Magnetoencephalography (MEG) has been revolutionised by optically pumped magnetometers (OPMs). "OPM-MEG" offers higher sensitivity, better spatial resolution, and lower cost than conventional instrumentation based on superconducting quantum interference devices (SQUIDs). Moreover, because OPMs are small, lightweight, and portable they offer the possibility of lifespan compliance and (with control of background field) motion robustness, dramatically expanding the range of MEG applications.
View Article and Find Full Text PDFBackground: Patient-maintained propofol TCI sedation (PMPS) allows patients to titrate their own target-controlled infusion (TCI) delivery of propofol sedation using a handheld button. The aim of this RCT was to compare PMPS with anaesthetist-controlled propofol TCI sedation (ACPS) in patients undergoing elective primary lower-limb arthroplasty surgery under spinal anaesthesia.
Methods: In this single-centre open-label investigator-led study, adult patients were randomly assigned to either PMPS or ACPS during their surgery.
Clear dental aligners are commonly manufactured using thermoplastic materials such as Duran and Durasoft. Using conventional thermoforming methods there are inherent disadvantages including time consumption and poor geometrical accuracies that often occur. The use of digital technologies and 3D printing techniques for producing dental aligners is often preferred where possible.
View Article and Find Full Text PDFEach year, many operations in the UK are performed with the patient awake, without the use of general anaesthesia. These include joint replacement procedures, and in order to reduce patient anxiety, the supervising anaesthetist delivers the sedative propofol intravenously using a target-controlled infusion (TCI) device. However, it is clinically challenging to judge the required effect-site concentration of sedative for an individual patient, resulting in patient care issues related to over or under-sedation.
View Article and Find Full Text PDFBackground: The clinical efficacy of effect-site targeted patient-maintained propofol sedation (PMPS) compared to anaesthetist-controlled propofol sedation (ACPS) for patients undergoing awake joint replacement surgery is currently unknown. There is no commercially available medical device capable of delivering PMPS so we have designed and built such a device. We plan a clinical trial to compare PMPS to ACPS and to collect data relating to the safety of our prototype device in delivering sedation.
View Article and Find Full Text PDFNanoparticles in the form nanotubes and nanoplatelets have been compared for von Mises stresses by using them as low-composition reinforcements in titanium alloy-based mandible plate for different compositions and orientations. A finite element model has been designed to reconstruct a fractured human mandible with a titanium alloy mandible plate. A 500 N compressive force was applied on the mandible, and stress distribution across the plate sections was analysed for aligned two-dimensional random and three-dimensional random orientations for both tubes and platelets.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
February 2019
Titanium alloy based maxillofacial plates and implants are widely used in fracture treatment and reconstructions. Filler materials Graphene Nanoplatlets(GNPs) were used in a Titanium alloy maxillofacial plate and a Finite Element Model (FEM) was designed to reconstruct a fractured human mandible. Both 50N and 500N bite forces were applied on the mandible and stress distribution using Von mises failure theory across the plate sections was analyzed.
View Article and Find Full Text PDF