Recent advances in the field of monodisperse microbubble synthesis by flow focusing allow for the production of foam-free, highly concentrated and monodisperse lipid-coated microbubble suspensions. It has been found that in vitro, such monodisperse ultrasound contrast agents (UCAs) improve the sensitivity of contrast-enhanced ultrasound imaging. Here, we present the first in vivo study in the left ventricle of rat and pig with this new monodisperse bubble agent.
View Article and Find Full Text PDFInitial reports from the 1960s describing the observations of ultrasound contrast enhancement by tiny gaseous bubbles during echocardiographic examinations prompted the development of the first ultrasound contrast agent in the 1980s. Current commercial contrast agents for echography, such as Definity, Optison, Sonazoid and SonoVue, have proven to be successful in a variety of on- and off-label clinical indications. Whereas contrast-specific technology has seen dramatic progress after the introduction of the first approved agents in the 1990s, successful clinical translation of new developments has been limited during the same period, while understanding of microbubble physical, chemical and biologic behavior has improved substantially.
View Article and Find Full Text PDFUltrasound contrast agents (UCAs) have opened up immense diagnostic possibilities by combined use of indicator dilution principles and dynamic contrast-enhanced ultrasound (DCE-US) imaging. UCAs are microbubbles encapsulated in a biocompatible shell. With a rheology comparable to that of red blood cells, UCAs provide an intravascular indicator for functional imaging of the (micro)vasculature by quantitative DCE-US.
View Article and Find Full Text PDFMonodisperse phospholipid-coated ultrasound contrast agent (UCA) microbubbles can be directly synthesized in a lab-on-a-chip flow-focusing device. However, high total lipid concentrations are required to minimize on-chip bubble coalescence. Here, we characterize the coalescence probability and the long-term size stability of microbubbles formed using DPPC and DSPC based lipid mixtures as a function of temperature.
View Article and Find Full Text PDFThe acoustic response of phospholipid-coated microbubble ultrasound contrast agents (UCA) is dramatically affected by their stabilizing shell. The interfacial shell elasticity increases the resonance frequency, the shell viscosity increases damping, and the nonlinear shell viscoelasticity increases the generation of harmonic echoes that are routinely used in contrast-enhanced ultrasound imaging. To date, the surface area-dependent interfacial properties of the phospholipid coating have never been measured due to the extremely short time scales of the MHz frequencies at which the microscopic bubbles are driven.
View Article and Find Full Text PDFResonantly driven monodisperse phospholipid-coated microbubbles are expected to substantially increase the sensitivity and efficiency in contrast-enhanced ultrasound imaging and therapy. They can be produced in a microfluidic flow-focusing device, but questions remain as to the role of the device geometry, the liquid and gas flow, and the phospholipid formulation on bubble stability. Here, we develop a model based on simple continuum mechanics equations that reveals the scaling of the coalescence probability with the key physical parameters.
View Article and Find Full Text PDFObjectives: To compare physicochemical characteristics and in vitro and in vivo contrast-enhanced ultrasound imaging performance of 3 commercially available ultrasound contrast agents: SonoVue (Bracco Imaging SpA, Colleretto Giacosa, Italy; also marketed as Lumason in the USA), Definity (Lantheus Medical Imaging, North Billerica, MA) and Optison (GE Healthcare AS, Oslo, Norway).
Methods: Physicochemical characteristics were measured with a Multisizer Coulter Counter (Beckman Coulter, Fullerton, CA). Two ultrasound systems (Aplio 500; Toshiba Medical Systems Corp, Tochigi-ken, Japan; and Logiq E9; GE Healthcare, Little Chalfont, England) were used with different transducers.
Ultrasound molecular imaging (USMI) is an emerging technique to monitor diseases at the molecular level by the use of novel targeted ultrasound contrast agents (tUCA). These consist of microbubbles functionalized with targeting ligands with high-affinity for molecular markers of specific disease processes, such as cancer-related angiogenesis. Among the molecular markers of angiogenesis, the vascular endothelial growth factor receptor 2 (VEGFR2) is recognized to play a major role.
View Article and Find Full Text PDFObjective: To investigate the value of dynamic contrast-enhanced (DCE)-ultrasonography (US) and software-generated parametric maps in predicting biopsy outcome and their potential to reduce the amount of negative biopsy cores.
Materials And Methods: For 651 prostate biopsy locations (82 consecutive patients) we correlated the interpretation of DCE-US recordings with and without parametric maps with biopsy results. The parametric maps were generated by software which extracts perfusion parameters that differentiate benign from malignant tissue from DCE-US recordings.
Purpose Of Review: An imaging tool providing reliable prostate cancer (PCa) detection and localization is necessary to improve the diagnostic pathway with imaging targeted biopsies. This review presents the latest developments in existing and novel ultrasound modalities for the detection and localization of PCa.
Recent Findings: The ultrasound modalities that were very promising on introduction (HistoScanning and Doppler) have shown a wane in performance when tested in larger patient populations.
