Fetal asphyxia, a condition resulting from the combined effects of hypoxia and hypercapnia, leads to approximately 900,000 annual deaths worldwide. One cause is umbilical cord compression during labor-induced uterine contractions, disrupting the transport of metabolites to and from the placenta, and resulting in asphyxia. Current fetal well-being assessment relies on monitoring fetal heart rate and uterine contractions as indicators of oxygen delivery to the brain.
View Article and Find Full Text PDFConventional static culture of organoids necessitates weekly manual passaging and results in nonhomogeneous exposure of organoids to nutrients, oxygen, and toxic metabolites. Here, we developed a miniaturized spinning bioreactor, RPMotion, specifically optimized for accelerated and cost-effective culture of epithelial organoids under homogeneous conditions. We established tissue-specific RPMotion settings and standard operating protocols for the expansion of human epithelial organoids derived from the liver, intestine, and pancreas.
View Article and Find Full Text PDFDoppler ultrasound is a commonly used method to assess hemodynamics of the fetal cardiovascular system and to monitor the well-being of the fetus. Indices based on the velocity profile are often used for diagnosis. However, precisely linking these indices to specific underlying physiology factors is challenging.
View Article and Find Full Text PDFHeart Failure (HF) is a life-threatening condition. It affects more than 64 million people worldwide. Early diagnosis of HF is extremely crucial.
View Article and Find Full Text PDFBackground: Personalized modeling is a promising tool to improve abdominal aortic aneurysm (AAA) rupture risk assessment. Computed tomography (CT) and quantitative flow (Q-flow) magnetic resonance imaging (MRI) are widely regarded as the gold standard for acquiring patient-specific geometry and velocity profiles, respectively. However, their frequent utilization is hindered by various drawbacks.
View Article and Find Full Text PDFFor more than 60 years, humans have travelled into space. Until now, the majority of astronauts have been professional, government agency astronauts selected, in part, for their superlative physical fitness and the absence of disease. Commercial spaceflight is now becoming accessible to members of the public, many of whom would previously have been excluded owing to unsatisfactory fitness or the presence of cardiorespiratory diseases.
View Article and Find Full Text PDFAssessing a patient's risk of scar-based ventricular tachycardia (VT) after myocardial infarction is a challenging task. It can take months to years after infarction for VT to occur. Also, if selected for ablation therapy, success rates are low.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
February 2024
In most variance-based sensitivity analysis (SA) approaches applied to biomechanical models, statistical independence of the model input is assumed. However, often the model inputs are correlated. This might alter the interpretation of the SA results, which may severely impact the guidance provided during model development and personalization.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
January 2024
In silico trials are a promising way to increase the efficiency of the development, and the time to market of cardiovascular implantable devices. The development of transcatheter aortic valve implantation (TAVI) devices, could benefit from in silico trials to overcome frequently occurring complications such as paravalvular leakage and conduction problems. To be able to perform in silico TAVI trials virtual cohorts of TAVI patients are required.
View Article and Find Full Text PDFThe past decade has seen a dramatic rise in consumer technologies able to monitor a variety of cardiovascular parameters. Such devices initially recorded markers of exercise, but now include physiological and health-care focused measurements. The public are keen to adopt these devices in the belief that they are useful to identify and monitor cardiovascular disease.
View Article and Find Full Text PDFIn this study, we propose a Convolutional Neural Network (CNN) with an assembly of non-linear fully connected layers for estimating body height and weight using a limited amount of data. This method can predict the parameters within acceptable clinical limits for most of the cases even when trained with limited data.
View Article and Find Full Text PDFObjectives: The ELANA® Heart Bypass creates a standardized sutureless anastomosis. Hereby, we investigate the influence of arteriotomy and graft size on coronary hemodynamics.
Methods: A computational fluid dynamics (CFD) model was developed.
Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated.
