Publications by authors named "Frederik Ceyssens"

Cr-doped VO thin film shows a huge resistivity change with controlled epitaxial strain at room temperature as a result of a gradual Mott metal-insulator phase transition with strain. This novel piezoresistive transduction principle makes Cr-doped VO thin film an appealing piezoresistive material. To investigate the piezoresistivity of Cr-doped VO thin film for implementation in MEMS sensor applications, the resistance change of differently orientated Cr-doped VO thin film piezoresistors with external strain change was measured.

View Article and Find Full Text PDF

Current single-cell technologies require large and expensive equipment, limiting their use to specialized labs. In this paper, we present for the first time a microfluidic device which demonstrates a combined method for full-electric cell capturing, analyzing, and selectively releasing with single-cell resolution. All functionalities are experimentally demonstrated on .

View Article and Find Full Text PDF

Basic, translational and clinical neuroscience are increasingly focusing on large-scale invasive recordings of neuronal activity. However, in large animals such as nonhuman primates and humans-in which the larger brain size with sulci and gyri imposes additional challenges compared to rodents, there is a huge unmet need to record from hundreds of neurons simultaneously anywhere in the brain for long periods of time. Here, we tested the electrical and mechanical properties of thin, flexible multi-electrode arrays (MEAs) inserted into the primary visual cortex of two macaque monkeys, and assessed their magnetic resonance imaging (MRI) compatibility and their capacity to record extracellular activity over a period of 1 year.

View Article and Find Full Text PDF

Elastic pneumatic actuators are fueling new devices and applications in soft robotics. Actuator miniaturization is critical to enable soft microsystems for applications in microfluidics and micromanipulation. This work proposes a fabrication technique to make out-of-plane bending microactuators entirely by soft lithography.

View Article and Find Full Text PDF

The presence of microorganisms performing extracellular electron transfer has been established in many environments. Research to determine their role is moving slowly due to the high cost of potentiostats and the variance of data with small number of replicates. Here, we present a 128-channel potentiostat, connected to a 128 gold electrode array.

View Article and Find Full Text PDF

The elucidation of cell-surface interactions and the development of model platforms to help uncover their underlying mechanisms remains vital to the design of effective biomaterials. To this end, dextran palmitates with varying degrees of substitution were synthesised with a multipurpose functionality: an ability to modulate surface energy through surface chemistry, and an ideal thermal behaviour for patterning. Herein, dextran palmitate films are produced by spin coating, and patterned by thermal nanoimprint lithography with nano-to-microscale topographies.

View Article and Find Full Text PDF
Article Synopsis
  • Melanoma cells can change between two states: a melanocytic state (pigment-producing) and a mesenchymal-like state (more mobile), and there may be intermediate states between them.
  • Researchers studied multiple melanoma culture samples using advanced RNA sequencing techniques to identify gene regulatory networks (GRNs) that explain these states and found a shared regulatory system for both extreme and intermediate states.
  • The study revealed that an intermediate state has its own specific genetic controls and migratory behavior, confirmed by experiments, and showed that this state is not just a mix of cell types but has a stable and unique regulatory pattern.
View Article and Find Full Text PDF

The detection and analysis of circulating tumor cells (CTCs) plays a crucial role in clinical practice. However, the heterogeneity and rarity of CTCs make their capture and separation from peripheral blood very difficult while maintaining their structural integrity and viability. We previously demonstrated the effectiveness of the Magnetic Cell Centrifuge Platform (MCCP), which combined the magnetic-labeling cell separation mechanism with the size-based method.

View Article and Find Full Text PDF

Objective: Long-term electrophysiological recordings of neural activity in freely behaving animals are indispensable to advance the understanding of complex brain function. It is a technical challenge to chronically monitor the detailed activity across multiple distributed brain regions in freely behaving animals over a period of months. Here we present a new implant for inserting multiple flexible polyimide probes into freely behaving rats for monitoring the brain activity over a long time period.

