueller matrix calculation for our optical system.
View Article and Find Full Text PDF