Predictors of rebound after correction of coronal plane deformities using temporary hemiepiphysiodesis (TH) are not well defined. The following research questions were tested: (1) Is the dynamic knee joint load useful to improve rebound prediction accuracy? (2) Does a large initial deformity play a critical role in rebound development? (3) Are BMI and a young age risk factors for rebound? Fifty children and adolescents with idiopathic knee valgus malalignment were included. A deviation of the mechanical femorotibial angle (MFA) of ≥ 3° into valgus between explantation and the one-year follow-up period was chosen to classify a rebound.
View Article and Find Full Text PDF: Even minor adverse reactions after total hip replacement (THR), including lymphedema, postoperative leg swelling, and blood loss, compromise patient comfort in times of minimally invasive fast-track surgery. Compression dressings are commonly used in surgical practice to reduce swelling or blood loss. However, the use of spica hip compression dressings after primary THR is controversial, and prospective studies are lacking.
View Article and Find Full Text PDFThe symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer.
View Article and Find Full Text PDFPreparation of the femoral proximal medullary cavity by reaming is essential for intramedullary nail osteosynthesis and hip revision arthroplasty. The use of reamers sometimes exerts high torsional forces on the bone. Design and direction of rotation of the reamer are potential influencing factors.
View Article and Find Full Text PDFBackground: Restoring the ability to walk with a prosthesis is considered a fundamental rehabilitation goal after transfemoral amputation. An essential prerequisite for achieving this goal is adequate force transmission between the prosthesis and the body. Does bone anchorage of an artificial limb permit a more normal force transmission?
Methods: Data of 15 healthy subjects, nine amputees fitted with bone-anchored prostheses, nine amputees using socket prostheses, and 18 patients with a total hip replacement were included in this multicenter, observational study.
High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial opening osteotomy has prevailed over the past decades. The objective of the present study was to determine whether anteromedially positioned small plates are nevertheless forgiving under biomechanically unfavourable conditions (overcorrection and lateral hinge fracture).
View Article and Find Full Text PDFEffects of hydroxyapatite (HA) particles with bone morphogenetic BMP-2 or GDF-5 were compared in sheep lumbar osteopenia; in vitro release in phosphate-buffered saline (PBS) or sheep serum was assessed by ELISA. Lumbar (L) vertebral bone defects (Ø 3.5 mm) were generated in aged, osteopenic female sheep ( = 72; 9.
View Article and Find Full Text PDFArch Orthop Trauma Surg
March 2023
Introduction: Implant loosening is the most common indication for revision after total hip arthroplasty and is associated with progressive bone destruction. Contained defects can be treated with impaction bone grafting (IBG). Segmental defects are successfully restored with metal augmentation.
View Article and Find Full Text PDF(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically.
View Article and Find Full Text PDFUnlabelled: There are multiple attempts to decrease costs in the healthcare system while maintaining a high treatment quality. Digital therapies receive increasing attention in clinical practice, mainly relating to home-based exercises supported by mobile devices, eventually in combination with wearable sensors. The aim of this study was to determine if patients following total hip arthroplasty (THA) could benefit from gait training on crutches conducted by a mobile robot in a clinical setting.
View Article and Find Full Text PDFBackground: Optimized temporal and spatial activation of the gluteal intermuscular functional unit is essential for steady gait and minimized joint loading.
Research Question: To analyze the temporal relationship between spatially resolved surface EMG (SEMG) of the gluteal region and the corresponding ground reaction force (GRF).
Methods: Healthy adults (29♀; 25♂; age 62.
Background: Whilst traumatology around elderly population becomes more and more popular nowadays, the knowledge of local bone quality prior to osteosynthesis is of paramount importance. Assessment of the local bone mechanical properties provides essential information related to implant stability and can support treatment strategies in a timely manner. In the acute setting, dual-energy X-ray absorptiometry and quantitative computer tomography cannot be used routinely, and up till now no known intraoperative methods have been established.
View Article and Find Full Text PDFBackground: Cut-out of gamma nail often results from poor primary bone stability, suboptimal reduction (varus) and excentric placement of the head element which may lead to "instability" and frequently requires revision. Various studies have shown that augmentation with polymethylmethacrylate cement increases the primary stability of osteosynthesis. However, it has not yet been widely used in fracture treatment due to certain disadvantages, e.
