Conventional needle insertion training relies on medical dummies that simulate surface anatomy and internal structures such as veins or arteries. These dummies offer an interesting space to augment with useful information to assist training practices, namely, internal anatomical structures (subclavian artery and vein, internal jugular vein and carotid artery) along with target point, desired inclination, position and orientation of the needle. However, limited research has been conducted on Optical See-Through Augmented Reality (OST-AR) interfaces for training needle insertion, especially for central venous catheterization (CVC).
View Article and Find Full Text PDFWhile most functional MRI studies using exogenous contrast agent employ gradient-echo (GE) signal, spin echo (SE) imaging would represent an attractive alternative if its detection power were more comparable with GE imaging. This study demonstrates that SE methods systematically underestimate functional changes in microvascular cerebral blood plasma volume (CBV), so that SE detection power in brain tissue cannot match that provided by GE signal. Empirically, the in vivo response of SE-CBV was about 40% smaller than that of GE-CBV in rat brain at low basal values of CBV, a result that is consistent with physics predictions under the simplifying assumption of uniform vessel dilation.
View Article and Find Full Text PDFDespite many desirable characteristics, event-related (ER) stimulus designs for BOLD and IRON suffer from low detection power relative to block designs because the hemodynamic impulse response function (IRF) acts as a low-pass filter on neural activation to attenuate the size of differential responses to alternate stimuli. While the use of exogenous contrast agent (IRON technique) provides an alternative fMRI method in animal models to improve sensitivity and spatial localization, the inherently slower hemodynamic IRF causes IRON detection efficiency to decrease faster than BOLD efficiency as the interstimulus interval (ISI) is shortened. Using simulations based upon assumptions of stimulus-response linearity and experimental data obtained in awake, non-human primates, this study compared detection efficiencies for fixed, random and semi-random ISI distributions for BOLD and IRON techniques.
View Article and Find Full Text PDFIron oxide contrast agents have been employed extensively in anesthetized rodents to enhance fMRI sensitivity and to study the physiology of cerebral blood volume (CBV) in relation to blood oxygen level-dependent (BOLD) signal following neuronal activation. This study quantified the advantages of exogenous agent for repeated neuroimaging in awake, nonhuman primates using a clinical 3 Tesla scanner. A monocrystalline iron oxide nanoparticle (MION) solution was injected at iron doses of 8 to 10 mg/kg in two macaque monkeys.
View Article and Find Full Text PDF