Ultrasound is a real-time imaging technique which is widely used in many clinical applications for its capacity to provide anatomic information with high spatial and temporal resolution. The advent of ultrasound contrast agents in combination with contrast-specific imaging modes has given access to perfusion assessments at an organ level, leading to an improved diagnostic accuracy. More recently, the development of biologically-targeted ultrasound contrast agents has expanded the role of ultrasound even further into molecular imaging applications.
View Article and Find Full Text PDFObjective: The diagnosis of acute coronary syndrome remains challenging especially in patients without clear symptoms or electrocardiographic and/or biomarker features. A hallmark of ischemia/reperfusion is activation of endothelial cells leading to altered expression of molecular markers, including selectins. In this context, we aimed to validate the value of ultrasound molecular imaging for detecting transient myocardial ischemia by using a clinically translatable dual P- and E-selectin-targeted ultrasound contrast agent (UCA) and microbubble (MB(selectin)).
View Article and Find Full Text PDFWith contrast-enhanced ultrasound (CEUS) now established as a valuable imaging modality for many applications, a more specific demand has recently emerged for quantifying perfusion and using measured parameters as objective indicators for various disease states. However, CEUS perfusion quantification remains challenging and is not well integrated in daily clinical practice. The development of VueBox™ alleviates existing limitations and enables quantification in a standardized way.
View Article and Find Full Text PDFThis work describes an in vivo study analyzing the effect of acoustic radiation force (ARF) on the binding of BR55 VEGFR2-specific contrast-agent microbubbles in a model of prostatic adenocarcinoma in rat. A commercial ultrasound system was modified by implementing high duty-cycle 3.5-MHz center frequency ARF bursts in a scanning configuration.
View Article and Find Full Text PDFPurpose: To evaluate whether parametric imaging with contrast material-enhanced ultrasonography (US) is superior to visual assessment for the differential diagnosis of focal liver lesions (FLLs).
Materials And Methods: This study had institutional review board approval, and verbal patient informed consent was obtained. Between August 2005 and October 2008, 146 FLLs in 145 patients (63 women, 82 men; mean age, 62.
Objective: : To evaluate BR38, a new microbubble-based blood pool agent for contrast-enhanced ultrasound imaging.
Materials And Methods: : The size characteristics of BR38 microbubbles were measured by Coulter counting. The backscatter and attenuation coefficients were determined as a function of frequency.
Ultrasound Med Biol
December 2010
The main goal of this study was to determine the optimal strategy for a real-time nonlinear contrast mode for small-animal imaging at high frequencies, on a new array-based micro-ultrasound system. Previously reported contrast imaging at frequencies above 15 MHz has primarily relied on subtraction schemes involving B-mode image data. These approaches provide insufficient contrast to tissue ratios under many imaging conditions.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
November 2010
The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2010
Subharmonic scattering of phospholipid-shell microbubbles excited at relatively low acoustic pressure amplitudes (<30 kPa) has been associated with echo responses from compression-only bubbles having initial surface tension values close to zero. In this work, the relation between sbharmonics and compression-only behavior of phospholipid-shell microbubbles was investigated, experimentally and by simulation, as a function of the initial surface tension by applying ambient overpressures of 0 and 180 mmHg. The microbubbles were excited using a 64-cycle transmit burst with a center frequency of 4 MHz and peak-negative pressure amplitudes ranging from 20 of 150 kPa.
View Article and Find Full Text PDFIndividual ultrasound contrast agent microbubbles (BR14) were characterized acoustically. The bubbles were excited at a frequency of 2 MHz and at peak-negative pressure amplitudes of 60 and 100 kPa. By measuring the transmit and receive transfer functions of both the transmit and receive transducers, echoes of individual bubbles were recorded quantitatively and compared to simulated data.
View Article and Find Full Text PDFMAT B III cells were insonified at ultrasound frequencies of 1.15 and 2.25 MHz in the presence of different ultrasound contrast agents (UCA) and a plasmid encoding for the green fluorescent protein.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
June 2006
A new formalism is presented for the destruction-replenishment perfusion quantification approach at low mechanical index. On the basis of physical considerations, best-fit methods should be applied using perfusion functions with S-shape characteristics. These functions are first described for the case of a geometry with a single flow velocity, then extended to the case of vascular beds with blood vessels having multiple flow velocity values and directions.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2005
In flow measurements in which microbubbles are involved, the amplitude and phase of the received echo signal are noticeably influenced by the transmitted ultrasound intensity. Previous studies have shown that, when such intensity is progressively increased, the Doppler spectrum is accordingly distorted, i.e.
View Article and Find Full Text PDFSmall (encapsulated) gas bubbles in a contrast medium react to an external oscillating pressure field with volume pulsations. Depending on the magnitude of the ultrasound wave, the vibrations will be related either linearly or nonlinearly to the applied acoustic pressure. For low acoustic pressures, the instantaneous radius oscillates linearly in relation to the amplitude of the applied external pressure field.
View Article and Find Full Text PDF