View Article and Find Full Text PDF

In the quest for chronically reliable and bio-tolerable brain interfaces there has been a steady evolution towards the use of highly flexible, polymer-based electrode arrays. The reduced mechanical mismatch between implant and brain tissue has shown to reduce the evoked immune response, which in turn has a positive effect on signal stability and noise. Unfortunately, the low stiffness of the implants also has practical repercussions, making surgical insertion extremely difficult.

View Article and Find Full Text PDF

Objective: This study describes the design and microfabrication of a foldable thin-film neural implant and investigates its suitability for electrical recording of deep-lying brain cavity walls.

Approach: A new type of foldable neural electrode array is presented, which can be inserted through a cannula. The microfabricated electrode is specifically designed for electrical recording of the cavity wall of thalamic lesions resulting from stroke.

View Article and Find Full Text PDF

This article presents an innovative high spectral resolution waveguide spectrometer, from the concept to the prototype demonstration and the test results. The main goal is to build the smallest possible Fourier transform spectrometer (FTS) with state of the art technology. This waveguide FTS takes advantage of a customized pattern of nano-samplers fabricated on the surface of a planar waveguide that allows the increase of the measurement points necessary for increasing the spectral bandwidth of the FTS in a fully static way.

View Article and Find Full Text PDF

A robust and low cost ionic liquid based strain sensor is fabricated for high strain measurements in biomedical applications (up to 40 % and higher). A tubular 5 mm long silicone microchannel with an inner diameter of 310 µm and an outer diameter of 650 µm is filled with an ionic liquid. Three ionic liquids have been investigated: 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide, ethylammonium nitrate and cholinium ethanoate.

View Article and Find Full Text PDF

Objective: This study investigates the suitability of a thin sheet of extracellular matrix (ECM) proteins as a resorbable coating for temporarily reinforcing fragile or ultra-low stiffness thin-film neural implants to be placed on the brain, i.e. microelectrocorticographic (µECOG) implants.

View Article and Find Full Text PDF

Objective: This work deals with studying and improving the insulation lifetime of polyimide-insulated thin film neural implants, or related polyimide-based medical implants.

Approach: The evolution of the leak impedance of insulated conductors was investigated in saline water at 40 °C. The fabrication process as commonly found in literature for polyimide/platinum/polyimide microelectrode arrays was compared with three possible improvements: one based on lowering the curing temperature of the lower layer, one based on chemical activation and one based on an additional plasma activation step.

View Article and Find Full Text PDF

Digital microfluidics is introduced as a novel platform with unique advantages for performing single-molecule detection. We demonstrate how superparamagnetic beads, used for capturing single protein molecules, can be printed with unprecedentedly high loading efficiency and single bead resolution on an electrowetting-on-dielectric-based digital microfluidic chip by micropatterning the Teflon-AF surface of the device. By transporting droplets containing suspended superparamagnetic beads over a hydrophilic-in-hydrophobic micropatterned Teflon-AF surface, single beads are trapped inside the hydrophilic microwells due to their selective wettability and tailored dimensions.

View Article and Find Full Text PDF

We have developed a novel type of neural electrode array for future brain-machine interfaces (BMI) and neural implants requiring high resolution recording and stimulation on the surface of brain lesions or on the cortex. The devices differ on two points from commonly used thin film electrode arrays: first, the thin film backbone of the implant is exceptionally thin (down to 5 microns) and finely patterned into spring-like structures. This increases the flexibility of the electrode array and allows stretching and conforming better to a quasi spherical cavity surface.

View Article and Find Full Text PDF

In this paper we report on the controlled biofunctionalization of the hydrophobic layer of electrowetting-on-dielectric (EWOD) based microfluidic chips with the aim to execute (adherent) cell-based assays. The biofunctionalization technique involves a dry lift-off method with an easy to remove Parylene-C mask and allows the creation of spatially controlled micropatches of biomolecules in the Teflon-AF(®) layer of the chip. Compared to conventional methods, this method (i) is fully biocompatible; and (ii) leaves the hydrophobicity of the chip surface unaffected by the fabrication process, which is a crucial feature for digital microfluidic chips.

View Article and Find Full Text PDF