View Article and Find Full Text PDFBackground: Posttraumatic maltorsion and implant failure after closed reduction of proximal femoral fractures remain a cause of concern. Although the reproducibility of torsion measuring techniques on CT for femoral shaft fractures has been thoroughly analyzed, little is known about the trochanteric fractures. Apart from the well-known CT limitations, posttraumatic alteration of bony landmarks makes torsional assessment even more challenging.
View Article and Find Full Text PDFIntroduction: The increasing number of geriatric traumatology cases has intensified the need to reliably and objectively evaluate local bone quality, the latter poses a decisive factor for the choice of an optimal approach to treat osteoporotic fractures. Osteodensitometry imaging techniques are not routinely available in acute operative settings, nor do they provide objective information on local bone properties specifically needed for the prognosis of implant stability.
Materials And Methods: This study sought to verify ex vivo the feasibility and sensitivity of a novel method for the determination of local bone strength in the acute operative setting (intraoperative osseomechanical strength measurement; IOSM) that is based on the principle of material displacement resistance against the force of a rotary indenter.
Objective: To investigate a stem-adjusted preparation of the femur with a kinked reamer and to determine whether this approach results in higher primary stability of a kinked stem than straight reaming of the intramedullary canal.
Methods: Ten cementless stems with a kinked design were implanted in synthetic femurs after preparation of the femoral canal with 2 different reamer designs (straight reaming [SR] group vs kinked reaming [KR] group). The specimens were analyzed using CT to determine the anchoring length and examined with a mechanical testing system to establish their axial stiffness, torsional stiffness, and migration distance after 10 000 gait cycles.
Background: Easy revisability is gaining increasingly in importance. The removal of well-fixed cemented stems is very demanding and is often associated with increased operative morbidity. Implant design may be here a decisive impact factor, and the best way to ascertain it is experimentally.
View Article and Find Full Text PDFGuteal muscle activation during walkway and treadmill walking was compared by means of Surface EMG (SEMG). Healthy older adults (50-75 years, n = 54; 29 females, 25 males) walked on a walkway (WW) at their self-selected slow, normal, and fast walking speeds and on a treadmill (TM) at 2, 3, 4, 5, and 6 km/h. Subject-individual, best-matched speed pairs were constituted and named SLOW, NORMAL, and FAST.
View Article and Find Full Text PDFBackground: According to literature, more than 30% of revised knee arthroplasties will require at least one re-revision. Practical experience has shown that there are considerable product-specific differences in the explantability of cemented long-stem prostheses. In the registers of successful implants, stem geometry varies considerably between the manufacturers.
View Article and Find Full Text PDFAlthough cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless press-fit stems of 4 different designs were implanted in synthetic femurs.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
August 2018
Introduction: The use of Kinesio tape (KT) to improve proprioception is a matter of considerable debate. In comparison, the rupture of the anterior cruciate ligament is a sufficiently well-investigated injury with a proven compromise of proprioception. The objective of the present study was to assess a supportive effect on proprioception after KT application, taking the anterior cruciate ligament (ACL) rupture as an example.
View Article and Find Full Text PDFPurpose: Although the spacer block technique has been recommended for the implantation of unicompartmental knee arthroplasty (UKA), there is still a lack of data concerning the resulting component positioning.
Methods: This retrospective study included 193 consecutive patients who had undergone medial UKA using the spacer technique. On the basis of the postoperative long standing radiographs, the coronal component alignment was determined in relation to the mechanical axes and the sagittal component alignment in relation to the anatomical axes of the tibia and femur.
Up till now, only a weak connection could be shown between patient-related outcome measures (PROMs) and measurements obtained by gait analysis (e.g. speed, step length, cadence, ground reaction force, joint moments and ranges of motion) after total knee arthroplasty (TKA).
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2018
Introduction: The number of revision hip arthroplasties being performed is growing and implantation of a cementless stem has become established as the gold standard. For producing a primary stability, the press-fit procedure is the method of choice, but also can be achieved by multiple-point impactions. Specific femoral stems should follow the anatomical shape and provide a more extensive anchorage.
View Article and Find Full Text PDFBackground: The most common reason for revision total hip arthroplasty remains polyethylene wear. Development dysplasia of the hip and revision situations requires a conscious compromise of implant position. The surgeon should know about the consequence on wear via a possible change in hip contact force.
View Article and Find Full Text PDF