Background And Purpose: Radiotherapy plans with excessive complexity exhibit higher uncertainties and worse patient-specific quality assurance (PSQA) results, while the workload of measurement-based PSQA can impact the efficiency of the radiotherapy workflow. Machine Learning (ML) and Lean Six Sigma, a process optimization method, were implemented to adopt a targeted PSQA approach, aiming to reduce workload, risk of failures, and monitor complexity.

Materials And Methods: Lean Six Sigma was applied using DMAIC (define, measure, analyze, improve, and control) steps.

View Article and Find Full Text PDF

Background: Total marrow (lymphoid) irradiation (TMI/TMLI) is a radiotherapy treatment used to selectively target the bone marrow and lymph nodes in conditioning regimens for allogeneic hematopoietic stem cell transplantation. A complex field geometry is needed to cover the large planning target volume (PTV) of TMI/TMLI with volumetric modulated arc therapy (VMAT). Five isocenters and ten overlapping fields are needed for the upper body, while, for patients with large anatomical conformation, two specific isocenters are placed on the arms.

View Article and Find Full Text PDF

This study quantified the incidental dose to the first axillary level (L1) in locoregional treatment plan for breast cancer. Eighteen radiotherapy centres contoured L1-L4 on three different patients (P1,2,3), created the L2-L4 planning target volume (single centre planning target volume, SC-PTV) and elaborated a locoregional treatment plan. The L2-L4 gold standard clinical target volume (CTV) along with the gold standard L1 contour (GS-L1) were created by an expert consensus.

View Article and Find Full Text PDF

Background: Hypo-fractionation can be an effective strategy to lower costs and save time, increasing patient access to advanced radiation therapy. To demonstrate this potential in practice within the context of temporal evolution, a twenty-year analysis of a representative radiation therapy facility from 2003 to 2022 was conducted. This analysis utilized comprehensive data to quantitatively evaluate the connections between advanced clinical protocols and technological improvements.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to evaluate the clinical outcomes of a large series of brain metastatic renal cell carcinoma (BMRCC) patients treated in three Italian centers.

Methods: A total of 120 BMRCC patients with a total of 176 lesions treated were evaluated. Patients received surgery plus postoperative HSRS, single-fraction SRS, or hypofractionated SRS (HSRS).

View Article and Find Full Text PDF
Article Synopsis
  • A phase III randomized trial compared the effectiveness of linac-based stereotactic radiosurgery (SRS) to a multi-source gamma-ray system for treating brain metastases in adults with solid tumors.
  • The primary focus was on the incidence of symptomatic radionecrosis, while secondary outcomes included local progression, distant brain failure, and overall survival.
  • Results showed no significant difference in outcomes between the two methods, with both presenting similar rates of symptomatic radionecrosis and other complications despite variations in treatment times.
View Article and Find Full Text PDF

Background: To analyze RapidPlan knowledge-based models for DVH estimation of organs at risk from breast cancer VMAT plans presenting arc sectors en-face to the breast with zero dose rate, feature imposed during the optimization phase (avoidance sectors AS).

Methods: CT datasets of twenty left breast patients in deep-inspiration breath-hold were selected. Two VMAT plans, PartArc and AvoidArc, were manually generated with double arcs from ~ 300 to ~ 160°, with the second having an AS en-face to the breast to avoid contralateral breast and lung direct irradiation.

View Article and Find Full Text PDF

Objectives: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV).

Methods: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them.

View Article and Find Full Text PDF

Introduction: Hepatocellular Carcinoma (HCC) is characterized, in Western countries, by higher incidence and mortality rates in the older adult population. In frail patients, limited therapeutic resources are available due to limited expected benefit concerning the risk of treatment-related toxicity. The aim of our study is to evaluate the role of Stereotactic Body Radiotherapy (SBRT) in the clinical management of older old adults (age ≥ 80 years) HCC patients and to identify predictors of efficacy and toxicity.

View Article and Find Full Text PDF

Purpose: Failure mode effect analysis (FMEA) is a proactive methodology that allows one to analyze a process, regardless of whether an adverse event occurs. In our radiation therapy (RT) department, a first FMEA was performed in 2009. In this paper we critically re-evaluate the RT process after 10 years and present it in terms of a lesson learned.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to evaluate the impact of breast size on long-term toxicity and cosmesis in patients with breast cancer treated with hypofractionated simultaneous integrated boost (SIB) using volumetric modulated arc therapy (VMAT).

Patients And Methods: Patients with early stage breast cancer were treated with 3-week hypofractionated SIB-VMAT to the whole breast (40.5 Gy) and tumor bed (48 Gy).

View Article and Find Full Text PDF

Background: PRIMO is a graphical environment based on PENELOPE Monte Carlo (MC) simulation of radiotherapy beams able to compute dose distribution in patients, from plans with different techniques. The dosimetric characteristics of an HD-120 MLC (Varian), simulated using PRIMO, were here compared with measurements, and also with Acuros calculations (in the Eclipse treatment planning system, Varian).

Materials And Methods: A 10 MV FFF beam from a Varian EDGE linac equipped with the HD-120 MLC was used for this work.

View Article and Find Full Text PDF

Purpose: To appraise the ability of a radiomics signature to predict clinical outcome after stereotactic body radiation therapy (SBRT) for pancreas carcinoma.

