Publications by authors named "Frantisek Duris"

With the rapid growth of massively parallel sequencing technologies, still more laboratories are utilising sequenced DNA fragments for genomic analyses. Interpretation of sequencing data is, however, strongly dependent on bioinformatics processing, which is often too demanding for clinicians and researchers without a computational background. Another problem represents the reproducibility of computational analyses across separated computational centres with inconsistent versions of installed libraries and bioinformatics tools.

View Article and Find Full Text PDF

Copy number variants (CNVs) are an important type of human genome variation, which play a significant role in evolution contribute to population diversity and human genetic diseases. In recent years, next generation sequencing has become a valuable tool for clinical diagnostics and to provide sensitive and accurate approaches for detecting CNVs. In our previous work, we described a non-invasive prenatal test (NIPT) based on low-coverage massively parallel whole-genome sequencing of total plasma DNA for detection of CNV aberrations ≥600 kbp.

View Article and Find Full Text PDF

The reliability of non-invasive prenatal testing is highly dependent on accurate estimation of fetal fraction. Several methods have been proposed up to date, utilizing different attributes of analyzed genomic material, for example length and genomic location of sequenced DNA fragments. These two sources of information are relatively unrelated, but so far, there have been no published attempts to combine them to get an improved predictor.

View Article and Find Full Text PDF

Recent advances in massively parallel shotgun sequencing opened up new options for affordable non-invasive prenatal testing (NIPT) for fetus aneuploidy from DNA material extracted from maternal plasma. Tests typically compare chromosomal distributions of a tested sample with a control set of healthy samples with unaffected fetuses. Deviations above certain threshold levels are concluded as positive findings.

View Article and Find Full Text PDF

Low-coverage massively parallel genome sequencing for non-invasive prenatal testing (NIPT) of common aneuploidies is one of the most rapidly adopted and relatively low-cost DNA tests. Since aggregation of reads from a large number of samples allows overcoming the problems of extremely low coverage of individual samples, we describe the possible re-use of the data generated during NIPT testing for genome scale population specific frequency determination of small DNA variants, requiring no additional costs except of those for the NIPT test itself. We applied our method to a data set comprising of 1501 original NIPT test results and evaluated the findings on different levels, from in silico population frequency comparisons up to wet lab validation analyses using a gold-standard method based on Sanger sequencing.

View Article and Find Full Text PDF

Although massively parallel sequencing (MPS) is becoming common practice in both research and routine clinical care, confirmation requirements of identified DNA variants using alternative methods are still topics of debate. When evaluating variants directly from MPS data, different read depth statistics, together with specialized genotype quality scores are, therefore, of high relevance. Here we report results of our validation study performed in two different ways: 1) confirmation of MPS identified variants using Sanger sequencing; and 2) simultaneous Sanger and MPS analysis of exons of selected genes.

View Article and Find Full Text PDF

Motivation: Non-invasive prenatal testing or NIPT is currently among the top researched topic in obstetric care. While the performance of the current state-of-the-art NIPT solutions achieve high sensitivity and specificity, they still struggle with a considerable number of samples that cannot be concluded with certainty. Such uninformative results are often subject to repeated blood sampling and re-analysis, usually after two weeks, and this period may cause a stress to the future mothers as well as increase the overall cost of the test.

View Article and Find Full Text PDF

Motivation: Short tandem repeats (STRs) are stretches of repetitive DNA in which short sequences, typically made of 2-6 nucleotides, are repeated several times. Since STRs have many important biological roles and also belong to the most polymorphic parts of the human genome, they became utilized in several molecular-genetic applications. Precise genotyping of STR alleles, therefore, was of high relevance during the last decades.

View Article and Find Full Text PDF

Different protocols based on Illumina high-throughput DNA sequencing and denaturing gradient gel electrophoresis (DGGE)-cloning were developed and applied for investigating hot spring related samples. The study was focused on three target genes: archaeal and bacterial 16S rRNA and mcrA of methanogenic microflora. Shorter read lengths of the currently most popular technology of sequencing by Illumina do not allow analysis of the complete 16S rRNA region, or of longer gene fragments, as was the case of Sanger sequencing.

View Article and Find Full Text PDF

Objectives: The aims of this study were to test the utility of benchtop NGS platforms for NIPT for trisomy 21 using previously published z score calculation methods and to optimize the sample preparation and data analysis with use of in silico and physical size selection methods.

Methods: Samples from 130 pregnant women were analyzed by whole genome sequencing on benchtop NGS systems Ion Torrent PGM and MiSeq. The targeted yield of 3 million raw reads on each platform was used for z score calculation.

View Article and Find Full Text PDF