Intensity modulation treatments are widely used in radiotherapy because of many known advantages. In this context, the picket fence test (PF) is a relevant test to check the Multileaf Collimator (MLC) performances. So this work compares and evaluates three analysis platforms for the PF used routinely by three different institutions.

View Article and Find Full Text PDF

Background: Increasing numbers of patients with cardiac implantable electronic devices (CIEDs) are undergoing radiotherapy (RT) for cancer. The aim of the study was to prospectively evaluate the incidence, characteristics, and associated factors of CIED dysfunctions related to RT.

Methods: Between April 2013 and March 2020, all patients with a CIED who underwent ≥1 RT session were enrolled.

View Article and Find Full Text PDF

Introduction: Prostate requires a daily correction of its 3-dimensional position in relation with rectal distension. In this study, we sought to determine whether rectal distension with respect to the rectal behavior might have an impact on prostate translations and/or rotations during prostate image guided radiation therapy using a 6 degrees-of-freedom (DOF) couch.

Methods And Materials: We reviewed the data from 39 patients with localized prostate cancer treated with protracted external radiation therapy using a 6 DOF couch.

View Article and Find Full Text PDF

Background: To determine whether dose/volume specific endpoints (DVSE) or Area under the rectal DVH curve (rAUC) better predict acute gastrointestinal (GI) toxicity in prostate cancer patients treated with IMRT in the era of daily image guidance (IG-IMRT).

Methods: A set of DVSE was recorded from V25 to V75 (increments of 5Gy) (both in % and in cc) for 180 men. The rAUC was calculated for doses ranging between 25Gy and 50Gy (rAUC).

View Article and Find Full Text PDF

Purpose: Salvage prostate permanent implant (sPPI) for postradiation local failure provides high rates of biochemical control. The cumulative dose delivered to the prostate and the rectum is still unknown.

Methods And Materials: We reviewed the postimplant CT-based dosimetry of 18 selected patients who underwent sPPI with (125)I seeds for isolated biopsy-proven local failure several years after external beam radiation therapy.

View Article and Find Full Text PDF

Purpose: To determine whether post-implant MRI-based dosimetry of the Dominant Intra-prostatic Lesion (DIL) could best predict the occurrence of PSA bounce after prostate brachytherapy.

Methods And Materials: We selected 66 patients with a low risk prostate cancer treated with (125)I prostate brachytherapy as monotherapy. Post-implant dosimetry based on day 30 CT-scan and multiparametric MRI co-registration was generated: planned D90, D95, V100, V150 values were calculated for each DIL.

View Article and Find Full Text PDF

Background And Purpose: We aimed to evaluate the patterns of loco-regional failure (LRF) after exclusive chemoradiotherapy (eCRT) for esophageal cancer with respect to planned dose and/or the incidental (unplanned) dose outside target volumes.

Materials And Methods: Co-image registration of CT or (18)F-FDG PET-CT at the time of failure (tf) and at the time of CRT (t0) was performed in 34 patients with LRF. Dosimetric parameters with regard to local failure (LF), nodal failure (NF) and involved nodal stations (NS) were derived.

View Article and Find Full Text PDF