Publications by authors named "Francisco Quiroz"

Article Synopsis
  • Ataxia-telangiectasia (AT) is a rare genetic disorder causing neurological issues, blood vessel irregularities, and a weakened immune system, particularly noted in Latin American patients.
  • A study involving 218 patients revealed that the average age for symptoms and diagnosis is about 1 year and 5 years, respectively, with common recurrent airway infections linked to IgA deficiency.
  • The study found a mean survival of 24.2 years, with a 20-year survival rate of 52.6%, and higher mortality rates in females and those with low IgG levels, highlighting the importance of assessing immune function in AT patients.
View Article and Find Full Text PDF

Microbial diseases have been declared one of the main threats to humanity, which is why, in recent years, great interest has been generated in the development of nanocomposites with antimicrobial capacity. The present work studied two magnetic nanocomposites based on graphene oxide (GO) and multiwall carbon nanotubes (MWCNTs). The synthesis of these magnetic nanocomposites consisted of three phases: first, the synthesis of iron magnetic nanoparticles (MNPs), second, the adsorption of the photosensitizer menthol-Zinc phthalocyanine (ZnMintPc) into MWCNTs and GO, and the third phase, encapsulation in poly (N-vinylcaprolactam-co-poly(ethylene glycol diacrylate)) poly (VCL-co-PEGDA) polymer VCL/PEGDA a biocompatible hydrogel, to obtain the magnetic nanocomposites VCL/PEGDA-MNPs-MWCNTs-ZnMintPc and VCL/PEGDA-MNPs-GO-ZnMintPc.

View Article and Find Full Text PDF

In this work, monodisperse BiFeO nanoparticles with a particle diameter of 5.5 nm were synthesized by a nanocasting technique using mesoporous silica SBA-15 as a hard template and pre-fabricated metal carboxylates as metal precursors. To the best of our knowledge, the synthesized particles are the smallest BiFeO particles ever prepared by any method.

View Article and Find Full Text PDF

Single-wavelength fluorescent reporters allow visualization of specific neurotransmitters with high spatial and temporal resolution. We report variants of intensity-based glutamate-sensing fluorescent reporter (iGluSnFR) that are functionally brighter; detect submicromolar to millimolar amounts of glutamate; and have blue, cyan, green, or yellow emission profiles. These variants could be imaged in vivo in cases where original iGluSnFR was too dim, resolved glutamate transients in dendritic spines and axonal boutons, and allowed imaging at kilohertz rates.

View Article and Find Full Text PDF

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery.

Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study.

View Article and Find Full Text PDF

Background: Intraoperative frozen section (FS) often is performed in patients who undergo thyroid lobectomy to determine the need for completion thyroidectomy. At our institution, if FS pathology is benign, final pathology is expedited overnight. The aim of this study was to determine the utility of FS and to identify a cost-effective management algorithm for thyroid lobectomy.

View Article and Find Full Text PDF

Pancreas transplantation aims to restore physiologic normoglycemia in diabetic patients with glomerulopathy and avoid or delay the onset of diabetic retinopathy and arteriopathy. Simultaneous pancreas-kidney transplant is the most common approach, using a cadaveric pancreas donation in conjunction with either cadaveric or live donor renal transplant. Alternative techniques include pancreas after kidney transplant, in which the pancreas transplant is performed some years after renal transplant.

View Article and Find Full Text PDF

Background: Preoperative ultrasonography (US) is recommended in all patients with differentiated thyroid cancer (DTC) to evaluate for clinically occult metastatic lymphadenopathy. The purpose of this study was to examine the influence of preoperative US findings on the initial operative management of patients with DTC.

Methods: This is a retrospective review of 70 patients with biopsy-proven DTC who underwent total thyroidectomy between February 2010 and January 2012.

View Article and Find Full Text PDF

Background: For patients with primary hyperparathyroidism (pHPT), imaging studies are obtained to facilitate minimally invasive parathyroidectomy. If imaging studies are nonlocalizing, it is not known if exploration should begin on a particular side or gland location.

Study Design: A retrospective review of a prospective parathyroid database was performed.

View Article and Find Full Text PDF

Sonography is the recommended initial imaging test in the evaluation of patients presenting with right upper quadrant pain or jaundice. Dependent upon clinical circumstances, the differential diagnosis includes choledocholithiasis, biliary stricture, or tumor. Sonography is very sensitive in detection of mechanical biliary obstruction and stone disease, although less sensitive for detection of obstructing tumors, including pancreatic carcinoma and cholangiocarcinoma.

View Article and Find Full Text PDF

Purpose: We report our experience with LC for small renal tumors.

Materials And Methods: Patients who underwent LC at our institution between February 2000 and September 2004 were included in the study. A retrospective chart review was done for perioperative and postoperative parameters as well as clinical outcomes.

View Article and Find Full Text PDF

Objective: To review our experience in managing the uncommon problem of a retained Foley catheter secondary to an inability to deflate the catheter balloon.

Methods: A chart review of 13 patients in whom it was not possible to deflate their Foley catheter balloons was performed. We review the various techniques used to deflate their catheter balloons and present a modified algorithm.

View Article and Find Full Text PDF

Sonography is the imaging modality of choice in detecting and characterizing pathologic conditions affecting the extratesticular space. Although most abnormalities are benign, many may simulate or represent malignant processes. Accurate diagnosis is therefore essential and must be based not only on the sonographic findings but also on accurate clinical history and physical examination findings.

View Article and Find Full Text PDF

Pulmonary embolism (PE) and deep venous thrombosis (DVT) represent two manifestations of the same syndrome, venous thromboembolism. Contrast-enhanced computed tomography (CT) angiography is a practical, efficient alternative to conventional imaging for PE. Following the pulmonary examination, the inferior vena cava (IVC) and the iliac, femoral, and popliteal veins can be studied with CT without additional intravenous contrast administration.

View Article and Find Full Text PDF