Publications by authors named "Francesca Ferrulli"

A Cs2LiYCl6:Ce crystal, enriched in 6Li to > 95% (CLYC-6), was investigated for thermal neutron detection: it was characterised in terms of intrinsic efficiency and γ-ray discrimination capability and compared with a 3He counter (partial 3He pressure 2.3 atm). The intrinsic efficiency was determined by irradiating the detectors with thermal neutrons.

View Article and Find Full Text PDF

The Maastro Proton Therapy Centre is the first European facility housing the Mevion S250i Hyperscan synchrocyclotron. The proximity of the accelerator to the patient, the presence of an active pencil beam delivery system downstream of a passive energy degrader and the pulsed structure of the beam make the Mevion stray neutron field unique amongst proton therapy facilities. This paper reviews the results of a rem-counter intercomparison experiment promoted by the European Radiation Dosimetry Group at Maastro and compares them with those at other proton therapy facilities.

View Article and Find Full Text PDF

Objective Proton therapy is gaining popularity because of the improved dose delivery over conventional radiation therapy. The secondary dose to healthy tissues is dominated by secondary neutrons. Commercial rem-counters are valuable instruments for the on-line assessment of neutron ambient dose equivalent (H*(10)).

View Article and Find Full Text PDF

This work presents the design, construction and experimental characterisation of a lightweight and low-cost thermal neutron assembly, to be used with the existing Am-Be source irradiator of CERN radiation Calibration Laboratory (Cal Lab). The assembly consists of a cylindrical moderator (18 cm diameter, 25.5 cm height and 5.

View Article and Find Full Text PDF

In July 2017, the International Commission on Radiation Units and Measurements (ICRU) and the International Commission on Radiological Protection (ICRP) proposed the introduction of new operational quantities for external radiation exposure, with the aim of improving coherence between protection quantities and operational quantities within the system of radiological protection. A change in operational quantities will impact both instrumentation and reference radiation fields used for their calibration. This paper evaluates the potential impact of the new quantity ambient dose, H*, meant to replace ambient dose equivalent, H*(10), on two neutron reference fields, the Am-Be source and the CERF high-energy workplace field, and on the response of two models of extended-range neutron rem counters (LINUS and LUPIN).