Percutaneous intervention in anomalous coronary arteries originating from the opposite sinus of Valsalva is complicated by their unusual location and course, which makes selective cannulation difficult. The GuideLiner (Vascular Solutions, Inc.) is a monorail guide extension catheter designed to advance beyond the tip of a mother guide catheter to enable deep intubation of a coronary artery, provide extra support, and improve coaxial alignment.
View Article and Find Full Text PDFPercutaneous intervention in the context of coronary artery ectasia (CAE) is penalized with no-reflow phenomenon. The glycoprotein-IIb/IIIa-inhibitor abciximab was the most accepted method for pharmacology thrombus resolution in this scenario, nevertheless, this agent was recently withdrawn. We describe 5 patients treated with local intracoronary fibrinolysis administrated through predesigned catheters in the setting of AMI and CAE.
View Article and Find Full Text PDFCardiovasc Revasc Med
February 2021
Vascular complications during transcatheter aortic valve implantation (TAVI) are relatively common, and some of them related to the transfemoral secondary access. The use of the transradial access (TRA) as an alternative vascular approach for transfemoral TAVI could reduce these complications, however, the treatment of potential vascular peripheral issues from this access has been scarcely described. The advance of a wire from the TRA to the primary transfemoral access at the beginning of the procedure could help the management of eventual vascular complications.
View Article and Find Full Text PDFTopical application of drops containing ocular drugs is the preferred non-invasive route to treat diseases that affect the anterior segment of the eye. However, the formulation of eye drops is a major challenge for pharmacists since the access of drugs to ocular tissues is restricted by several barriers. Acetazolamide (ACZ) is a carbonic anhydrase inhibitor used orally for the treatment of ocular hypertension in glaucoma.
View Article and Find Full Text PDFCardiovasc Revasc Med
November 2019
Objectives: The aim of this study is to determine the relation between the valve depth implantation and the new-onset left bundle branch block (LBBB) in patients treated with transcatheter aortic valve implantation (TAVI) using Edwards Sapien 3 (S3) prosthesis.
Background: LBBB is the most common conduction disturbance after TAVI. The S3 has been associated with a higher incidence of LBBB.
The theory of self-determination establishes the existence of three basic psychological needs (autonomy, competence, and relationship). If these needs are satisfied, optimal personal well-being will be achieved. The (BNSSS) is a measurement developed to evaluate these needs within the sporting context.
View Article and Find Full Text PDFIntroduction And Objectives: Transcatheter aortic-valve implantation (TAVI) is an accepted treatment for patients with severe aortic stenosis and high surgical risk. However, there is lack in data about TAVI in low-risk patients that are already being treated with this therapy in some clinical contexts.
Methods: A retrospective analysis of patients treated with transfemoral TAVI using Edwards Sapien prosthesis in one center was performed, classifying the patients into three groups according to the surgical risk (high/intermediate/low risk for STS score>8/4-8/<4).
Congenital atresia of the left main coronary artery (LMCA) is one of the rarest congenital anomalies, which may have an unfavorable prognosis leading to myocardial ischemia, ventricle dysfunction or even sudden cardiac death. There are 34 cases of LMCA in adults reported in the literature, most of them successfully treated with coronary revascularization. We report the case of an adult with LMCA who presented with terminal heart failure that required biventricular assistance and heart transplant.
View Article and Find Full Text PDF