Background: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds.
Objective: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences.
Background: Left pulmonary artery (LPA) stenting is often required in single ventricle (SV) patients. Due to their close anatomical relationship an LPA stent could potentially compress the left main bronchus (LMB). We assessed the impact of LPA stenting on bronchial size, pulmonary volumes, and lung function in a cohort of SV patients.
View Article and Find Full Text PDFPurpose: Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC).
Material And Methods: 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.
Introduction: The aim of this study was to evaluate the feasibility of identifying the fetal cardiac and thoracic vascular structures with non-gated dynamic balanced steady-state free precession (SSFP) MRI sequences.
Methods: We retrospectively assessed the visibility of cardiovascular anatomy in 60 fetuses without suspicion of congenital heart defect. Non-gated dynamic balanced SSFP sequences were acquired in three anatomic planes of the fetal thorax.
Purpose: To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR.
Methods: In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA.
Background: Children with orofacial deformity may require repeated imaging of the facial skeleton.
Objective: To test the feasibility and accuracy of "black bone" magnetic resonance imaging (MRI) for assessing facial deformity in children.
Materials And Methods: Three-dimensional (3-D) black bone gradient echo sequences (flip angle 5°, submillimetre spatial resolution) from 10 children (median age: 13 years, range: 2-16 years), who underwent MRI of the temporomandibular joints, were evaluated with multiplanar reconstruction and 3-D rendering tools.
Objectives: To use 4D-flow MRI to describe systemic and non-systemic ventricular flow organisation and energy loss in patients with repaired d-transposition of the great arteries (d-TGA) and normal subjects.
Methods: Pathline tracking of ventricular volumes was performed using 4D-flow MRI data from a 1.5-T GE Discovery MR450 scanner.
Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15-20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT.
View Article and Find Full Text PDFPurpose: To analyze the dependence of flow volume measurements on 3D cine phase-contrast MRI (4D-flow MRI) background phase correction.
Methods: In 31 subjects scanned on a 1.5T MRI scanner, flow volume measurements at 4 vessels were made using phantom corrected 2D phase contrast and 4D flow with background phase correction performed by linear, second, third, and fourth-order polynomial fitting to static tissue.
The hippocampus is a key component of emotional and memory circuits and is broadly connected throughout the brain. We tracked the whole-brain connections of white matter fibres from the hippocampus using ultra-high angular resolution diffusion MRI in both a single 1150-direction dataset and a large normal cohort (n = 94; 391-directions). Using a connectomic approach, we identified six dominant pathways in terms of strength, length and anatomy, and characterised them by their age and gender variation.
View Article and Find Full Text PDFPeripheral veno-arterial extra corporeal membrane oxygenation (VA-ECMO) is an established technique for short-to-medium support of patients with severe cardiac failure. However, in patients with concomitant respiratory failure, the residual native circulation will provide deoxygenated blood to the upper body, and may cause differential hypoxemia of the heart and brain. In this paper, we present a general computational framework for the identification of differential hypoxemia risk in VA-ECMO patients.
View Article and Find Full Text PDFBackground: Abnormal flow dynamics play an early and causative role in pathologic changes of the ascending aorta.
Purpose: To identify: 1) the changes in flow, shape, and size that occur in the ascending aorta with normal human ageing and 2) the influence of these factors on aortic flow dynamics.
Study Type: Retrospective.
Am J Physiol Heart Circ Physiol
November 2018
Wall shear stress (WSS) plays a governing role in vascular remodeling and a pathogenic role in vessel wall diseases. However, little is known of the normal WSS patterns in the aorta as there is currently no practical means to routinely measure WSS and no normal ranges derived from population data exist. WSS measurements were made on the aorta of 224 subjects with normal anatomy using four-dimensional flow MRI with multiple encoding velocities and an optimized postprocessing routine.
View Article and Find Full Text PDFBackground: Chronic descending thoracic aortic dissection (CDTAD) following surgical repair of ascending aortic dissection requires long-term imaging surveillance. We investigated four-dimensional (4D)-flow magnetic resonance imaging (MRI) with a novel multi-velocity encoding (multi-VENC) technique as an emerging clinical method enabling the dynamic quantification of blood volume and velocity throughout the cardiac cycle.
Methods: Patients with CDTAD (n = 10; mean age, 55.
Background: Femoroacetabular impingement syndrome (FAI), a hip disorder affecting active young adults, is believed to be a leading cause of hip osteoarthritis (OA). Current management approaches for FAI include arthroscopic hip surgery and physiotherapy-led non-surgical care; however, there is a paucity of clinical trial evidence comparing these approaches. In particular, it is unknown whether these management approaches modify the future risk of developing hip OA.
View Article and Find Full Text PDFAsian Cardiovasc Thorac Ann
January 2018
Imaging-based evaluation of cardiac structure and function remains paramount in the diagnosis and monitoring of congenital heart disease in childhood. Accurate measurements of intra- and extracardiac hemodynamics are required to inform decision making, allowing planned timing of interventions prior to deterioration of cardiac function. Four-dimensional flow magnetic resonance imaging is a nonionizing noninvasive technology that allows accurate and reproducible delineation of blood flow at any anatomical location within the imaging volume of interest, and also permits derivation of physiological parameters such as kinetic energy and wall shear stress.
View Article and Find Full Text PDFBackground: Diastolic dysfunction is a major cause of morbidity in obese individuals. We aimed to assess the ability of magnetic resonance imaging (MRI) derived left atrial (LA) strain to detect early diastolic dysfunction in individuals with obesity and type 2 diabetes, and to explore the association between cardiac adipose tissue and LA function.
Methods: Twenty patients with obesity and T2D (55 ± 8 years) and nineteen healthy controls (48 ± 13 years) were imaged using cine steady state free precession and 2-point Dixon cardiovascular magnetic resonance.
Purpose: 4D-flow MRI obtains a time-dependent 3D velocity field; however, its use for the calculation of higher-order parameters is limited by noise. We present an algorithm for denoising 4D-flow data.
Theory And Methods: By integrating a velocity field and eliminating streamlines in noisy flow, depicted by high curvature, a denoised dataset may be extracted.
Purpose: To quantitatively characterize the central role of vortex formation on the flow patterns and energy transfer within the right atrium (RA).
Materials And Methods: 4D-flow magnetic resonance imaging (MRI) data with multiple encoding velocities was acquired in 12 healthy subjects at 3T. Particles entering the RA were classified according to the origin of entry.
Purpose: To show that the use of a multi-velocity encoding (VENC) 4D-flow approach offers significant improvements in the characterization of complex flow in the aorta. Four-dimensional flow magnetic resonance imaging (MRI) (4D-flow) can be used to measure complex flow patterns and dynamics in the heart and major vessels. The quality of the information derived from these measures is dependent on the accuracy of the vector field, which is limited by the vector-to-noise ratio.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
April 2011
Spontaneous internal carotid artery (ICA) dissection (sICAD) results from an intimal tear located around the distal carotid sinus. The mechanisms causing the tear are unknown. This case-control study tested the hypotheses that head movements increase the wall stress in the cervical ICA and that the stress increase is greater in patients with sICAD than in controls.
View Article and Find Full Text PDF