Publications by authors named "Francesco Tricarico"

The evaluation of pulmonary veins during cross-sectional imaging of the chest and the knowledge of their embryology and anatomy are useful for detecting congenital conditions that may be clinically significant. Moreover, with the spread of cross-sectional imaging it is very frequent to find anatomical variants; therefore the radiologist should easily recognize their appearances. This case report shows a left-side upper partial anomalous pulmonary venous return (PAPVR) through a "curved" vein that joins the left brachiocephalic vein, in a female patient who underwent whole-body computed tomography (CT) for staging endometrial cancer.

View Article and Find Full Text PDF

Disparities in the risk of coronary artery disease (CAD) between races may be influenced by differences in the thoracic adipose tissue. We compared computed tomography (CT)-derived volumes of epicardial adipose tissue (EAT), mediastinal adipose tissue (MAT), and pericoronary fat thickness (PFT) and correlations with CAD between black and white patients. This institutional review board-approved Health Insurance Portability and Accountability Act-compliant study included 372 age- and gender-matched black versus white patients (186 black, 54 ± 11 years, 50% men; 186 white, 54 ± 11 years, 50% men) who underwent CT for chest pain evaluation.

View Article and Find Full Text PDF

Chest pain associated with cocaine use represents an increasing problem in the emergency department (ED). Cocaine use has been linked to the acute coronary syndrome (ACS) and acute myocardial infarction (AMI). We used coronary computed tomography angiography (cCTA) to evaluate the prevalence, severity and composition of atherosclerotic lesions in cocaine users.

View Article and Find Full Text PDF

Significant literature on MDCT coronary angiography (MDCT-CA) has emerged in the last decade concerning patient's selection, technical aspects of different generations of CT equipment, ECG gating, contrast material and beta-blockade administration, acquisition parameters, and radiation dose. However, the literature regarding postprocessing, reading, and reporting is not so extensive. This review highlights the main elements of MDCT-CA data analysis, thereby allowing the radiologist to take full advantage of this technology and enable a structured report to be generated, promoting best practice with high-quality results.

View Article and Find Full Text PDF

Objectives: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions.

Methods: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE.

View Article and Find Full Text PDF

Objective: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment.

Materials And Methods: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.

View Article and Find Full Text PDF

Objectives: Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data.

Methods: Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector.

View Article and Find Full Text PDF

An experimental investigation was carried out to study the evolution of the volatile compounds of ripened sausages as a function of both storage time (time) and composition of packaging atmosphere (MAP). Ripened sausages, prepared at an industrial plant, were packed applying three different atmosphere compositions and were stored for three months. The obtained data evinced that the evolution of the volatile compounds was significantly related to the variable time more than to the variable MAP.

View Article and Find Full Text PDF