Publications by authors named "Francois de L'escaille"

An international team that included 20 independent laboratories from biopharmaceutical companies, universities, analytical contract laboratories and national authorities in the United States, Europe and Asia was formed to evaluate the reproducibility of sample preparation and analysis of N-glycans using capillary electrophoresis of 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled glycans with laser induced fluorescence (CE-LIF) detection (16 sites) and ultra high-performance liquid chromatography (UHPLC, 12 sites; results to be reported in a subsequent publication). All participants used the same lot of chemicals, samples, reagents, and columns/capillaries to run their assays. Migration time, peak area and peak area percent values were determined for all peaks with >0.

View Article and Find Full Text PDF

A collaborative study on the robustness and portability of a capillary electrophoresis-mass spectrometry method for peptide mapping was performed by an international team, consisting of 13 independent laboratories from academia and industry. All participants used the same batch of samples, reagents and coated capillaries to run their assays, whereas they utilized the capillary electrophoresis-mass spectrometry equipment available in their laboratories. The equipment used varied in model, type and instrument manufacturer.

View Article and Find Full Text PDF

Biomarker analysis is pivotal for disease diagnosis and one important class of biomarkers is constituted by proteins and peptides. This review focuses on protein and peptide analyses from biological fluids performed by capillary electrophoresis. The various strategies that have been reported to prevent difficulties due to the handling of real samples are described.

View Article and Find Full Text PDF

Capillary zone electrophoresis (CZE) in fused-silica capillaries is an effective analytical approach for the separation and determination of the transferrin (Tf) isoforms and thus carbohydrate-deficient transferrin (CDT) in human serum. Sera of patients with progressed liver cirrhosis are prone to interferences in the beta region which prevent the proper determination of CDT by CZE without additional sample preparation. Efforts to identify, reduce or even eliminate these interferences have been undertaken.

View Article and Find Full Text PDF

The double coating principle of CEofix buffers was evaluated for the analysis of some basic drugs by capillary electrophoresis-diode-array detection (CE-DAD) and capillary electrophoresis-mass spectrometry (CE-MS). The involatile phosphate present in original low pH CEofix, was replaced with formic acid for hyphenation of CE with MS. The double coating produces a substantial and highly reproducible electroosmotic flow (EOF), even at low pH.

View Article and Find Full Text PDF

Background: Measurements of carbohydrate-deficient transferrin (CDT) are used as markers of alcohol abuse. We developed a capillary zone electrophoresis (CZE) method aimed at improving accuracy of CDT testing.

Methods: We studied 111 alcohol abusers with Alcohol Use Disorders Identification Test scores >11 and 50 teetotalers.

View Article and Find Full Text PDF