Electrochemical energy storage systems based on sulfur and lithium can theoretically deliver high energy with the further benefit of low cost. However, the working mechanism of this device involves the dissolution of sulfur to high-molecular weight lithium polysulfides (LiPs with general formula LiS, n≥4) in the electrolyte during the discharge process. Therefore, the resulting migration of partially dissociated LiPs by diffusion or under the effect of the electric field to the lithium anode, activates an internal shuttle mechanism, reduces the active material and in general leads to loss of performance and cycling stability.
View Article and Find Full Text PDFThis work aimed to develop an easy-to-use smartphone-based electrochemical biosensor to quickly assess a coffee blend's total polyphenols (Phs) content at the industrial and individual levels. The device is based on a commercial carbon-based screen-printed electrode (SPE) modified with multi-walled carbon nanotubes (CNTs) and gold nanoparticles (GNPs). At the same time, the biological recognition element, Laccase from , Lac, was immobilized on the sensor surface by using glutaraldehyde (GA) as a cross-linking agent.
View Article and Find Full Text PDFOne of the main problems in developing immunosensors featuring carbon nanotubes (CNTs) is immobilizing antibodies (Abs) onto the CNT surface to afford selective binding to target antigens (Ags). In this work, we developed a practical supramolecular Ab conjugation strategy based on resorc[4]arene modifiers. To improve the Ab orientation on the CNTs surface and optimizing the Ab/Ag interaction, we exploited the host-guest approach by synthesizing two newly resorc[4]arene linkers R1 and R2 via well-established procedures.
View Article and Find Full Text PDFIn recent years, several efforts have been made to develop selective, sensitive, fast response, and miniaturized immunosensors with improved performance for the monitoring and screening of analytes in several matrices, significantly expanding the use of this technology in a broad range of applications. However, one of the main technical challenges in developing immunosensors is overcoming the complexity of binding antibodies (Abs) to the sensor surface. Most immobilizing approaches lead to a random orientation of Abs, resulting in lower binding site density and immunoaffinity.
View Article and Find Full Text PDFWe report a new sensitive label-free electrochemical immunosensor to detect Vitamin D (25-OHD) in untreated serum samples. To this aim, a graphite screen printed electrode (SPE) was modified using cysteamine (CYM) functionalized core-shell magnetic nanoparticles (Au@MNPs) then, the 25-OHD antibody (AbD) was immobilized via glutaraldehyde crosslinking. The several steps involved in the immunosensor development and 25-OHD analysis were monitored by using differential pulse voltammetry (DPV).
View Article and Find Full Text PDFThis work presents the realization of a label-free electrochemical immunosensor for the quick, cheap, and straightforward determination of atrazine. This biodevice is based on developing a technological platform where a gold screen printed electrode (Au-SPE) surface was modified by the electrodeposition of a highly porous gold layer. As an internal probe redox, a Prussian Blue thin layer (PB) was then electrosynthetized onto the modified Au-SPE.
View Article and Find Full Text PDFLignin nanoparticles (LNPs) acted as a renewable and efficient platform for the immobilization of horseradish peroxidase (HRP) and glucose oxidase (GOX) by a layer by layer procedure. The use of concanavalin A as a molecular spacer ensured the correct orientation and distance between the two enzymes as confirmed by Förster resonance energy transfer measurement. Layers with different chemo-physical properties tuned in a different way the activity and kinetic parameters of the enzymatic cascade, with cationic lignin performing as the best polyelectrolyte in the retention of the optimal Con A aggregation state.
View Article and Find Full Text PDFOne of the main problems in the development of immunosensors is to overcome the complexity of binding antibodies to the sensor surface. Most immobilizing methods lead to a random orientation of antibodies with a lower binding site density and immunoaffinity. In order to control the orientation of antibody immobilization, several resorc[4]arene derivatives were designed and synthesized.
