Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2009
In this report, we summarize the survey of diagnostic X-ray equipment conducted in 2005, focusing on exposure conditions. What we would like to point out in this report is how prevalent digital image receptor systems have become, including flat panel detectors (FPD), which did not exist in our last survey five years ago. FPD have become popular very quickly among the digital receptor systems used in general radiography.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2009
In accordance with a questionnaire survey of diagnostic X-ray equipment enforced in 2005, this report was focused mainly on a photography device. The paper questionnaire was mailed to 667 institutions, and the collection rate was 20.4%.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
July 2003
Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
August 2002
X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%.
View Article and Find Full Text PDFThe X-ray Systems Study Group, in an attempt to determine the current status and changes in the state of X-ray equipment, reception systems, and equipment control, conducted investigational research by distributing a questionnaire survey to 400 facilities. The rate of recovery was 33%. The capacity of transformers has been increasing in spite of the three-phase 415 V decrease in the power supply of X-ray equipment.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
April 2002
The X-ray systems study group used the Victoreen NERO mAx model 8000, a new non-invasive X-ray output analyzer, to measure the tube voltage, tube voltage waveform, tube current, and irradiation time for conditions corresponding to general radiography and mammography. The measurement results were then compared with those obtained using a conventional invasive measuring instrument. The peak values of the tube voltage measured by the NERO mAx and the invasive measuring instrument were compared.
View Article and Find Full Text PDFIn an attempt to clarify the involvement of fatty acid desaturases (FADs) in the freezing tolerance of Chlorella vulgaris IAM C-27, developed by hardening, we have isolated cDNA clones for two types of FADs from the Chlorella strain, based on the sequence information of genes for delta12 and omega-3 FADs, respectively desaturating oleic acid (18:1) to linoleic acid (18:2) and linoleic acid (18:2) to linolenic acid (18:3). The deduced amino acid sequence of the first clone, designated CvFad2, showed about 66% similarity to the microsomal delta12 FADs from several higher plants and this gene had delta12 FAD activity when expressed in Saccharomyces cerevisiae. The predicted protein encoded by a second gene, designated CvFad3, showed about 60% similarity to the microsomal and plastidial omega-3 FADs from several higher plants.
View Article and Find Full Text PDF