Purpose: This study aimed to assess the magnitude and direction of dual-task interference in a listening effort dual-task paradigm in individuals with severe-to-profound hearing loss before and in the short- and long-term after cochlear implantation.

Design: The study sample consisted of 26 adult candidates for cochlear implantation with severe-to-profound hearing loss. The dual-task paradigm consisted of a primary speech understanding task, conducted in a quiet condition, and a favorable and unfavorable noise condition on the one hand and a secondary visual memory task on the other hand.

View Article and Find Full Text PDF

People with single-sided deafness (SSD) or asymmetric hearing loss (AHL) have particular difficulty understanding speech in noisy listening situations and in sound localization. The objective of this multicenter study is to evaluate the effect of a cochlear implant (CI) in adults with single-sided deafness (SSD) or asymmetric hearing loss (AHL), particularly regarding sound localization and speech intelligibility with additional interest in electric-acoustic pitch matching. A prospective longitudinal study at 7 European tertiary referral centers was conducted including 19 SSD and 16 AHL subjects undergoing cochlear implantation.

View Article and Find Full Text PDF

Purpose: The purpose of the current study was to assess dual-task interference (i.e., changes between the dual-task and baseline condition) in a listening effort dual-task paradigm in normal-hearing (NH) adults, hearing aid (HA) users, and cochlear implant (CI) users.

View Article and Find Full Text PDF

Objectives: Speech understanding is considered a bimodal and bidirectional process, whereby visual information (i.e., speechreading) and also cognitive functions (i.

View Article and Find Full Text PDF

This study aims to explore the effect of cochlear implantation on tinnitus perception. A prospective study was conducted on 72 adult hearing-impaired patients to evaluate tinnitus perception before and after cochlear implantation, using standardized tinnitus questionnaires (the tinnitus sample case-history questionnaire, tinnitus functional index (TFI), and tinnitus handicap inventory (THI)). A large variety of demographic and hearing- and implant-related data was collected from patient hospital records to explore possible associations with the implantation effect.

View Article and Find Full Text PDF

Individuals with single-sided deafness (SSD) have no access to binaural hearing, which limits their ability to localize sounds and understand speech in noisy environments. In addition, children with prelingual SSD are at risk for neurocognitive and academic difficulties. Early cochlear implantation may lead to improved hearing outcomes by restoring bilateral hearing.

View Article and Find Full Text PDF

Objectives: Given the close interconnection between the auditory and vestibular end organs, the increasingly broad application of (bilateral) cochlear implantation (CI) in children raises concern about its impact on the vestibular function. Unfortunately, literature on this matter is inconclusive and subject to several limitations. Therefore, this study aimed to elucidate the impact of pediatric CI on the vestibular function in a large sample of children, representative for the current CI population.

View Article and Find Full Text PDF

The aim of this study is to investigate short and long term residual hearing preservation (HP), corrected for the natural progress of hearing loss, in cochlear implant (CI) patients receiving a straight electrode array using a round window (RW) approach. A retrospective and cross-sectional analysis on patients who received a CI with a straight electrode using a RW approach ( = 60) was performed. Audiometric data were obtained at three time points, preoperatively, at first fitting, and one year or more postoperatively.

View Article and Find Full Text PDF

Introduction: In children with bilateral severe to profound hearing loss, bilateral hearing can be achieved by either bimodal stimulation (CIHA) or bilateral cochlear implantation (BICI). The aim of this study was to analyse the audiologic test protocol that is currently applied to make decisions regarding the bilateral hearing modality in the paediatric population.

Methods: Pre- and postoperative audiologic test results of 21 CIHA, 19 sequential BICI and 12 simultaneous BICI children were examined retrospectively.

View Article and Find Full Text PDF

Background: The 6p25 deletion syndrome is one of the many syndromes with both hearing impairment as well as vision impairment. However, the audiometric characteristics and radiological findings of patients with 6p25 deletions are only scarcely described in literature. This study focused on characterizing the audiometric and radiological features of a Belgian family with a chromosome 6p25 deletion.

View Article and Find Full Text PDF

Hearing loss in Stickler syndrome has received little attention due to the often more disabling ocular, orofacial and skeletal manifestations. Estimates suggest a global prevalence of sensorineural hearing loss (SNHL) ranging from 50 % to about 100 % though, depending on the underlying Stickler genotype. By performing extensive audiometric analysis in Stickler patients, we aimed to further elucidate the auditory phenotype.

View Article and Find Full Text PDF
Article Synopsis
  • Cochlear's Nucleus(®) 6 sound processor introduces advanced features like the SNR-NR noise reduction algorithm and SCAN environmental classifier, aiming to enhance user experience compared to the Nucleus(®) 5 system.
  • A clinical study involved 30 adult users, comparing speech recognition performance in noisy and quiet environments between the two devices, utilizing an ABBA design for accurate assessment.
  • Results showed a significant improvement in speech reception in noise with the Nucleus(®) 6 SCAN, while performance in quiet scenarios was similar between the two systems.
View Article and Find Full Text PDF

The objective of the current study was to evaluate the predictive role of the olivocochlear efferent reflex strength in temporary hearing deterioration in young adults exposed to music. This was based on the fact that a noise-protective role of the medial olivocochlear (MOC) system was observed in animals and that efferent suppression (ES) measured using contralateral acoustic stimulation (CAS) of otoacoustic emissions (OAEs) is capable of exploring the MOC system. Knowing an individual's susceptibility to cochlear damage after noise exposure would enhance preventive strategies for noise-induced hearing loss.