Methods: A cohort of 100 patients was included in this retrospective, single institution analysis. Radiomics texture features were extracted from computed tomography (CT) images obtained for the clinical target volume.

View Article and Find Full Text PDF

Background: To appraise the ability of a radiomics based analysis to predict local response and overall survival for patients with hepatocellular carcinoma.

Methods: A set of 138 consecutive patients (112 males and 26 females, median age 66 years) presented with Barcelona Clinic Liver Cancer (BCLC) stage A to C were retrospectively studied. For a subset of these patients (106) complete information about treatment outcome, namely local control, was available.

View Article and Find Full Text PDF

Purpose: The increasing interest in SBRT treatments encourages the use of flattening filter free (FFF) beams. Aim of this work was to evaluate the performance of the PTW60019 microDiamond detector under 6MV and 10MVFFF beams delivered with the EDGE accelerator (Varian Medical System, Palo Alto, USA). A flattened 6MV beam was also considered for comparison.

View Article and Find Full Text PDF

Objective: Breast planning with volumetric modulated arc therapy (VMAT) has been explored, especially for left-sided breast treatments, with the primary intent of lowering the heart dose and improving target dose homogeneity. As a trade-off, larger healthy tissue volumes would receive low dose levels, with the potential risk of increasing late toxicities and secondary cancer induction, although no clinical data are available today to confirm the risk level. The scope of this work is to explore the dosimetric trade-offs using two different VMAT plans.

View Article and Find Full Text PDF

Purpose: Small field measurements are challenging, due to the physical characteristics coming from the lack of charged particle equilibrium, the partial occlusion of the finite radiation source, and to the detector response. These characteristics can be modeled in the dose calculations in the treatment planning systems. Aim of the present work is to evaluate the MU calculation accuracy for small fields, defined by jaw or MLC, for anisotropic analytical algorithm (AAA) and Acuros XB algorithms, relative to output measurements on the beam central axis.

View Article and Find Full Text PDF

Background: To report toxicity and early clinical outcomes of hypofractionated simultaneous integrated boost (SIB) approach with Volumetric Modulated Arc Therapy (VMAT) as adjuvant treatment after breast-conserving surgery.

Methods: Patients presenting early-stage breast cancer were enrolled in a phase II trial.

Eligibility Criteria: age > 18 years old, invasive cancer or ductal carcinoma in situ (DCIS), Stage I-II (T < 3 cm and N ≤ 3), breast-conserving surgery without oncoplastic reconstruction.

View Article and Find Full Text PDF

The IBA Razor diode supersedes the IBA SFD and is intended for use in small fields. However, its behaviour in small fields has not yet been quantified. In this work, we examine the response of the Razor diode against the air core scintillation dosimeter (FOD) and Gafchromic film in photon beams from three Varian linac beams.

View Article and Find Full Text PDF

Background: To assess the impact of volumetric-modulated arc therapy (VMAT) compared with 3D-conformal radiotherapy (3DCRT) in patients with newly diagnosed high grade glioma in terms of toxicity, progression free survival (PFS) and overall survival (OS).

Methods: From March 2004 to October 2014, 341 patients underwent surgery followed by concomitant and adjuvant chemo-radiotherapy. From 2003 to 2010, 167 patients were treated using 3DCRT; starting from 2011, 174 patients underwent VMAT.

View Article and Find Full Text PDF

Purpose: To characterize the performance of a new unshielded silicon diode (Razor-IBA) for dose measurements in small flattening filter free beams.

Methods: The Razor has an active volume of 0.6 mm in diameter and 20 µm in length.

View Article and Find Full Text PDF

Purpose: To evaluate the performance of a model-based optimisation process for volumetric modulated arc therapy, VMAT, applied to whole breast irradiation.

Methods And Materials: A set of 150 VMAT dose plans with simultaneous integrated boost were selected to train a model for the prediction of dose-volume constraints. The dosimetric validation was done on different groups of patients from three institutes for single (50 cases) and bilateral breast (20 cases).

View Article and Find Full Text PDF

Objective: New linear accelerators can be equipped with a 6D robotic couch, providing two additional rotational motion axes: pitch and roll. These shifts in kilo voltage-cone beam CT (kV-CBCT) image-guided radiotherapy (IGRT) were evaluated over the first 6 months of usage of a 6D robotic couch-top, ranking the treatment sites for which the two compensations are larger for patient set-up.

Methods: The couch compensations of 2945 fractions for 376 consecutive patients treated on the PerfectPitch™ 6D couch (Varian(®) Medical Systems, Palo Alto, CA) were analysed.

View Article and Find Full Text PDF

Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system.

Methods: Detector output ratios (DORs) for 4 and 8 mm beams were measured using a microDiamond (PTW-60019), a stereotactic unshielded diode [IBA stereotactic field detector (SFD)], a shielded diode (IBA photon field detector), and GafChromic EBT3 films. Both parallel and transversal acquisition directions were considered for PTW-60019 measurements.

View Article and Find Full Text PDF

To investigate the role of hypo-fractionated stereotactic radiation treatment (HSRT) in the management of skull base meningioma. Twenty-six patients were included in the study and treated with a dose of 30 Gy in 5 fractions with volumetric modulated arc therapy (RapidArc). Eighteen patients were symptomatic before treatment.