View Article and Find Full Text PDFA single-use electrochemical screen-printed electrode is reported based on biomimetic properties of nanoceria particles (CeNPs). The developed tool showed an easy approach compared to the classical spectrophotometric methods reported in literature in terms of ease of use, cost, portability, and unnecessary secondary reagents. The sensor allowed the detection of the total antioxidant capacity (TAC) in wine samples.
View Article and Find Full Text PDFIn this study, polythiophene copolymers have been used as modifier for electrode surfaces in order to allow the immobilization of active pyrroloquinoline quinone dependent glucose dehydrogenase (PQQ-GDH) and to simultaneously improve the direct electrical connection of the enzyme with the electrode. Polymer films are electrosynthesized in aqueous solution without the need of surfactants onto carbon nanotubes modified gold electrodes from mixtures of 3-thiopheneacetic acid (ThCHCOH) and 3-methoxythiophene (ThOCH) using a potentiostatic pulse method. Polythiophene deposition significantly improves the bioelectrocatalysis of PQQ-GDH: the process starts at - 200 mV vs.
View Article and Find Full Text PDFIn this work a detailed description of the development of amine oxidase-based electrochemical biosensors for the selective determination of the biogenic amines is presented. The enzymes required for this operation are Polyamine Oxidase (PAO) and Spermine Oxidase (SMO) which are physically entrapped in poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ), a photo-cross-linkable gel, onto screen printed electrode (SPE) surface. The developed biosensors are deeply characterized in the analysis of biogenic amines by using flow injection amperometric (FIA) technique.
View Article and Find Full Text PDFIn this research, we developed a direct-flow surface plasmon resonance (SPR) immunosensor for ampicillin to perform direct, simple, and fast measurements of this important antibiotic. In order to better evaluate the performance, it was compared with a conventional amperometric immunosensor, working with a competitive format with the aim of finding out experimental real advantages and disadvantages of two respective methods. Results showed that certain analytical features of the new SPR immunodevice, such as the lower limit of detection (LOD) value and the width of the linear range, are poorer than those of a conventional amperometric immunosensor, which adversely affects the application to samples such as natural waters.
View Article and Find Full Text PDFElectrochemical biosensors provide an attractive means of analyzing the content of a biological sample due to the direct conversion of a biological event to an electronic signal. The signal transduction and the general performance of electrochemical biosensors are often determined by the surface architectures that connect the sensing element to the biological sample at the nanometer scale. The most common surface modification techniques, the various electrochemical transduction mechanisms, and the choice of the recognition receptor molecules all influence the ultimate sensitivity of the sensor.
View Article and Find Full Text PDFA catalase-based (NAF/MWCNTs) nanocomposite film modified glassy carbon electrode for hydrogen peroxide (HO) detection was developed. The developed biosensor was characterized in terms of its bioelectrochemical properties. Cyclic voltammetry (CV) technique was employed to study the redox features of the enzyme in the absence and in the presence of nanomaterials dispersed in Nafion® polymeric solution.
View Article and Find Full Text PDFTraditional cleaning methods with organic solvents often are not suitable for removal of aged resin so researchers have to find new formulations. In this work, a case study is reported in which new microemulsions were applied on the surface of a painting covered by some aged resin layers used during a previous restoration. Based on the quality of the intervention and the analysis of a sample of the varnish carried out with both MALDI-TOF and ATR-IR spectrometers, it was conjectured that this undesired material could be an acrylic polymer.
View Article and Find Full Text PDFIn this work, we developed an impedimetric label-free immunosensor for the detection of 2,4-Dichlorophenoxy Acetic Acid (2,4-D) herbicide either in standard solution and spiked real samples. For this purpose, we prepared by electropolymerization a conductive polymer poly-(aniline-co-3-aminobenzoic acid) (PANABA) then we immobilized anti-2,4-D antibody onto a nanocomposite AuNPs-PANABA-MWCNTs employing the carboxylic moieties as anchor sites. The nanocomposite was synthesized by electrochemical polymerization of aniline and 3-aminobenzoic acid, in the presence of a dispersion of gold nanoparticles, onto a multi-walled carbon nanotubes-based screen printed electrode.
