Objective: Short-term outcomes of deep brain stimulation of the anterior nucleus of the thalamus (ANT-DBS) were reported for people with drug-resistant focal epilepsy (PwE). Because long-term data are still scarce, the Medtronic Registry for Epilepsy (MORE) evaluated clinical routine application of ANT-DBS.
Methods: In this multicenter registry, PwE with ANT-DBS were followed up for safety, efficacy, and battery longevity.
Background And Objectives: The efficacy of deep brain stimulation of the anterior nucleus of the thalamus (ANT DBS) in patients with drug-resistant epilepsy (DRE) was demonstrated in the double-blind Stimulation of the Anterior Nucleus of the Thalamus for Epilepsy randomized controlled trial. The Medtronic Registry for Epilepsy (MORE) aims to understand the safety and longer-term effectiveness of ANT DBS therapy in routine clinical practice.
Methods: MORE is an observational registry collecting prospective and retrospective clinical data.
Objective: Deep Brain Stimulation (DBS) in the Anterior Nucleus of the Thalamus (ANT) has been shown to be a safe and efficacious treatment option for patients with Drug-Resitant focal Epilepsy (DRE). The ANT has been selected frequently in open and controlled studies for bilateral DBS. There is a substantial variability in ANT-DBS outcomes which is not fully understood.
View Article and Find Full Text PDFDeep brain stimulation (DBS) has been proposed for severe, chronic, treatment-refractory obsessive-compulsive disorder (OCD) patients. Although serious adverse events can occur, only a few studies report on the safety profile of DBS for psychiatric disorders. In a prospective, open-label, interventional multi-center study, we examined the safety and efficacy of electrical stimulation in 30 patients with DBS electrodes bilaterally implanted in the anterior limb of the internal capsule.
View Article and Find Full Text PDFBackground: The Medtronic Registry for Epilepsy (MORE; Medtronic Inc, Dublin, Ireland) is an open label observational study evaluating the long-term effectiveness, safety, and performance of deep brain stimulation (DBS) of the anterior nucleus of thalamus (ANT) for the treatment of refractory epilepsy.
Objective: To compare the difference in success rate of placing contacts at ANT-target region (ANT-TR) between transventricular (TV) and extraventricular (EV) lead trajectories in 73 ANT-DBS implants in 17 European centers participating in the MORE registry.
Methods: The success rate of placing contacts at ANT-TR was evaluated using a screening method combining both individual patient imaging information and stereotactic atlas information to identify contacts at ANT-TR.
Background: In preparation for a multicenter study, a protocol was written on how to perform surgical targeting of the bed nucleus of the stria terminalis, based on the lead implantation experience in patients with treatment-refractory obsessive-compulsive disorder (OCD) at the Universitaire Ziekenhuizen Leuven (UZ Leuven). When analyzing the postoperative images, we were struck by the fact that the difference between the postoperative position of the leads and the planned position seemed larger than expected.
Methods: The precision of targeting in four patients with severe OCD who received bilateral model 3391 leads (Medtronic) was compared with the precision of targeting in the last seven patients who underwent surgery at UZ Leuven for movement disorders (four with Parkinson disease and three with essential tremor; all received bilateral leads).
Introduction: The most frequently used target for DBS in advanced Parkinson Disease (PD) is the sensorimotor subthalamic nucleus (STN), anatomically referred to as dorso-lateral STN [3]. Ambiguities arise, regarding the true meaning of this description in the STN. Does "dorsal" indicate posterior or superior? At its best, this definition assigns two directions in space to a three-dimensional structure.
View Article and Find Full Text PDFObjective: Because of the irreversibility of lesioning procedures and their possible side effects, we studied the efficacy of replacing bilateral anterior capsulotomy with chronic electrical capsular stimulation in patients with severe, long-standing, treatment-resistant obsessive-compulsive disorder.
Methods: We stereotactically implanted quadripolar electrodes in both anterior limbs of the internal capsules into six patients with severe obsessive-compulsive disorder. Psychiatrists and psychologists performed a double-blind clinical assessment.
Experienced neurosurgeons at eight spinal cord stimulation centers in the United States, Canada, and Europe participated in a study from 1997 to 2000 investigating the safety, performance, and efficacy of a Transverse Tripolar Stimulation (TTS) system invented at the University of Twente, the Netherlands. This device was proposed to improve the ability of spinal cord stimulation to adequately overlap paresthesia to perceived areas of pain. Fifty-six patients with chronic, intractable neuropathic pain of the trunk and/or limbs more than three months' duration (average 105 months) were enrolled with follow-up periods at 4, 12, 26, and 52 weeks.
View Article and Find Full Text PDFObjective: Because of the irreversibility of lesioning procedures and their possible side effects, we studied the efficacy of replacing bilateral anterior capsulotomy with chronic electrical capsular stimulation in patients with severe, long-standing, treatment-resistant obsessive-compulsive disorder.
Methods: We stereotactically implanted quadripolar electrodes in both anterior limbs of the internal capsules into six patients with severe obsessive-compulsive disorder. Psychiatrists and psychologists performed a double-blind clinical assessment.