Introduction: The aim of the study is to assess the degree of adherence of medical laboratories to Kidney Disease Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease (CKD) in laboratory practice in Czechia and Slovakia.

Materials And Methods: An electronic questionnaire on adherence to KDIGO 2012 guideline was designed by an external quality assessment (EQA) provider SEKK spol. s.

View Article and Find Full Text PDF

The aim of this opinion is to summarize and to comment the consensus of the European Atherosclerosis Society and European Federation of Clinical Chemistry and Laboratory Medicine, which covers two main areas: 1) whether it is necessary / required to be fasting or non-fasting before blood sampling for lipids measurement, and what are the changes in the concentration of blood lipids during the day; 2) What decision limits (cut off value) of lipids and lipoproteins should be reported from laboratories and what is the recommended procedure for people with extreme / critical blood lipid values. Following parameters are discused: total cholesterol, LDL cholesterol, HDL cholesterol, non-HDL cholesterol, triglycerides, apolipoprotein A1, apolipoprotein B, lipoprotein(a). This opinion should be the object of interest both for professionals in clinical laboratories and for physicians in hospitals and out-patients departments.

View Article and Find Full Text PDF

Background: Quantification of monoclonal immunoglobulin free light chains (FLCs) in serum is used increasingly in clinical practice for the diagnosis, prognostic assessment, and treatment monitoring of monoclonal gammopathies. It is used as an adjunct to standard serum protein electrophoresis and immunofixation. However, methods for FLC quantification need further standardization and validation.

View Article and Find Full Text PDF

Background: We demonstrated that lyophilised EQA/PT control materials, under certain circumstances, provide equal information about bias values as pools of native patient sera, and that in some cases, long-term reliable work with such materials is possible.

Methods: Bias values, estimated from results of routine surveys of EQA SEKK (Czech Republic) programmes for eight basic blood serum analytes using lyophilised control materials, were compared with bias values reached in the CAP (USA) programme where pools of native and lyophilised patient sera were used.

Results: Results for the components Na, K, Mg, Cl, P, urea, glucose, and uric acid were assessed.

View Article and Find Full Text PDF

Background: The aim of our study was to identify the role of External Quality Assessment (EQA) programs in improving the quality of serum creatinine measurement and glomerular filtration rate (GFR) estimation. Comparison of results achieved during EQA with National Kidney Disease Education Program and College of American Pathologists guidelines identified an urgent need for an improvement in measurement quality. We compared actual results for serum creatinine measurement within the Czech Republic EQA with the requirements of EC Directive 98/79.

View Article and Find Full Text PDF

MUC1 mucins are tumour markers that are frequently indicated and examined, particularly as part of the treatment of breast cancer. Relatively large differences were observed in external quality assessment (EQA) between the results that were obtained by different immunoassay technologies. Thus, we compared eight routinely employed immunoassay sets for the determination of MUC1 mucins in the serum: six closed automated systems (AxSYM, Centaur, ECi Vitros, Elecsys 2010, Immulite 2000 and Kryptor), and two IRMA kits (ELSA CIS and IRMA-mat Byk-Sangtec).

View Article and Find Full Text PDF

The Czech External Quality Assessment Scheme organized a survey using 14 fresh-frozen sera targeted for cholesterol and glucose by reference measurement procedures. The objective was to investigate whether it could fulfil a post-market vigilance function for in vitro diagnostic medical devices and assess trueness of participants' results. It revealed a mean bias of +5.

View Article and Find Full Text PDF