Background: Although numerous suture-button fixation techniques for acromioclavicular (AC) joint reconstruction have been validated with biomechanical testing in the superior direction, clinical reports continue to demonstrate high rates of construct slippage and breakage.
Purpose: To compare the stability of a novel closed-loop double Endobutton construct with a commercially available cortical button system in both the axial and superior directions.
Study Design: Controlled laboratory study.
Background: Glenohumeral joint exposure during total shoulder arthroplasty (TSA) is obtained by releasing the subscapularis (SSC) with either an osteotomy or a tenotomy. Recently, concerns regarding SSC dysfunction after TSA have been raised. In order to avoid this complication, alternative surgical approaches that release the inferior 50% or 10% of the tendon have been described.
View Article and Find Full Text PDFObjectives: To compare lag-screw sliding characteristics and fixation stability of two cephalomedullary nails (CMN) with different lag-screw designs (solid and telescopic), we conducted a biomechanical study and an analysis of clinical results.
Methods: Six pairs of cadaver femurs with simulated intertrochanteric fractures were randomly assigned to one of two CMN fixations. Femur constructs were statically then cyclically loaded on an MTS machine.
Background: Because current instrumentation makes it possible to perform an arthroscopic transosseous rotator cuff repair, we performed a biomechanical comparison of a double-row transosseous equivalent rotator cuff repair using suture anchors to an arthroscopic, transosseous rotator cuff repair to determine if they provided similar fixation stability.
Methods: Six pairs of shoulders were used. One of each pair had a standard double row, transosseous equivalent arthroscopic rotator cuff repair using a suture-bridge technique with suture anchors, and the other had an arthroscopic transosseous repair using an Xbox technique.
J Long Term Eff Med Implants
August 2013
A polyethylene cup explanted after 41 years was examined using several analytical techniques to determine whether there was a material cause for the extremely low wear observed. Neither the amount of polyethylene oxidation nor crystallinity appeared to be a factor.
View Article and Find Full Text PDFBackground: Numerous reconstructive techniques for midfoot collapse secondary to Charcot neuroarthropathy have been described, but few have been studied biomechanically. The purpose of this study was to biomechanically compare 2 of the most common techniques.
Methods: Seven paired below-knee specimens were amputated through the talonavicular and calcaneocuboid joints.
Bull NYU Hosp Jt Dis
May 2013
The footprint is thought to be an important fact in rotator cuff repairs and has been used to compare various cuff fixation techniques. The following experiment used two different measurement sensors to evaluate the footprint as it is affected by suture tensions in a transosseous equivalent suture bridge repair. It was found that suture tension has a direct effect on footprint contact area and pressure and thus could affect healing and fixation stability and should be characterized in any study of comparative fixation techniques.
View Article and Find Full Text PDFObjectives: Because locked plates as a neutralization device for lag screw fracture fixation have different biomechanics than that of unlocked plates, we investigated how this would affect lag screw load at the fracture site. The purpose of this study was to assess the load at a fracture site compressed with a lag screw when both locked and unlocked plates are used as neutralization devices.
Materials And Methods: Nine cadaver femurs had a mid-shaft oblique fracture created and were fixed with a lag screw, incorporating load transducers at the fracture site and lag screw.
Pedicle screws (PS) can provide initial stabilization of anterior interbody femoral ring allograft (FRA) lumbar constructs. Translaminar screws (TLS) have also been advocated for this procedure. The objective of this study was to use an in vitro human cadaveric model to compare the stability of one-level anterior interbody lumbar constructs stabilized with PS and those stabilized with TLS.
View Article and Find Full Text PDFBull NYU Hosp Jt Dis
April 2012
A fracture construct, representing a worst-case model of a comminuted intertrochanteric fracture, was created in order to compare the fixation stability of two different cephalomedullary nails: one where the lag screw can telescope within itself to achieve displacement of the head-neck fragment, and the other where the solid lag screw slides only. After nail fixation, the models were loaded and then cycled, and positions of the head-neck fragment and lag screw were determined. Both nails similarly acted to limit motion of the head-neck fragment by the sliding of their lag screws, causing impingement of the fragment against the nail.
View Article and Find Full Text PDFAm J Orthop (Belle Mead NJ)
September 2011
The purpose of this study was to compare fixation stability and lag screw sliding characteristics between 2 different hip-nail lag screw designs, a telescoping screwbarrel and a solid helical blade. Simulated, unstable, 4-part intertrochanteric hip fractures were created in 6 pairs of cadaveric femurs. Each nail type was randomly assigned within each femur pair.
View Article and Find Full Text PDFDifferent acoustic frequencies have been used to diagnose progression of osteoarthritis, gross pathology, and wear in knee prostheses. It is possible that detailed analysis of higher frequencies could detect and quantify the smaller geometric changes (asperities) that develop in articular prosthetic wear. In this study we evaluated the feasibility of using ultrasonic emission to determine total knee arthroplasty (TKA) type and time from implantation using a simple, handheld measurement system.
