J Cardiovasc Electrophysiol
July 2020
His bundle pacing (HBP) offers physiologic pacing by placing the pacing lead directly to the His bundle. We present a case in which a HBP lead, implanted at the fragile membranous septum, resulted in a persistent restrictive perimembranous ventricular septal defect (VSD). This complication of HBP has not been reported before but brings new insights in the discussion regarding the optimal position of a pacing lead in the ventricular septum.
View Article and Find Full Text PDFBackground: There are anecdotal reports of sudden death despite a functional implantable cardioverter defibrillator (ICD). We sought to describe scenarios leading to fatal or near-fatal outcome due to inappropriately inhibited ICD therapy in devices programmed with single-chamber detection criteria.
Methods: Programmed settings, episode lists, and intracardiac electrograms from 24 patients with a life-threatening event (n = 12) or fatal outcome (n = 12) related to failed ventricular arrhythmia detection were used to clarify the underlying scenario.
An isoproterenol infusion was administered during an electrophysiologic study (EPS) in a patient with a history of near syncope, left bundle branch block, and no documented atrioventricular (AV) block. Isoproterenol precipitated classic 2:1 Infra-Hisian AV block most probably proximal to the site of recording a His-Purkinje potential consistent with right bundle branch activity. Paroxysmal AV block also occurred during isoproterenol washout at a different site located distal to the presumed right bundle branch potential.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
January 2013
Alternans of the ventricular electrogram (VEGM) during ventricular tachycardia (VT) is a rare cause of ventricular undersensing by an implantable cardioverter-defibrillator (ICD). This report describes a patient with a St. Jude ICD who exhibited sustained monomorphic VT associated with surface QRS alternans, alternating cycle lengths, alternans of the VEGM causing intermittent undersensing of the smaller component, and intermittent 2:1 counting of ventricular intervals during 1:1 sensing in response to the ICD detection algorithm.
View Article and Find Full Text PDFSensing of left ventricular (LV) activity in some devices used for cardiac resynchronization therapy (CRT) was designed primarily to prevent the delivery of an LV stimulus into the LV vulnerable period. Such a sensing function of the LV channel is not universally available in contemporary CRT devices. Recordings of LV electrograms may provide special diagnostic data unavailable solely from the standard right ventricular electrogram and corresponding marker channel.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2013
Pacing Clin Electrophysiol
January 2013
Background: Remote monitoring allows for interrogation and extensive data retrieval of implantable cardioverter-defibrillators (ICDs). Data on ICD parameters at the time of death and afterwards are limited. The purpose of this retrospective study was to examine the changes in lead impedances of ICDs at the time of death and afterwards.
View Article and Find Full Text PDF