Objective: Ultra long-term monitoring with subcutaneous EEG (sqEEG) offers objective outpatient recording of electrographic seizures as an alternative to self-reported epileptic seizure diaries. This methodology requires an algorithm-based automatic seizure detection to indicate periods of potential seizure activity to reduce the time spent on visual review. The objective of this study was to evaluate the performance of a sqEEG-based automatic seizure detection algorithm.
View Article and Find Full Text PDFComputational sleep scoring from multimodal neurophysiological time-series (polysomnography PSG) has achieved impressive clinical success. Models that use only a single electroencephalographic (EEG) channel from PSG have not yet received the same clinical recognition, since they lack Rapid Eye Movement (REM) scoring quality. The question whether this lack can be remedied at all remains an important one.
View Article and Find Full Text PDFUltra-long-term electroencephalographic (EEG) registration using minimally invasive low-channel devices is an emerging technology to assess sporadic seizure events. Highly sensitive automatic seizure detection algorithms are needed for semiautomatic evaluation of these prolonged recordings. We describe the design and validation of a deep neural network for two-channel seizure detection.
View Article and Find Full Text PDFObjective: To evaluate the diagnostic performance of artificial intelligence (AI)-based algorithms for identifying the presence of interictal epileptiform discharges (IEDs) in routine (20-min) electroencephalography (EEG) recordings.
Methods: We evaluated two approaches: a fully automated one and a hybrid approach, where three human raters applied an operational IED definition to assess the automated detections grouped into clusters by the algorithms. We used three previously developed AI algorithms: Encevis, SpikeNet, and Persyst.
Objective: To quantify effects of sleep and seizures on the rate of interictal epileptiform discharges (IED) and to classify patients with epilepsy based on IED activation patterns.
Methods: We analyzed long-term EEGs from 76 patients with at least one recorded epileptic seizure during monitoring. IEDs were detected with an AI-based algorithm and validated by visual inspection.
A standard format for neurophysiology data is urgently needed to improve clinical care and promote research data exchange. Previous neurophysiology format standardization projects have provided valuable insights into how to accomplish the project. In medical imaging, the Digital Imaging and Communication in Medicine (DICOM) standard is widely adopted.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2020
EEG monitoring of early brain function and development in neonatal intensive care units may help to identify infants with high risk of serious neurological impairment and to assess brain maturation for evaluation of neurodevelopmental progress. Automated analysis of EEG data makes continuous evaluation of brain activity fast and accessible. A convolutional neural network (CNN) for regression of EEG maturational age of premature neonates from marginally preprocessed serial EEG recordings is proposed.
View Article and Find Full Text PDFObjective: To validate an artificial intelligence-based computer algorithm for detection of epileptiform EEG discharges (EDs) and subsequent identification of patients with epilepsy.
Methods: We developed an algorithm for automatic detection of EDs, based on a novel deep learning method that requires a low amount of labeled EEG data for training. Detected EDs are automatically grouped into clusters, consisting of the same type of EDs, for rapid visual inspection.
Background: Critical care continuous electroencephalography (CCEEG) represents the gold standard for detection of nonconvulsive status epilepticus (NCSE) in neurological critical care patients. It is unclear which findings on short-term routine EEG and which clinical parameters predict NCSE during subsequent CCEEG reliably. The aim of the present study was to assess the prognostic significance of changes within the first 30 min of EEG as well as of clinical parameters for the occurrence of NCSE during subsequent CCEEG.
View Article and Find Full Text PDFOngoing or recurrent seizure activity without prominent motor features is a common burden in neurological critical care patients and people with epilepsy during ICU stays. Continuous EEG (CEEG) is the gold standard for detecting ongoing ictal EEG patterns and monitoring functional brain activity. However CEEG review is very demanding and time consuming.
View Article and Find Full Text PDFObjective: To develop a computational method to detect and quantify burst suppression patterns (BSP) in the EEGs of critical care patients. A multi-center validation study was performed to assess the detection performance of the method.
Methods: The fully automatic method scans the EEG for discontinuous patterns and shows detected BSP and quantitative information on a trending display in real-time.
Objectives: To study periodic and rhythmic EEG patterns classified according to Standardized Critical Care EEG Terminology (SCCET) of the American Clinical Neurophysiology Society and their relationship to electrographic seizures.
Methods: We classified 655 routine EEGs in 371 consecutive critically ill neurological patients into (1) normal EEGs or EEGs with non-specific abnormalities or interictal epileptiform discharges, (2) EEGs containing unequivocal ictal EEG patterns, and (3) EEGs showing rhythmic and periodic EEG patterns of 'ictal-interictal uncertainty' (RPPIIIU) according to SCCET.
Results: 313 patients (84.
Annu Int Conf IEEE Eng Med Biol Soc
August 2015
Automatic EEG-processing systems such as seizure detection systems are more and more in use to cope with the large amount of data that arises from long-term EEG-monitorings. Since artifacts occur very often during the recordings and disturb the EEG-processing, it is crucial for these systems to have a good automatic artifact detection. We present a novel, computationally inexpensive automatic artifact detection system that uses the spatial distribution of the EEG-signal and the location of the electrodes to detect artifacts on electrodes.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
June 2012
An online seizure detection algorithm for long-term EEG monitoring is presented, which is based on a periodic waveform analysis detecting rhythmic EEG patterns and an adaptation module automatically adjusting the algorithm to patient-specific EEG properties. The algorithm was evaluated using 4.300 hours of unselected EEG recordings from 48 patients with temporal lobe epilepsy.
View Article and Find Full Text PDF