Background: The purpose of our study is to assess the short-term technical success and the safety of the Indigo System in a series of patients undergoing vacuum-assisted catheter direct thrombus aspiration (IS-CDTA) for acute lower limb ischemia (ALLI) and to evaluate which parameters may affect the outcome.
Methods: All procedures using the IS-CDTA for ALLI, performed in a single-centre Interventional Radiology Unit from February 2016 to March 2020, were retrospectively analysed. Technical success was defined as the achievement of nearly-complete or complete revascularization (TIPI grade 2/3) and considered as a good outcome.
Purpose: To retrospectively assess the efficacy and safety of FemoSeal vascular closure device to achieve hemostasis following antegrade common femoral artery puncture after lower limb revascularization using vascular sheaths from 5 to 8 Fr.
Methods: We reviewed the hemostatic outcome achieved with FemoSeal in 103 consecutive patients (mean age: 69 ± 8 years, 71 males) that undergone to 111 antegrade common femoral artery accesses for percutaneous lower limbs revascularization using 5- to 8-Fr vascular sheaths. We used FemoSeal in an unselected population, without exclusion criteria.
Southern forests are at the highest ozone (O3) risk in Europe where ground-level O3 is a pressing sanitary problem for ecosystem health. Exposure-based standards for protecting vegetation are not representative of actual field conditions. A biologically-sound stomatal flux-based standard has been proposed, although critical levels for protection still need to be validated.
View Article and Find Full Text PDFAims: The need of adenosine administration for the achievement of maximal hyperaemia limits the widespread application of fractional flow reserve (FFR) in the real world. We hypothesised that Pd/Pa ratio registered during submaximal reactive hyperaemia induced by conventional non-ionic radiographic contrast medium (contrast medium induced Pd/Pa ratio: CMR) can be sufficient for the assessment of physiological severity of stenosis in the vast majority of cases. The aim of the present study was to test the accuracy of CMR in comparison to FFR.
View Article and Find Full Text PDFEuroIntervention
July 2015
Aims: Despite the fact that fractional flow reserve (FFR) is better than angiography in guiding PCI, in the real world the choice to perform PCI is generally based on angiography. Three-dimensional quantitative coronary angiography (3D-QCA) may increase the accuracy of angiography, especially in intermediate coronary artery stenosis (ICAS). The aim of the study was to assess the best cut-off values of area stenosis % (AS%) and the extent of jeopardised myocardium for predicting FFR and for excluding the need to perform FFR.
View Article and Find Full Text PDFEnviron Pollut
October 2008
Treatments with ethylenediurea (EDU) protect plants from ozone foliar injury, but the processes underlying this protection are poorly understood. Adult ash trees (Fraxinus excelsior), with or without foliar ozone symptoms in previous years, were treated with EDU at 450 ppm by gravitational trunk infusion in May-September 2005 (32.5 ppm h AOT40).
View Article and Find Full Text PDFAdult ash trees (Fraxinus excelsior L.), known to be sensitive or tolerant to ozone, determined by presence or absence of foliar symptoms in previous years, were treated with ethylenediurea (EDU) at 450 ppm by gravitational trunk infusion over the 2005 growing season (32.5 ppm h AOT40).
View Article and Find Full Text PDF