View Article and Find Full Text PDFIn the last decades, in vitro diagnostic devices (IVDDs) became a very important tool in medicine for an early and correct diagnosis, a proper screening of targeted population, and also assessing the efficiency of a specific therapy. In this review, the most recent developments regarding different configurations of surface plasmon resonance affinity biosensors modified by using several nanostructured materials for in vitro diagnostics are critically discussed. Both assembly and performances of the IVDDs tested in biological samples are reported and compared.
View Article and Find Full Text PDFIn this study, we report the development of an SPR (Surface Plasmon Resonance) immunosensor for the detection of ampicillin, operating under flow conditions. SPR sensors based on both direct (with the immobilization of the antibody) and competitive (with the immobilization of the antigen) methods did not allow the detection of ampicillin. Therefore, a sandwich-based sensor was developed which showed a good linear response towards ampicillin between 10(-3) and 10(-1) M, a measurement time of ≤20 min and a high selectivity both towards β-lactam antibiotics and antibiotics of different classes.
View Article and Find Full Text PDFAu nanocorals are grown on gold screen-printed electrodes (SPEs) by using a novel and simple one-step electrodeposition process. Scanning electron microscopy was used for the morphological characterization. The devices were assembled on a three-electrode SPE system, which is flexible and mass producible.
View Article and Find Full Text PDFIn this work, several theoretical aspects involved in the first-generation inhibition-based electrochemical biosensor measurements have been discussed. In particular, we have developed a theoretical-methodological approach for the characterization of the kinetic interaction between alkaline phosphatase (AlP) and 2,4-dichlorophenoxy acetic acid (2,4-D) as representative inhibitor studied by means of cyclic voltammetry and amperometry. Based on these findings, a biosensor for the fast, simple, and inexpensive determination of 2,4-D has been developed.
View Article and Find Full Text PDFThe aim of this work is to show how the integration of gold nanoparticles (AuNPs) into multi-wall-carbon-nanotubes (MWCNTs) based screen-printed electrodes and into graphene-based screen-printed electrodes (GPHs) could represent a potential way to further enhance the electrochemical properties of those electrodes based on nanoparticles. Laccase from (TvL) was immobilized over MWCNTs and GPH previously modified with AuNPs (of 5 and 10 nm). The characterization of the modified electrode surface has been carried out by cyclic voltammetry.
View Article and Find Full Text PDFNafion, an ion exchange polymer that is very resistant to chemical attack, even by strong oxidant at high temperatures, has found great increasing use as a film material; however, its use as immobilizing agent in third-generation biosensors is hindered due to the low rate of charge transfer in the pure Nafion film. In this work we showed that the use of functionalized multi-walled carbon nanotubes Nafion/MWCNTs composite film for modification of the carbon-based electrode surfaces would increase the charge transfer rate greatly; the composite has proven to efficiently immobilize two different heme proteins (catalase and cytochrome c) and to enhance the electrochemical performances of several carbon electrode materials (glassy carbon, mesoporous graphite, graphite and graphene) either used as classical electrodes or screen printed ones. The electrochemical signal of both redox proteins becomes more reversible and the electron transfer kinetic constant increases.
View Article and Find Full Text PDFA detailed comparison was made of the analytical features of a new Surface Plasmon Resonance (SPR) immunodevice for triazine pesticide determination with those of two other amperometric (conventional and screen-printed) immunosensors and the advantages and disadvantages of the SPR method were thoroughly investigated. For conventional amperometric and screen-printed devices, "competitive" assays were used; conversely, the SPR transduction technique allowed a "direct" measurement format to be used. As far as the main analytical data are concerned, the SPR method does not seem to offer substantial advantages.
View Article and Find Full Text PDF