Improving the adaptation of resin composites during placement is necessary to increase durability and reduce microleakage. Flowable resin liners have been introduced to improve adaptation in composite restorations. In addition, a device that lowers the viscosity of regular dental composites has been introduced (Calset, AdDent Inc, Danbury, CT, USA).
View Article and Find Full Text PDFAntioxidants from a blueberry beverage may impact plasma vitamins. We examined vitamins/food selection in 12 college athletes during 30 days compared with placebo. Blood was collected before and after exercise at the beginning of the study (day 1) and then after a 30-day period of taking a daily supplemental beverage (day 30).
View Article and Find Full Text PDFOral Surg Oral Med Oral Pathol Oral Radiol Endod
April 2005
Objective: This study compared the accuracy of D- and F-speed intraoral radiographs and digital and enhanced digital radiographic images for endodontic file length determination.
Study Design: Size 15 K-files were bonded in 51 canals of 34 human cadaver teeth. The distance from file tip to root apex was measured on D- and F-speed film and on unenhanced and enhanced digital images.
Polishing composite restorations at recall prophylaxis may affect their surface roughness. This investigation evaluated the effect of prophy paste on the surface roughness of a microfilled (Filtek A110) and a microhybrid (Filtek Z250) resin composite before and after simulated toothbrushing. Twenty, two-sided samples of both materials were fabricated in acrylic molds against a Mylar strip (baseline).
View Article and Find Full Text PDFThis study evaluated the effects of two finishing techniques and pumice polishing on the surface roughness of eight different provisional materials. Provisional materials included polymethylmethacrylate-based Alike, Snap, Trim and Jetand composite-based provisional materials Temphase, Protemp 3 Garant, Luxatemp and Integrity. Baseline surface roughness was measured by a profilometer, then the provisional materials were finished using extra fine acrylic burs or medium abrasive disks.
View Article and Find Full Text PDFOral Surg Oral Med Oral Pathol Oral Radiol Endod
July 2003
Objectives: We sought to compare the sensitometric characteristics of 3 intraoral film types processed in an automated roller solution with the characteristics of the films processed in 4 automated nonroller solutions.
Study Design: Eastman Kodak Ultra-Speed, Flow X-ray EV-57, and Eastman Kodak InSight films were exposed to varying levels of radiation and processed in 1 automated roller solution and in 4 nonroller solutions. Speed and contrast were measured at various density levels and ranges.
A prospective in vivo investigation was conducted to determine radiographic and clinical factors associated with contemporary nonsurgical endodontic retreatments. Approximately 1,100 failing endodontically treated teeth were screened to determine an appropriate treatment plan. Using magnification, 337 consecutive retreatment cases were evaluated and treated.
View Article and Find Full Text PDFFlowable resin materials have been suggested as liners beneath packable composites to improve marginal integrity. This investigation evaluated the effect of low-viscosity liners on microleakage in Class II packable composite restorations. Twenty Class II cavities were prepared in extracted third molars for each of four packable composites (Heliomolar HB, Prodigy Condensable, Surefil and Tetric Condense).
View Article and Find Full Text PDFIn response to interest by dental students and patient needs, an elective program in implant dentistry was started at the University of Detroit Mercy School of Dentistry (UDM) in the summer of 1994. The 1-year program is offered to a group of 10 senior students out of a class of 72. Implant treatment is provided to selected edentulous and partially edentulous patients.
View Article and Find Full Text PDF