View Article and Find Full Text PDFPurpose: We have occasionally observed suture loosening in initial suture legs after final fixation of adjacent suture legs in the lateral row of rotator cuff repairs during arthroscopic rotator cuff repair with transosseous-equivalent suture-bridge constructs. We sought to determine how this occurred and what effects it had on tendon fixation stability.
Methods: Six pairs of fresh-frozen human shoulders were prepared with a simulated cuff defect.
Bull NYU Hosp Jt Dis
April 2011
Background: Previous acoustic emission (AE) studies of the hip have proposed using AE for the diagnosis of musculoskeletal conditions and assessing the clinical status (loosening, wear, etc.) of prostheses. However, these investigations have had problems with spurious signal noises or complicated measurement techniques, or both.
View Article and Find Full Text PDFThere has been a steady increase in the number of revision total knee arthroplasties being performed in the United States. Hinge knee prostheses are used predominantly in complex primary or revision arthroplasties, often as salvage procedures. Significant improvement of the articulation between the rotating hinge mechanism and tibial component has decreased the stresses that contributed to earlier failures in previous generation designs.
View Article and Find Full Text PDFStudy Design: Anatomic study.
Objective: The purpose of this study is to determine the effect of the slip amount, slip angle, and disc height on the geometry of the L5 foramen in low-grade, low-dysplasia isthmic L5 spondylolisthesis using a human cadaveric model.
Summary Of Background Data: Radicular pain and varying degrees of nerve root dysfunction are present in many adult isthmic spondylolisthesis patients and can be the result of compression of the L5 root within its foramen.
Bull NYU Hosp Jt Dis
June 2010
This study compared the sliding characteristics of three lag screw designs used with trochanteric nails and determined the effects of lubrication on sliding. They were tested by an established method to measure initiation and ease of lag screw sliding. These tests were then repeated with calf serum lubrication.
View Article and Find Full Text PDFBackground: The addition of a lateral suture anchor fixation row to rotator cuff repairs has been shown to improve initial cuff reattachment strength and footprint area. This study evaluated the mechanical function of this lateral row by measuring suture tensions at the individual anchor sites.
Materials And Methods: Eight cadaveric shoulders underwent simulated rotator cuff repairs, using either double row or suture-bridge repair techniques.
Previous studies have suggested that femoral component positioning in resurfacing arthroplasty may affect strains in the femoral neck that could lead to decreased implant longevity. A strain gaged, Sawbones model was used to determine the femoral neck strains for a variety of resurfacing head translations and angulations. We found that head positions affected strain distributions, most positions leading to increased neck strains, often over 100%, with the exception being a varus head position where the superior neck strains decreased over 50%.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2010
Hypothesis: Our initial hypothesis was that the medial row of double-row rotator cuff repair techniques would bear most of the load on the repaired cuff.
Materials And Methods: Six cadaver shoulders underwent simulated rotator cuff repairs using sequential single row, double-row, and suture-bridge repair techniques. Suture tensions at each anchor were measured for several static, simulated shoulder positions by specially designed, instrumented anchors.
Purpose: To evaluate what effect the angle of screw-in suture anchor insertion has on fixation stability at the suture-tendon interface.
Methods: Supraspinatus tendons from 7 matched pairs of human cadaveric shoulders were split, yielding 4 tendons per cadaver. An experimental rotator cuff tear was created and repaired, using a 5.
The strengths of 3 hip spacer constructs--Steinmann pins, a short intramedullary nail (both cement-incorporated), and a Charnley prosthesis--were determined and compared with the strength of a commercially available hip spacer. The hip prosthesis construct was more than twice as strong as the other 2 constructs and was equivalent in strength to the commercial spacer. For spacer applications in which limited weight-bearing is anticipated, the hip prosthesis construct appears more efficacious, but its pros and cons should be compared with those of the commercial product.
View Article and Find Full Text PDFLocked plate technology has evolved in an effort to overcome the limitations associated with conventional plating methods, primarily for improving fixation in osteopenic bone. The development of screw torque and plate-bone interface friction is unnecessary with locked plate designs, significantly decreasing the amount of soft tissue dissection required for implantation, preserving the periosteal blood supply, and facilitating the use of minimally invasive percutaneous bridging fixation techniques. The locked plate is a fixed-angle device because angular motion does not occur at the plate screw interface.
View Article and Find Full Text PDFBackground: The Taylor spatial frame (TSF) is a second-generation circular fixator used for limb lengthening and deformity correction. While treating a patient for pseudoarthosis, gross instability of a particular TSF construct was observed. A subsequent mechanical study of the TSF was then performed to better understand how its configurations affect frame stability.
View Article and Find Full Text PDFPurpose: To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures.
Methods: A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX), A.