View Article and Find Full Text PDFTo improve abdominal aortic aneurysm (AAA) rupture risk assessment, a large, longitudinal study on AAA hemodynamics and biomechanics is necessary, using personalized fluid-structure interaction (FSI) modeling. 3-dimensional, time-resolved ultrasound (3D+t US) is the preferred image modality to obtain the patient-specific AAA geometry for such a study, since it is safe, affordable and provides temporal information. However, the 3D+t US field-of-view (FOV) is limited and therefore often fails to capture the inlet and aorto-iliac bifurcation geometry.
View Article and Find Full Text PDFRupture risk estimation of abdominal aortic aneurysm (AAA) patients is currently based on the maximum diameter of the AAA. Mechanical properties that characterize the mechanical state of the vessel may serve as a better rupture risk predictor. Non-electrocardiogram-gated (non-ECG-gated) freehand 2D ultrasound imaging is a fast approach from which a reconstructed volumetric image of the aorta can be obtained.
View Article and Find Full Text PDFMethods for patient-specific abdominal aortic aneurysm (AAA) progression monitoring and rupture risk assessment are widely investigated. Three-dimensional ultrasound can visualize the AAA's complex geometry and displacement fields. However, ultrasound has a limited field of view and low frame rate (i.
View Article and Find Full Text PDFComput Methods Programs Biomed
December 2022
Background And Objective: The left ventricular pressure waveform is indispensable for the construction of the pressure strain loop when investigating coronary artery disease (CAD) patients. In previous studies by others, exclusion of CAD patients has not allowed a reliable estimation of the left ventricular pressure waveform from the pressure strain loop of these patients. To remedy this, we propose a patient-specific noninvasive method for the estimation of left ventricular pressure.
View Article and Find Full Text PDFBackground: Preterm birth is the main cause of neonatal deaths with increasing mortality and morbidity rates with decreasing GA at time of birth. Currently, premature infants are treated in neonatal intensive care units to support further development. However, the organs of, especially, extremely premature infants (born before 28 weeks of GA) are not mature enough to function optimally outside the womb.
View Article and Find Full Text PDFSurvivors of myocardial infarction are at risk of life-threatening ventricular tachycardias (VTs) later in their lives. Current guidelines for implantable cardioverter defibrillators (ICDs) implantation to prevent VT-related sudden cardiac death is solely based on symptoms and left ventricular ejection fraction. Catheter ablation of scar-related VTs is performed following ICD therapy, reducing VTs, painful shocks, anxiety, depression and worsening heart failure.
View Article and Find Full Text PDFThe central aortic pressure (CAP) provides insights into the prediction, prevention, diagnosis, and treatment of cardiovascular disease, but can't be directly measured non-invasively. Therefore, the development of a noninvasive CAP estimation method based on the non-invasively measured peripheral pressure waveform is critical for clinical decisions based on the CAP. Some existing widely applied methods, such as the generalized transfer function (GTF) method relating measured peripheral pressure to the CAP, do not or only partly account for inter-subject or intra-subject variability of the cardiovascular system.
View Article and Find Full Text PDFLiquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design.
View Article and Find Full Text PDFObstruction of blood flow due to thrombosis is a major cause of ischemic stroke, myocardial infarction, and in severe cases, mortality. In particular, in blood wetting medical devices, thrombosis is a common reason for failure. The prediction of thrombosis by understanding signaling pathways using computational models, lead to identify the risk of thrombus formation in blood-contacting devices and design improvements.
View Article and Find Full Text PDFIn the above article [1], one error, (1), was found which has an impact on the results and interpretation of the image quality that was described in four sentences, (2)-(5). This correction does not mitigate the overall conclusion of this work, but does positively support improvements of the proposed method (multi-perspective ultrafast imaging) in comparison with the standard method (focused line-by-line imaging).
View Article and Find Full Text PDFSignificance: Intraplaque hemorrhage (IPH) is an important indicator of plaque vulnerability. Early detection could aid the prevention of stroke.
Aim: We aim to detect IPH with single wavelength PA imaging in vivo and to improve image quality.