Publications by authors named "Fredrik Georgsson"

We demonstrate a technique to improve structural data obtained from Optical Projection Tomography (OPT) using Image Fusion (IF) and contrast normalization. This enables the visualization of molecular expression patterns in biological specimens with highly variable contrast values. In the approach, termed IF-OPT, different exposures are fused by assigning weighted contrasts to each.

View Article and Find Full Text PDF

By adapting OPT to include the capability of imaging in the near infrared (NIR) spectrum, we here illustrate the possibility to image larger bodies of pancreatic tissue, such as the rat pancreas, and to increase the number of channels (cell types) that may be studied in a single specimen. We further describe the implementation of a number of computational tools that provide: 1/ accurate positioning of a specimen's (in our case the pancreas) centre of mass (COM) at the axis of rotation (AR); 2/ improved algorithms for post-alignment tuning which prevents geometric distortions during the tomographic reconstruction and 3/ a protocol for intensity equalization to increase signal to noise ratios in OPT-based BCM determinations. In addition, we describe a sample holder that minimizes the risk for unintentional movements of the specimen during image acquisition.

View Article and Find Full Text PDF

Since it was first presented in 2002, optical projection tomography (OPT) has emerged as a powerful tool for the study of biomedical specimen on the mm to cm scale. In this paper, we present computational tools to further improve OPT image acquisition and tomographic reconstruction. More specifically, these methods provide: semi-automatic and precise positioning of a sample at the axis of rotation and a fast and robust algorithm for determination of postalignment values throughout the specimen as compared to existing methods.

View Article and Find Full Text PDF

A set of monolithic stationary phases representing a broad span of monomers and porogens have been characterized directly in their capillary chromatographic format by computational assessment of their pore structure from transmission electron micrographs obtained after in situ embedment of the monoliths in contrast resin, followed by dissolution of the fused-silica tubing, further encasement of the resin-embedded monolith, and microtomy. This technique has been compared to mercury intrusion, a more conventional technique for macroporosity estimation. Supplementing the embedding resin by lead methacrylate gave a negative staining, and the resulting micrographs showed a good contrast between the polymeric monoliths and the embedding resin that allowed studies on the pore formation and polymer development.

View Article and Find Full Text PDF