As the COVID-19 pandemic impacts global populations, computed tomography (CT) lung imaging is being used in many countries to help manage patient care as well as to rapidly identify potentially useful quantitative COVID-19 CT imaging biomarkers. Quantitative COVID-19 CT imaging applications, typically based on computer vision modeling and artificial intelligence algorithms, include the potential for better methods to assess COVID-19 extent and severity, assist with differential diagnosis of COVID-19 versus other respiratory conditions, and predict disease trajectory. To help accelerate the development of robust quantitative imaging algorithms and tools, it is critical that CT imaging is obtained following best practices of the quantitative lung CT imaging community.
View Article and Find Full Text PDFWhile computed tomography (CT) is now commonly used and considered to be clinically valuable, significant DNA double-strand breaks (γ-H2AX foci) in white blood cells from adult and pediatric CT patients have been frequently reported. In this study to determine whether γ-H2AX foci and X-ray-induced naked DNA damage are suppressed by administration of the PrC-210 radioprotector, human blood samples were irradiated in a CT scanner at 50-150 mGy with or without PrC-210, and γ-H2AX foci were scored. X-ray-induced naked DNA damage was also studied, and the DNA protective efficacy of PrC-210 was compared against 12 other common "antioxidants.
View Article and Find Full Text PDFPurpose: To determine the effects of iterative reconstruction (IR) and high-frequency kernels on quantitative computed tomography (qCT) density measures at reduced X-ray dose.
Materials And Methods: The COPDGene 2 Phantom (CTP 698, The Phantom Laboratory, Salem, NY) with four embedded lung mimicking foam densities (12lb, 20lb, and 4lb), as well as water, air, and acrylic reference inserts, was imaged using a GE 64 slice CT750 HD scanner in helical mode with four current-time products ranging from 12 to 100 mAs. The raw acquired data were reconstructed using standard (STD - low frequency) and Bone (high frequency) kernels with filtered back projection (FBP), 100% ASiR, and Veo reconstruction algorithms.
This article explains a method for creating CT protocols for a wide range of patient body sizes and clinical indications, using detailed tube current information from a small set of commonly used protocols. Analytical expressions were created relating CT technical acquisition parameters which can be used to create new CT protocols on a given scanner or customize protocols from one scanner to another. Plots of mA as a function of patient size for specific anatomical regions were generated and used to identify the tube output needs for patients as a function of size for a single master protocol.
View Article and Find Full Text PDFThe purpose of this paper is to describe our experience with the AAPM Medical Physics Practice Guideline 1.a: "CT Protocol Management and Review Practice Guideline". Specifically, we will share how our institution's quality management system addresses the suggestions within the AAPM practice report.
View Article and Find Full Text PDFPurpose: CT radiation exposure has come under increasing scrutiny because of dramatically increased utilization. Multiphase CT studies (repeated scanning before and after contrast injection) are a potentially important, overlooked source of medically unnecessary radiation because of the dose-multiplier effect of extra phases. The purpose of this study was to determine the frequency of unindicated multiphase scanning and resultant excess radiation exposure in a sample referral population.
View Article and Find Full Text PDFThe VetMousetrap, a novel device that allows computed tomography (CT) of awake cats and provides a clinically supportive environment, is described. Ten normal cats were used to test the device for ambient internal oxygen, carbon dioxide levels, and temperature. Twenty-two awake normal cats were imaged using a 16-multislice helical CT unit to evaluate dose-equivalent protocols.
View Article and Find Full Text PDFPurpose: To evaluate the clinical usefulness of volumetric analysis at nonenhanced computed tomography (CT) as the sole method with which to follow up endovascular abdominal aortic aneurysm repair (EVAR) and to identify endoleaks causing more than 2% volumetric increase from the previous volume determination.
Materials And Methods: The study had institutional review board approval. Images were reviewed retrospectively in a HIPAA-compliant manner for 230 CT studies in 70 patients (11 women, 59 men; mean age, 74 years) who underwent EVAR.