View Article and Find Full Text PDF

Objectives/hypothesis: Osteogenesis imperfecta (OI) is an autosomal-dominant connective-tissue disorder, predominantly characterized by bone fragility. Conductive hearing loss develops in half of the OI patients and often progresses to mixed loss. Findings of computed tomography (CT) and magnetic resonance (MR) imaging of the temporal bone in the largest series of OI patients to date are presented and correlated with the audiograms.

View Article and Find Full Text PDF

Intraoperative findings of stapes surgery in 34 ears from 22 patients with genetically confirmed osteogenesis imperfecta (OI) are reported, as well as the audiometric results after the longest postoperative follow-up published to date. Twenty-nine out of 34 ears underwent primary stapes surgery and 5 ears revision surgery. Postoperative audiometric follow-up ranged from 6 months to 37 years.

View Article and Find Full Text PDF

Objectives/hypothesis: Osteogenesis imperfecta (OI) is a heritable connective tissue disorder, predominantly characterized by bone fragility. In half of the patients, progressive hearing loss develops, which is associated with abnormal bony changes involving the middle ear ossicles and stapes footplate. In the present study, we investigated whether the development of hearing loss in OI may be related to the overall aberrant bone quality.

View Article and Find Full Text PDF

Background: Osteogenesis Imperfecta (OI) is a heritable connective tissue disorder mainly caused by mutations in the genes COL1A1 and COL1A2 and is associated with hearing loss in approximately half of the cases. The hearing impairment usually starts between the second and fourth decade of life as a conductive hearing loss, frequently evolving to mixed hearing loss thereafter. A minority of patients develop pure sensorineural hearing loss.

View Article and Find Full Text PDF

Objectives: To describe the audiologic phenotype in osteogenesis imperfecta (OI).

Study Design: Observational study.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

Objective: The aim of this study was to investigate the diagnostic capacity of three different rotatory tests, and to investigate the clinical effectiveness of the caloric, rotatory, and vestibular evoked myogenic potential (VEMP) test.

Design And Study Sample: Several rotatory tests--sinusoidal harmonic acceleration test (SHAT), pseudorandom rotation test (PRRT), velocity step test (VST)--and a caloric and a VEMP test, were given to 77 patients (mean age 52 years) with a unilateral peripheral vestibular pathology, and 80 control subjects (mean age 48 years).

Results: For the rotatory test, the highest diagnostic capacity was obtained with the 0.

View Article and Find Full Text PDF

The perceived negative influence of standard hearing protectors on communication is a common argument for not wearing them. Thus, "augmented" protectors have been developed to improve speech intelligibility. Nevertheless, their actual benefit remains a point of concern.

View Article and Find Full Text PDF

Objectives: To determine the output levels of a commercially available MPEG layer-3 (MP3) player and to evaluate changes in hearing after 1 hour of listening to the MP3 player.

Design: First, A-weighted sound pressure levels (measured in decibels [dBA]) for 1 hour of pop-rock music on an MP3 player were measured on a head and torso simulator. Second, after participants listened to 1 hour of pop-rock music using an MP3 player, changes in hearing were evaluated with pure-tone audiometry, transient-evoked otoacoustic emissions, and distortion product otoacoustic emissions.

View Article and Find Full Text PDF

Objective: The present study aimed at establishing clinically efficient stopping criteria for a multiple 80-Hz auditory steady-state response (ASSR) system.

Methods: In Experiment 1, data of 31 normal-hearing subjects were analyzed off-line to propose stopping rules. Consequently, ASSR recordings will be stopped when (1) all 8 responses reach significance and significance can be maintained for 8 consecutive sweeps; or (2) the mean noise levels were 4nV (if p-values were between 0.

View Article and Find Full Text PDF

Knowledge regarding the variability of transient-evoked otoacoustic emissions (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) is essential in clinical settings and improves their utility in monitoring hearing status over time. In the current study, TEOAEs and DPOAEs were measured with commercially available OAE-equipment in 56 normally-hearing ears during three sessions. Reliability was analysed for the retest measurement without probe-refitting, the immediate retest measurement with probe-refitting, and retest measurements after one hour and one week.

View Article and Find Full Text PDF

Objective: There is still controversy regarding the effects of aging on evoked otoacoustic emissions (EOAEs), as well as on the efferent system measured by contralateral acoustic stimulation of EOAEs. The purpose of this study was to investigate the deterioration in EOAEs and efferent suppression (ES) in a representative sample statistically controlling for the differences in hearing thresholds.

Methods: Seventy-one ears (20-79years) were included in the study, 47 of which had normal hearing thresholds, and 24 ears had a sensorineural high-frequency hearing loss caused by presbycusis.

View Article and Find Full Text PDF

Objectives: Age-related anatomical and morphologic vestibular deterioration has already been elaborated. Demonstrating a corresponding degradation in physiologic function, however, entails a much higher challenge. The objective of this study was to investigate age-related changes using rotational tests, caloric tests, and the vestibular-evoked myogenic potentials (VEMP) test.